Plan Review Stops For Permit 20020504 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2020-02-21 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-02-21 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-02-21 |
Time |
15:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-08-11 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-08-11 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-08-11 |
Time |
08:14 |
Sent To |
|
|
Notes |
2020-08-11 08:19:25 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | THE WIND LOADS MUST BE IN ACCORDANCE WITH FBC R | | 301.2(2). | | | | NOTE: THE WIND LOAD REQUIREMENTS FROM THE FLORIDA | | BUILDING CODE SECTION R301.2(2) HAVE BEEN PLACED ON THE | | PLANS FOR CLARIFICATION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-07-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-07-29 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-07-29 |
Time |
13:33 |
Sent To |
|
|
Notes |
2020-07-29 16:00:09 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561?805?6673 | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | 2ND BUILDING REVIEW DENIED: | | | | | | 4) FBC R FIGURE R 301.2(7), ON PAGES 3.0 AND 8.0, THE | | WIND LOAD SCHEDULE ZONES FOR ROOF AND WALLS DO NOT | | MATCH THE 2017 FLORIDA BUILDING CODE ZONES. | | (PLEASE CORRECT THE WINDLOAD SCHEDULE ZONES PER THE | | 2017 FBC 6TH EDITION AS THE THE ZONES 2A ARE NOT 3A DO | | NOT MATCH WITH THIS CODE). | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-02-25 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-02-25 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-02-25 |
Time |
07:02 |
Sent To |
|
|
Notes |
2020-02-25 10:51:19 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | 1) FBC B 107.2.1, THE COVER PAGE CLASSIFIES THE | | OCCUPANCY AS R-2. THIS NEEDS TO BE CHANGED TO R-3. | | | | 2) FBC R 310.2.1, PAGE 4.0 EGRESS WINDOW DETAIL SHOWS A | | MINIMUM CLEAR HEIGHT OF 22". THIS NEEDS TO BE CHANGED | | TO 24". | | | | 3) FBC B 107.2.1, PAGES 9.0, 10.0, & 11.0 DO NOT | | IDENTIFY THE LOCATION OF BATHROOM DOOR/ENTRY. PLEASE | | SHOW ON PLANS. | | | | 4) FBC R FIGURE R 301.2(7), ON PAGES 3.0 AND 8.0, THE | | WIND LOAD SCHEDULE ZONES FOR ROOF AND WALLS DO NOT | | MATCH THE 2017 FLORIDA BUILDING CODE ZONES. | | | | 5) FBC B 107.2.1, THE WIND LOAD SCHEDULE ON PAGE 8.0 | | REFERS TO THE 2014 FLORIDA BUILDING CODE, THIS NEEDS TO | | BE CHANGED TO THE 2017 FLORIDA BUILDING CODE. | | | | 6) FBC B 107.2.1, ON PAGE 6.0 DETAIL #1, THE ROOF PITCH | | IS IDENTIFIED AS 6:12, ALL OTHER DETAILS ON PLANS SHOW | | THE ROOF PITCH TO BE A 5:12. PLEASE CLARIFY THE | | LOCATION OF 6:12 PITCH DETAIL. | | | | 7) FBC B 107.2.1 THE SUBMITTED PRODUCT APPROVAL FOR | | SLIDING GLASS DOOR (14-1103.02) HAS EXPIRED. ON PAGE | | 3.0 THE DOOR SCHEDULE IDENTIFIES THIS DOOR AS # 3, ON | | THE FLOOR PLAN DOOR #3 IS FOR AN EXTERIOR SWINGING DOOR | | NOT A SLIDING GLASS DOOR.PLEASE CORRECT THE DOOR | | SCHEDULE AND SUBMIT THE CORRECT(REVIEW STAMPED) PRODUCT | | APPROVAL FOR THIS LOCATION. | | | | 8) FBC B 107.2.1, THE SLIDING GLASS DOOR IDENTIFIED AS | | DOOR # 2, PRODUCT APPROVAL # 17-0504.01 WAS NOT | | SUBMITTED. PLEASE PROVIDE THE REVIEW STAMPED PRODUCT | | APPROVAL. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-03-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-03-09 |
Time |
13:21 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-03-09 |
Time |
07:43 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-08-05 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-07-18 |
Time |
09:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-03-09 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-02-12 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-02-26 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2021-02-26 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2021-02-26 |
Time |
14:38 |
Sent To |
|
|
Notes |
2021-02-26 14:45:32 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | COUNTY IMPACT FEE REVIEW APPROVED: | | | | RECEIPT # 2021-0226-9 | | MU-2020035959-0000 | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-02-25 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-02-25 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-02-25 |
Time |
13:00 |
Sent To |
|
|
Notes |
2020-02-25 13:01:55 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-07-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-07-29 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-07-29 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-02-25 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-02-25 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-02-25 |
Time |
07:02 |
Sent To |
|
|
Notes |
2020-02-25 11:41:00 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | MECHANICAL REVIEW DENIED: | | | | FBC M 601.6/FBC R M1602.3, THE RETURN AIR DUCT AND | | GRILLS IN THE MASTER BEDROOM ARE IDENTIFIED AS 10". | | PLEASE CHANGE THE SIZE TO 12" PER THE BALANCED AIR | | REQUIREMENTS OF THE FLORIDA BUILDING CODE.. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-03-02 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-02-28 |
Time |
06:50 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-02-27 |
Time |
07:34 |
Sent To |
|
|
Notes |
2020-03-02 06:51:28 | 02/28/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM | | [email protected] | | 561-701-6437 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-07-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-07-29 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-07-29 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-02-25 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-02-25 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-02-25 |
Time |
12:58 |
Sent To |
|
|
Notes |
2020-02-25 13:00:31 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | ROOFING REVIEW DENIED: | | | | FBC B 107, PROVIDE, REVIEW STAMPED, ROOFING MATERIAL | | PRODUCT APPROVALS. | | | | NOTE: A ROOFING SUB-PERMIT IS REQUIRED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-09-16 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2020-09-16 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-08-05 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2020-08-05 |
Time |
|
Sent To |
|
|
Notes |
2020-08-05 15:58:18 | *************************************ZONING REVIEW | | FAILED************************************* | | | | SINGLE FAMILY HOMES ARE REQUIRED TO PROVIDE TWO ON SITE | | PARKING SPACES. PLANS SHOW A 1 CAR GARAGE. A DRIVEWAY | | IS REQUIRED. DRIVEWAYS REQUIRE A SEPARATE PERMIT. | | | | LANDSCAPE PLAN MUST BE SUBMITTED SEPARATELY, UNDER | | LANDSCAPE PERMIT. | | | | AERIAL PHOTO ON PLANS SHOW 734 47TH STREET. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-02-20 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-02-20 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2020-02-20 |
Time |
|
Sent To |
|
|
Notes |
2020-02-20 14:49:23 | *********************ZONING REVIEW | | FAILED************************* | | | | MAXIMUM BUILDING HEIGHT: IS 30 FEET. PLEASE CORRECT | | CODE NOTES ON SITE PLAN. | | | | NEW SINGLE FAMILY DEVELOPMENT TRIGGERS THE LANDSCAPING | | CODE. SUBMIT A SEPARATE LANDSCAPING AND IRRIGATION PLAN | | FOR PERMIT SHOWING THE FOLLOWING: | | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | GROSS LOT SQUARE FOOTAGE MINUS | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|