Plan Review Details - Permit 20020518
Plan Review Stops For Permit 20020518 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-03-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-11 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-11 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-06 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-02 |
Time |
10:31 |
Sent To |
|
|
Notes |
2020-03-06 11:01:19 | PLAN REVIEW - BUILDING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE VERTICAL RE-INFORCING FOR CMU IN-FILL PER | | FIGURE R606.11 (2) AND | | | | 2. DIGITAL SIGNATURE FAILED. SEE SIGNATURE REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-03-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-11 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-11 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-03-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-06 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-02 |
Time |
10:31 |
Sent To |
|
|
Notes |
2020-03-06 11:21:44 | PLAN REVIEW - ELECTRICAL | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. NO ISSUE TAKEN WITH PROPOSED SOW. | | | | 2. NEW PLAN SHEET REQUIRED - SIGNATURE/SEAL. | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-03-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-06 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-02-27 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2020-03-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-11 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-11 |
Time |
10:29 |
Sent To |
|
|
Notes |
2020-03-11 10:30:15 | PAPER PLAN SUBMITTED. CT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-03-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-06 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-02 |
Time |
10:31 |
Sent To |
|
|
Notes |
2020-03-06 11:04:15 | PLAN REVIEW - DIGITAL SIGNATURE AND SEAL | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | DIGIATAL SIGNATURE - | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | |
|
|
|