Plan Review Stops For Permit 20020275 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-05-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-28 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-27 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-30 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-27 |
Time |
16:23 |
Sent To |
|
|
Notes |
2020-03-30 11:43:25 | PLAN REVIEW - BUILDING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PLAN APPEARS CODE COMPLIANT. | | | | 2. DIGITAL SIGNATURE AND SEAL IS INVALID. | | | | DIGITAL SIGNATURE IS NOT ISSUED IN A MANNER WHICH IS | | ACCEPTABLE TO EITHER FBPE OR FLORIDA BOARD OF | | PROFESSIONAL ENGINEERS. THIS TYPE OF SELF CERTIFICATION | | IS NOT INTENDED TO BE USED FOR PROFESSIONAL PURPOSES. | | THIRD PARTY CERTIFICATION IS REQUIRED. | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-02-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-02-22 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-02-14 |
Time |
08:33 |
Sent To |
|
|
Notes |
2020-02-22 08:28:20 | PLAN REVIEW - BUILDING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE STRUCTURAL DETAIL FOR NEW OPENING IN | | EXTERIOR WALL FOR RE-LOCATION OF FRENCH DOORS. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 2. PROVIDE STRUCTURAL DETAIL FOR IN-FILL OF STRUCTURAL | | WALL FOR REMOVAL OF FRENCH DOORS. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 3. PROVIDE PRODUCT APPROVALS OR SITE SPECIFIC | | ENGINEERING FOR RE-LOCATED FRENCH DOORS. | | PROVIDE PRODUCT APPROVALS | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | 4. ROOFING PERMIT REQUIRED. | | PERMITS | | 105.1 REQUIRED. | | | | 5. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | SYSTEM COMPONENTS. | | PROVIDE PRODUCT APPROVALS | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | 6. PLUMBING PERMIT REQUIRED. RE-LOCATION OF WATER | | HEATER. | | PERMITS | | 105.1 REQUIRED. | | | | 7. PROVIDE PLUMBING PLAN FOR RE-LOCATION OF WATER | | HEATER. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 8. PROVIDE SURVEY/SITE PLAN. | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-04-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-04-24 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-04-24 |
Time |
13:28 |
Sent To |
|
|
Notes |
2020-04-24 13:29:47 | NOT ABLE TO VERIFY SIGNATURE JLEAHY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2020-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-30 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-30 |
Time |
08:19 |
Sent To |
|
|
Notes |
2020-03-30 11:39:30 | PLAN REVIEW - ELECTRICAL | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PLAN IS CODE COMPLIANT. | | | | 2. DIGITAL SIGNATURE AND SEAL IS INVALID. | | | | DIGITAL SIGNATURE IS NOT ISSUED IN A MANNER WHICH IS | | ACCEPTABLE TO EITHER FBPE OR FLORIDA BOARD OF | | PROFESSIONAL ENGINEERS. THIS TYPE OF SELF CERTIFICATION | | IS NOT INTENDED TO BE USED FOR PROFESSIONAL PURPOSES. | | THIRD PARTY CERTIFICATION IS REQUIRED. | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-02-13 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-02-13 |
Time |
20:30 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-02-13 |
Time |
10:31 |
Sent To |
|
|
Notes |
2020-02-13 20:30:04 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. GARAGE DOOR OPENER RECEPTACLE REQUIRES GFCI | | PROTECTION THAT IS READILY ACCESSIBLE. NEC 210.8 | | | | 2. ATLEAST ONE GFCI RECEPTACLE OUTLET MUST BE INSTALLED | | PER CAR SPACE IN GARAGE. NEC 210.52G1 | | | | 3. DIGITALLY SUBMITTED PLANS MUST BE DIGITALLY SIGNED | | BY DESIGN PROFESSIONAL. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
N |
Date |
2020-05-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-04 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-04 |
Time |
10:48 |
Sent To |
|
|
Notes |
2020-05-04 10:48:56 | GAS SHALL BE BY SEPERATE PERMIT. CT |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2020-04-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-28 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-27 |
Time |
15:06 |
Sent To |
|
|
Notes |
