Plan Review Stops For Permit 20020338 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2020-03-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-27 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-27 |
Time |
07:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-03-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-20 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-20 |
Time |
13:31 |
Sent To |
|
|
Notes |
2020-03-20 13:35:06 | PARKING LOT STRIPPING - | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - | | 1) PLEASE SHOW THE PARKING SPACE ACCESS AISLE LOCATION | | AND SIZES TO COMPLY WITH FBC ACCESSIBILITY 502.3 (NEEDS | | TO BE 5 FOOT WIDE AND RUN ALONG SIDE THE PARKING SPACE | | FOR THE FULL LENGTH OF THE PARKING SPACE - 18 FEET | | LONG) THE CROSS HATCHED AREA FOR THE ACCESS AISLE NEEDS | | TO BE 5 FOOT WIDE AND 18 FT LONG - RUNNING ALONG SIDE | | THE PARKING SPACE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-17 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-17 |
Time |
11:06 |
Sent To |
|
|
Notes |
2020-03-17 11:13:12 | PARKING LOT STRIPPING - | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - | | 1) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZES TO COMPLY | | WITH FBC ACCESSIBILITY 502.2 (NEEDS TO BE 12 FOOT WIDE) | | 2) PLEASE SHOW THE PARKING SPACE ACCESS AISLE LOCATION | | SIZES TO COMPLY WITH FBC ACCESSIBILITY 502.3 (NEEDS TO | | BE 5 FOOT WIDE AND RUN ALONG SIDE THE PARKING SPACE FOR | | THE FULL LENGTH OF THE PARKING SPACE) | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-02-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-02-26 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-02-26 |
Time |
15:57 |
Sent To |
|
|
Notes |
2020-02-26 16:09:50 | PARKING LOT STRIPPING - | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - | | 1) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZES TO COMPLY | | WITH FBC ACCESSIBILITY 502.2 | | 2) PLEASE SHOW THE PARKING SPACE ACCESS AISLE LOCATION | | SIZES TO COMPLY WITH FBC ACCESSIBILITY 502.3 | | 3) CANNOT HAVE A RAMP IN THE PARKING ACCESS AISLE - SEE | | FBC ACCESSIBILITY 502.4 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-03-26 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2020-03-26 |
Time |
|
Sent To |
|
|
Notes |
2020-03-26 11:06:01 | PASSED WITH PROVISOS: | | | | 1 - CONSTRUCT DRIVEWAY APRON IN COMPLIANCE WITH WPB | | CONSTRUCTION STANDARD DETAIL GC-5 (WHEN DISTANCE | | BETWEEN CURB OR EDGE OF PAVEMENT IS 10 FT. OR GREATER), | | OR STANDARD DETAIL GC-6 (WHEN DISTANCE BETWEEN CURB OR | | EDGE OF PAVEMENT IS LESS THAN 10 FT.) EMAIL | | [email protected] FOR STANDARD DETAILS IF NEEDED. | | | | 2 - THERE ARE WATER AND SEWER LINES IN THE VICINITY OF | | THIS PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE | | STATUTES, YOU MUST CALL 811 FOR UTILITY LOCATES AT | | LEAST TWO FULL BUSINESS DAYS IN ADVANCE OF ANY | | CONSTRUCTION OR DEMOLITION WORK. MORE INFORMATION CAN | | BE FOUND HERE: HTTP://WWW.SUNSHINE811.COM/ | | | | 3 ? PROTECT ALL NEARBY DRAINAGE INLETS/CATCH BASINS | | WITH STANDARD BEST MANAGEMENT PRACTICES - INLET SACKS, | | ETC. | | | | 4 - PLEASE ADDRESS ANY COMMENTS FROM OTHER REVIEWING | | DEPARTMENTS. | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | CONCERNS, THANKS. | | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR WPB, FL 33401 (MAILING | | ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 DIRECT: (561) 494-1098 | | FAX: (561) 494-1116 MOBILE: (561) 246-9525 | | EMAIL: [email protected] WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-03-19 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2020-03-19 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2020-03-12 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-03-12 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2020-03-12 |
Time |
|
Sent To |
I |
|
Notes |
2020-03-12 10:21:25 | PLEASE ADDRESS ZONING COMMENTS. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2020-02-19 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-02-19 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2020-02-19 |
Time |
|
Sent To |
I |
|
Notes |
2020-02-19 08:01:36 | PLEASE ADDRESS ZONING COMMENTS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-03-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-27 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-24 |
Time |
13:25 |
Sent To |
|
|
Notes |
2020-03-27 07:41:53 | PLANS TAKEN TO PERMIT LIBRARY | 2020-03-26 15:12:08 | ROUTED TO ROGER MCPHERSON DESK | 2020-03-25 13:31:23 | ROUTED TO ENG INBOX | 2020-03-24 13:25:09 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-03-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-20 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-17 |
Time |
09:43 |
Sent To |
|
|
Notes |
2020-03-20 13:35:38 | PLANS TAKEN TO PERMIT LIBRARY | 2020-03-19 11:35:07 | 3/19 GIVEN TO RMCPHERSON | 2020-03-18 16:11:23 | 3/18 ROUTED TO ENGINEERING INBOX | 2020-03-18 09:43:25 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-17 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-03 |
Time |
13:43 |
Sent To |
|
|
Notes |
2020-03-17 11:17:09 | PLANS TAKEN TO PERMIT LIBRARY | 2020-03-12 10:20:34 | 3/12 ROUTED TO BLDG MISC 2 | 2020-03-11 15:31:51 | 3/11 RESUB ROUTED TO ENGINEERING INBOX | 2020-03-04 13:43:18 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-02-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-02-26 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-02-10 |
Time |
13:38 |
Sent To |
|
|
Notes |
2020-02-26 16:13:55 | PLANS TO PERMIT LIBRARY | | | 2020-02-19 18:43:41 | ROUTED TO MISC 2 INBOX | 2020-02-18 11:28:11 | ROUTED TO ENGINEERING INBOX | 2020-02-11 13:38:59 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2020-03-25 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-03-25 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-03-25 |
Time |
10:05 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2020-03-18 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-03-18 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-03-18 |
Time |
12:23 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2020-03-11 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-03-11 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-03-11 |
Time |
11:49 |
Sent To |
I |
|
Notes |
2020-03-11 11:49:03 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 3/11/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. REVISE THE SIZE OF THE HANDICAP STALLS TO COMPLY | | WITH ZONING REGULATIONS. | | PURSUANT ZLDR SEC. 94-485(O)(2)(B), DIAGONAL OR | | PERPENDICULAR PARKING SPACES SHALL BE A MINIMUM OF 12 | | FEET WIDE AND 18 FEET LONG. | | | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1442 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-02-18 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-02-18 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-02-18 |
Time |
09:13 |
Sent To |
I |
|
Notes |
2020-02-18 09:14:38 | 2/18/20 FAILED. | | | | PLEASE SHOW THE DIMENSIONS OF THE HANDICAP SPACES TO | | COMPLY WITH ZONING REGULATIONS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | DEVELOPMENT SERVICES DEPARTMENT | | E-MAIL: [email protected] | | TEL: (561) 822-1442 | | |
|
|