Plan Review Details - Permit 20020504
Plan Review Stops For Permit 20020504
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2020-02-21 Cont ID  
Sent By cpuell Date 2020-02-21 Time 15:03 Rev Time 0.00
Received By cpuell Date 2020-02-21 Time 15:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-08-11 Cont ID  
Sent By pvalenti Date 2020-08-11 Time 08:14 Rev Time 0.00
Received By pvalenti Date 2020-08-11 Time 08:14 Sent To  
Notes
2020-08-11 08:19:25PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 THE WIND LOADS MUST BE IN ACCORDANCE WITH FBC R
 301.2(2).
  
 NOTE: THE WIND LOAD REQUIREMENTS FROM THE FLORIDA
 BUILDING CODE SECTION R301.2(2) HAVE BEEN PLACED ON THE
 PLANS FOR CLARIFICATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-07-29 Cont ID  
Sent By pvalenti Date 2020-07-29 Time 16:16 Rev Time 0.00
Received By pvalenti Date 2020-07-29 Time 13:33 Sent To  
Notes
2020-07-29 16:00:09PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561?805?6673
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 2ND BUILDING REVIEW DENIED:
  
  
 4) FBC R FIGURE R 301.2(7), ON PAGES 3.0 AND 8.0, THE
 WIND LOAD SCHEDULE ZONES FOR ROOF AND WALLS DO NOT
 MATCH THE 2017 FLORIDA BUILDING CODE ZONES.
 (PLEASE CORRECT THE WINDLOAD SCHEDULE ZONES PER THE
 2017 FBC 6TH EDITION AS THE THE ZONES 2A ARE NOT 3A DO
 NOT MATCH WITH THIS CODE).
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-25 Cont ID  
Sent By pvalenti Date 2020-02-25 Time 10:02 Rev Time 0.00
Received By pvalenti Date 2020-02-25 Time 07:02 Sent To  
Notes
2020-02-25 10:51:19***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 1) FBC B 107.2.1, THE COVER PAGE CLASSIFIES THE
 OCCUPANCY AS R-2. THIS NEEDS TO BE CHANGED TO R-3.
  
 2) FBC R 310.2.1, PAGE 4.0 EGRESS WINDOW DETAIL SHOWS A
 MINIMUM CLEAR HEIGHT OF 22". THIS NEEDS TO BE CHANGED
 TO 24".
  
 3) FBC B 107.2.1, PAGES 9.0, 10.0, & 11.0 DO NOT
 IDENTIFY THE LOCATION OF BATHROOM DOOR/ENTRY. PLEASE
 SHOW ON PLANS.
  
 4) FBC R FIGURE R 301.2(7), ON PAGES 3.0 AND 8.0, THE
 WIND LOAD SCHEDULE ZONES FOR ROOF AND WALLS DO NOT
 MATCH THE 2017 FLORIDA BUILDING CODE ZONES.
  
 5) FBC B 107.2.1, THE WIND LOAD SCHEDULE ON PAGE 8.0
 REFERS TO THE 2014 FLORIDA BUILDING CODE, THIS NEEDS TO
 BE CHANGED TO THE 2017 FLORIDA BUILDING CODE.
  
 6) FBC B 107.2.1, ON PAGE 6.0 DETAIL #1, THE ROOF PITCH
 IS IDENTIFIED AS 6:12, ALL OTHER DETAILS ON PLANS SHOW
 THE ROOF PITCH TO BE A 5:12. PLEASE CLARIFY THE
 LOCATION OF 6:12 PITCH DETAIL.
  
 7) FBC B 107.2.1 THE SUBMITTED PRODUCT APPROVAL FOR
 SLIDING GLASS DOOR (14-1103.02) HAS EXPIRED. ON PAGE
 3.0 THE DOOR SCHEDULE IDENTIFIES THIS DOOR AS # 3, ON
 THE FLOOR PLAN DOOR #3 IS FOR AN EXTERIOR SWINGING DOOR
 NOT A SLIDING GLASS DOOR.PLEASE CORRECT THE DOOR
 SCHEDULE AND SUBMIT THE CORRECT(REVIEW STAMPED) PRODUCT
 APPROVAL FOR THIS LOCATION.
  