2020-04-28 09:45:09 | PLAN REVIEW - GAS | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | | 3RD REVIEW | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY HAVE ADDITIONAL COMMENTS IN PARENTHESES. | | ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. FBC 107.2.1 PROVIDE COMPLETE INSTALLATION PLAN | | DRAWING FOR RELOCATION OF EXISTING GAS WATER HEATER, | | INCLUDING GAS RISER DIAGRAM INCLUDING ANY OTHER | | EXISTING APPLIANCES AND BTUH VALUES, PIPE SIZING | | CRITERIA, WHERE EXISTING IS LOCATED, EXISTING PIPING ON | | PLAN, HOW IT IS TO BE RE ROUTED, PIPING MATERIALS AND | | VALVING, CONFIRM THE EXISTING WATER HEATER IS FOR | | OUTDOOR INSTALLATION AND SUBMIT WATER HEATER | | INSTALLATION MANUAL. THIS IS A SECOND REQUEST. NOT | | ADDRESSED | | | | 2. FBC 107.2.1 NOTE ON DRAWING SAYS SEE ATTACHED SPEC | | FOR EXISTING WATER HEATER AND I FIND NONE UPLOADED TO | | THE PROJECT FOR REVIEW. CORRECTED | | | | 3. FBC FUEL GAS SECTION 404. PLEASE NOT THAT PIPING IN | | CONCEALED LOCATIONS SHALL NOT HAVE UNIONS, TUBING | | FITTINGS, RIGHT AND LEFT COUPLINGS, BUSHINGS, | | COMPRESSION COUPLINGS AND SWING JOINTS MADE BY | | COMBINATIONS OF FITTINGS UNLESS THE FITTINGS ARE LISTED | | FOR USE IN CONCEALED LOCATIONS. ADVISORY ONLY - NO | | ACTION REQUIRED | | | | ORIGINAL REVIEW BY: | | | | REVIEWED REMOTELY BY JAMES BAKER, PE | | PX3997, PE77268 | | 561-805-6724 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2020-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-30 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-30 |
Time |
08:52 |
Sent To |
|
|
Notes |
2020-03-30 11:13:22 | PLAN REVIEW - GAS | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | | 1ST REVIEW | | | | 1. FBC 107.2.1 PROVIDE COMPLETE INSTALLATION PLAN | | DRAWING FOR RELOCATION OF EXISTING GAS WATER HEATER, | | INCLUDING GAS RISER DIAGRAM INCLUDING ANY OTHER | | EXISTING APPLIANCES AND BTUH VALUES, PIPE SIZING | | CRITERIA, WHERE EXISTING IS LOCATED, EXISTING PIPING ON | | PLAN, HOW IT IS TO BE RE ROUTED, PIPING MATERIALS AND | | VALVING, CONFIRM THE EXISTING WATER HEATER IS FOR | | OUTDOOR INSTALLATION AND SUBMIT WATER HEATER | | INSTALLATION MANUAL. THIS IS A SECOND REQUEST. | | 2. FBC 107.2.1 NOTE ON DRAWING SAYS SEE ATTACHED SPEC | | FOR EXISTING WATER HEATER AND I FIND NONE UPLOADED TO | | THE PROJECT FOR REVIEW. | | 3. FBC FUEL GAS SECTION 404. PLEASE NOT THAT PIPING IN | | CONCEALED LOCATIONS SHALL NOT HAVE UNIONS, TUBING | | FITTINGS, RIGHT AND LEFT COUPLINGS, BUSHINGS, | | COMPRESSION COUPLINGS AND SWING JOINTS MADE BY | | COMBINATIONS OF FITTINGS UNLESS THE FITTINGS ARE LISTED | | FOR USE IN CONCEALED LOCATIONS. | | | | REVIEWED REMOTELY BY JAMES BAKER, PE | | PX3997, PE77268 | | 561-805-6724 | | [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-03-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-03-24 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-03-24 |
Time |
13:55 |
Sent To |
|
|
Notes |
2020-03-24 13:57:03 | 1. FBC 107.2.1 PROVIDE COMPLETE INSTALLATION PLAN | | DRAWING FOR RELOCATION OF EXISTING GAS WATER HEATER, | | INCLUDING GAS RISER DIAGRAM INCLUDING ANY OTHER | | EXISTING APPLIANCES AND BTUH VALUES, PIPE SIZING | | CRITERIA, WHERE EXISTING IS LOCATED, EXISTING PIPING ON | | PLAN, HOW IT IS TO BE RE ROUTED, PIPING MATERIALS AND | | VALVING, CONFIRM THE EXISTING WATER HEATER IS FOR | | OUTDOOR INSTALLATION AND SUBMIT WATER HEATER | | INSTALLATION MANUAL. THIS IS A SECOND REQUEST. | | 2. FBC 107.2.1 NOTE ON DRAWING SAYS SEE ATTACHED SPEC | | FOR EXISTING WATER HEATER AND I FIND NONE UPLOADED TO | | THE PROJECT FOR REVIEW. | | 3. FBC FUEL GAS SECTION 404. PLEASE NOT THAT PIPING IN | | CONCEALED LOCATIONS SHALL NOT HAVE UNIONS, TUBING | | FITTINGS, RIGHT AND LEFT COUPLINGS, BUSHINGS, | | COMPRESSION COUPLINGS AND SWING JOINTS MADE BY | | COMBINATIONS OF FITTINGS UNLESS THE FITTINGS ARE LISTED | | FOR USE IN CONCEALED LOCATIONS. | | | | REVIEWED REMOTELY BY JAMES BAKER, PE | | PX3997, PE77268 | | 561-805-6724 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-04-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-28 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-16 |
Time |
13:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-04-01 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-04-01 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-03-20 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-02-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-02-22 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-02-10 |
Time |
09:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2020-05-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-02-22 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-02-14 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2020-02-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-02-22 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-02-14 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
N |
Date |
2020-05-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-04 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-04 |
Time |
10:50 |
Sent To |
|
|
Notes |
2020-05-04 11:03:41 | SEPERATE GAS PERMIT REQUIRED. CT |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2020-04-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-28 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-27 |
Time |
15:05 |
Sent To |
|
|
Notes |
2020-04-28 09:40:36 | PLAN REVIEW - PLUMBING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 3RD REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY HAVE ADDITIONAL COMMENTS IN PARENTHESES. | | ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. FBC 107.2.1 PROVIDE COMPLETE INSTALLATION PLAN | | DRAWING FOR PLUMBING WATER PIPING, PIPING MATERIALS, | | VALVES, INSULATION REQUIREMENTS, AND ANY OTHER | | INFORMATION THAT IS CODE REQUIRED. NOT ADDRESSED | | | | 2. FBC 107.2.1 PROVIDE DETAILS OF WATER HEATER | | INSTALLATION. CORRECTED | | | | | | 1ST REVIEW BY: | | REVIEWED REMOTELY BY JAMES BAKER, PE | | PX3997, PE77268 | | 561-805-6724 | | [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-03-24 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2020-03-24 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-03-24 |
Time |
11:31 |
Sent To |
|
|
Notes |
2020-03-24 13:54:53 | 1. FBC 107.2.1 PROVIDE COMPLETE INSTALLATION PLAN | | DRAWING FOR PLUMBING WATER PIPING, PIPING MATERIALS, | | VALVES, INSULATION REQUIREMENTS, AND ANY OTHER | | INFORMATION THAT IS CODE REQUIRED. | | 2. FBC 107.2.1 PROVIDE DETAILS OF WATER HEATER | | INSTALLATION. | | | | REVIEWED REMOTELY BY JAMES BAKER, PE | | PX3997, PE77268 | | 561-805-6724 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-02-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-02-22 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-02-22 |
Time |
07:31 |
Sent To |
|
|
Notes |
2020-02-22 08:29:34 | PLAN REVIEW - PLUMBING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PLUMBING PERMIT REQUIRED. RE-LOCATION OF WATER | | HEATER. | | PERMITS | | 105.1 REQUIRED. | | | | 2. PROVIDE PLUMBING PLAN FOR RE-LOCATION OF WATER | | HEATER. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-30 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-27 |
Time |
16:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-02-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-02-22 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-02-14 |
Time |
08:33 |
Sent To |
|
|
Notes |
2020-02-22 08:31:22 | PLAN REVIEW - ROOFING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | PERMITS | | 105.1 REQUIRED. | | | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | SYSTEM COMPONENTS. | | PROVIDE PRODUCT APPROVALS | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2020-05-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-05-03 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-05-03 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2020-04-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-28 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-27 |
Time |
15:05 |
Sent To |
|
|
Notes |