 8) FBC B 107.2.1, THE SLIDING GLASS DOOR IDENTIFIED AS
 DOOR # 2, PRODUCT APPROVAL # 17-0504.01 WAS NOT
 SUBMITTED. PLEASE PROVIDE THE REVIEW STAMPED PRODUCT
 APPROVAL.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-03-09 Cont ID  
Sent By jpearson Date 2020-03-09 Time 13:21 Rev Time 0.00
Received By jpearson Date 2020-03-09 Time 07:43 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-05 Cont ID  
Sent By pvalenti Date 2020-08-05 Time 16:34 Rev Time 0.00
Received By pvalenti Date 2020-07-18 Time 09:12 Sent To  
Notes
2020-07-18 09:51:41R13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-03-09 Time   Rev Time 0.00
Received By lmarchan Date 2020-02-12 Time 13:34 Sent To  
Notes
2020-02-13 13:35:19R13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-02-26 Cont ID  
Sent By pvalenti Date 2021-02-26 Time 14:38 Rev Time 0.00
Received By pvalenti Date 2021-02-26 Time 14:38 Sent To  
Notes
2021-02-26 14:45:32****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 COUNTY IMPACT FEE REVIEW APPROVED:
  
 RECEIPT # 2021-0226-9
 MU-2020035959-0000
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-02-25 Cont ID  
Sent By pvalenti Date 2020-02-25 Time 13:00 Rev Time 0.00
Received By pvalenti Date 2020-02-25 Time 13:00 Sent To  
Notes
2020-02-25 13:01:55***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 IMPACT FEES - PAPER SUBMITTALS
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-07-29 Cont ID  
Sent By pvalenti Date 2020-07-29 Time 16:22 Rev Time 0.00
Received By pvalenti Date 2020-07-29 Time 13:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-02-25 Cont ID  
Sent By pvalenti Date 2020-02-25 Time 11:28 Rev Time 0.00
Received By pvalenti Date 2020-02-25 Time 07:02 Sent To  
Notes
2020-02-25 11:41:00***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 MECHANICAL REVIEW DENIED:
  
 FBC M 601.6/FBC R M1602.3, THE RETURN AIR DUCT AND
 GRILLS IN THE MASTER BEDROOM ARE IDENTIFIED AS 10".
 PLEASE CHANGE THE SIZE TO 12" PER THE BALANCED AIR
 REQUIREMENTS OF THE FLORIDA BUILDING CODE..

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-03-02 Cont ID  
Sent By lcrespo Date 2020-02-28 Time 06:50 Rev Time 0.00
Received By lcrespo Date 2020-02-27 Time 07:34 Sent To  
Notes
2020-03-02 06:51:2802/28/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM
 [email protected]
 561-701-6437
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2020-07-29 Cont ID  
Sent By pvalenti Date 2020-07-29 Time 16:19 Rev Time 0.00
Received By pvalenti Date 2020-07-29 Time 13:33 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-02-25 Cont ID  
Sent By pvalenti Date 2020-02-25 Time 12:58 Rev Time 0.00
Received By pvalenti Date 2020-02-25 Time 12:58 Sent To  
Notes
2020-02-25 13:00:31***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 ROOFING REVIEW DENIED:
  
 FBC B 107, PROVIDE, REVIEW STAMPED, ROOFING MATERIAL
 PRODUCT APPROVALS.
  
 NOTE: A ROOFING SUB-PERMIT IS REQUIRED.

Review Stop Z ZONING
Rev No 3 Status P Date 2020-09-16 Cont ID  
Sent By awooten Date 2020-09-16 Time   Rev Time 0.00
Received By awooten Date 2020-09-16 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2020-08-05 Cont ID  
Sent By awooten Date 2020-08-05 Time   Rev Time 0.00
Received By awooten Date 2020-08-05 Time   Sent To  
Notes
2020-08-05 15:58:18*************************************ZONING REVIEW
 FAILED*************************************
  
 SINGLE FAMILY HOMES ARE REQUIRED TO PROVIDE TWO ON SITE
 PARKING SPACES. PLANS SHOW A 1 CAR GARAGE. A DRIVEWAY
 IS REQUIRED. DRIVEWAYS REQUIRE A SEPARATE PERMIT.
  
 LANDSCAPE PLAN MUST BE SUBMITTED SEPARATELY, UNDER
 LANDSCAPE PERMIT.
  
 AERIAL PHOTO ON PLANS SHOW 734 47TH STREET.
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2020-02-20 Cont ID  
Sent By awooten Date 2020-02-20 Time   Rev Time  
Received By awooten Date 2020-02-20 Time   Sent To  
Notes
2020-02-20 14:49:23*********************ZONING REVIEW
 FAILED*************************
  
 MAXIMUM BUILDING HEIGHT: IS 30 FEET. PLEASE CORRECT
 CODE NOTES ON SITE PLAN.
  
 NEW SINGLE FAMILY DEVELOPMENT TRIGGERS THE LANDSCAPING
 CODE. SUBMIT A SEPARATE LANDSCAPING AND IRRIGATION PLAN
 FOR PERMIT SHOWING THE FOLLOWING:
  
 RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
 SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS
 GROSS LOT SQUARE FOOTAGE MINUS
 BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
 ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
 ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]