2020-04-28 09:49:50 | PLAN REVIEW - DIGITAL SIGNATURE | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 4TH REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY HAVE ADDITIONAL COMMENTS IN PARENTHESES. | | ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 2ND REVIEW | | | | ENGINEER'S SIGNATURE IS SELF CERTIFIED WHICH IS NOT | | ALLOWED BY FLORIDA BOARD OF PROFESSIONAL ENGINEERS. | | HAVE ENGINEER SEND EVIDENCE THAT HE IS IN THE PROCESS | | OF OBTAINING A COMPLIANT DIGITAL SIGNATURE. | | WHICH IS NOT ALLOWED BY FLORIDA BOARD OF PROFESSIONAL | | ENGINEERS. HAVE ENGINEER SEND EVIDENCE THAT HE IS IN | | THE PROCESS OF OBTAINING A COMPLIANT DIGITAL SIGNATURE. | | | | (DIGITAL SIGNATURE IS NOT ISSUED IN A MANNER WHICH IS | | ACCEPTABLE TO EITHER FBPE OR FLORIDA BOARD OF | | PROFESSIONAL ENGINEERS. THIS TYPE OF SELF CERTIFICATION | | IS NOT INTENDED TO BE USED FOR PROFESSIONAL PURPOSES. | | THIRD PARTY CERTIFICATION IS REQUIRED). | | | | NEW COMMENTS - 3RD REVIEW | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | NEW COMMENTS - 4TH REVIEW | | | | OPTION: | | | | DESIGNER OF RECORD MAY ELECT TO PROVIDE HARD COPY OF | | PLANS WITH WET SEALS AND SIGNATURES. A DROP BOX HAS | | BEEN INSTALLED OUTSIDE CITY HALL FOR THIS PURPOSE. | | PLEASE CONTACT DEVELOPMENT SERVICES IF THIS OPTION IS | | TO BE USED. CITY STAFF WILL REVIEW SIGNATURES AND SEALS | | AND IF APPROVED YOU WILL BE NOTIFIED TO DOWNLOAD AND | | PRINT YOUR PERMIT. | | | | NOTE: ALL OTHER REVIEWS MUST BE APPROVED. | | | | | | | 2020-04-24 13:30:08 | NOT ABLE TO VERIFY SIGNATURE JLEAHY |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2020-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-30 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-30 |
Time |
08:35 |
Sent To |
|
|
Notes |
2020-03-30 11:08:42 | PLAN REVIEW - DIGITAL SIGNATURE | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 3RD REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY HAVE ADDITIONAL COMMENTS IN PARENTHESES. | | ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 2ND REVIEW | | | | ENGINEER'S SIGNATURE IS SELF CERTIFIED WHICH IS NOT | | ALLOWED BY FLORIDA BOARD OF PROFESSIONAL ENGINEERS. | | HAVE ENGINEER SEND EVIDENCE THAT HE IS IN THE PROCESS | | OF OBTAINING A COMPLIANT DIGITAL SIGNATURE. | | WHICH IS NOT ALLOWED BY FLORIDA BOARD OF PROFESSIONAL | | ENGINEERS. HAVE ENGINEER SEND EVIDENCE THAT HE IS IN | | THE PROCESS OF OBTAINING A COMPLIANT DIGITAL SIGNATURE. | | | | (DIGITAL SIGNATURE IS NOT ISSUED IN A MANNER WHICH IS | | ACCEPTABLE TO EITHER FBPE OR FLORIDA BOARD OF | | PROFESSIONAL ENGINEERS. THIS TYPE OF SELF CERTIFICATION | | IS NOT INTENDED TO BE USED FOR PROFESSIONAL PURPOSES. | | THIRD PARTY CERTIFICATION IS REQUIRED). | | | | NEW COMMENTS - 3RD REVIEW | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-03-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-03-24 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-03-24 |
Time |
13:57 |
Sent To |
|
|
Notes |
2020-03-24 13:58:58 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | ENGINEER'S SIGNATURE IS SELF CERTIFIED WHICH IS NOT | | ALLOWED BY FLORIDA BOARD OF PROFESSIONAL ENGINEERS. | | HAVE ENGINEER SEND EVIDENCE THAT HE IS IN THE PROCESS | | OF OBTAINING A COMPLIANT DIGITAL SIGNATURE. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-02-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-02-18 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-02-14 |
Time |
08:33 |
Sent To |
|
|
Notes |
2020-02-18 11:37:49 | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2020-04-20 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-04-20 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-04-20 |
Time |
14:28 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-04-01 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-04-01 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-04-01 |
Time |
09:40 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-02-21 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-02-21 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-02-21 |
Time |
09:32 |
Sent To |
I |
|
Notes |
2020-02-21 09:39:51 | 02/21/20 FAILED. | | | | PLEASE PROVIDE A SURVEY WITH THE PROPOSED ADDITIONS AND | | ITS SETBACKS TO THE PROPERTY LINES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | DEVELOPMENT SERVICES DEPARTMENT | | E-MAIL: [email protected] | | TEL: (561) 822-1442 |
|
|