Notes
2020-02-14 13:38:17RECEIVED E-MAIL FROM BRITNI FORM STORM ROOFING.
 TU PLUS FL5259-R29 SELECTED ASSEMBLY #5 ON PAGE 6 OF
 16.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-02-13 Cont ID  
Sent By jgomez Date 2020-02-14 Time 15:51 Rev Time 0.00
Received By jgomez Date 2020-02-13 Time 14:28 Sent To  
Notes
2020-02-13 16:22:0702/13/2020 E-MAIL FROM BRITNI (STORM ROOFING)I:
  
 1. WE WILL BE USING A MEDIUM PATTY AS PER OUR PHONE
 CONVERSATION.
 2. WE ARE SWITCHING THE UNDERLAYMENT FROM TU PLUS TO
 THE POLYGLASS IRXE WHICH WILL GO DIRECT TO DECK,
 FOLLOWED BY 30# FELT. I HAVE ATTACHED THE UPDATED
 PRODUCT APPROVAL FOR THIS.
 3. WE ARE CHANGING THE PRODUCT APPROVAL TO THE
 CERTAINTEED MODIFIED FOR TILE UNDERLAYMENT, PLEASE SEE
 ATTACHED.
 THANKS!!!
 BRITNI
 STORM ROOFING, INC.
 1340 53RD STREET, SUITE 8
 WEST PALM BEACH, FL 33407
 561-689-0268
 561-845-9182 FAX
 [email protected]
  
 RESPONSE TO E-MAIL.
  
 1- UNDERLAYMENT POLYGLASS IR-XE PROPOSED MAY NOT BE
 APPROPRIATE FOR THE PROPOSED INSTALLATION. ACCORDING TO
 TABLE 1 ON PAGE 4 OF 16 OF FLORIDA PRODUCT APPROVAL
 FL5259-R29 THIS UNDERLAYMENT CAN NO BE USED FOR ROOF
 TILE (NAIL-ON TILE OR FOAM-ON TILE).
  
 NOTE:
 IF THE PURPOSE IS TO HAVE AN ADDITIONAL BASE LAYER THAT
 IS DIRECTLY ADHERED TO THE ROOF DECK, THEN YOU MAY WANT
 TO SEE IF SYSTEM #5 ON PAGE 6 OF 16 OF POLYGLASS TU
 PLUS OF FLORIDA PRODUCT APPROVAL FL5259-R29 MAY WORK
 FOR YOU. THIS IS AN APPROVED SYSTEM WITH HIGH DESIGN
 PRESSURES THAT WORKS FOR THIS BUILDING LOCATION. AND,
 MAY HAVE ALL THE PACKAGE YOUR CLIENT NEEDS.
 OTHERWISE, A COMPLETE PROPOSED ASSEMBLY DOCUMENTATION
 SUPPORTING HOW THE PROPOSED ASSEMBLY WILL WORK TO
 COMPLY WITH SEC. 706.1 FBC-EXISTING BUILDING CAN BE
 SUBMITTED FOR BUILDING OFFICIAL APPROVAL. THIS WILL BE
 SUBMITTED AS AN ALTERNATIVE MATERIAL AND METHODS. SEC.
 104.11 CITY AMENDMENTS.
  
 2- I APOLOGIZE, I FORGOT TO ASK YOU THE FIRST TIME.
 SINCE THERE ARE SEVERAL BUILDINGS IN THIS PROPERTY, CAN
 YOU PLEASE PROVIDE AN AERIAL VIEW FROM PAPA SHOWING
 WHICH BUILDING AND ROOF AREA IS THE WORK TAKING PLACE.
 SEC. 107.2.1 CITY AMENDMENTS.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-02-10 Cont ID  
Sent By jgomez Date 2020-02-10 Time 15:57 Rev Time 0.00
Received By jgomez Date 2020-02-10 Time 15:55 Sent To  
Notes
2020-02-10 16:12:41RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOF TILE FLORIDA PRODUCT APPROVAL FL17152-R3 AND
 ROOF TILE ADHESIVE FLORIDA PRODUCT APPROVAL FL6332-R8
 SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE AS REQUIRED
 BY CITY POLICY FOR ALL ROOFING PERMITS TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC R301.2.1
 FBC-RESIDENTIAL.
  
 2- ROOFING UNDERLAYMENT TU PLUS-MAX FLORIDA PRODUCT
 APPROVALS FL5259-R29 SUBMITTED:
 CLEARLY MARK WHICH MAXIMUM DESIGN PRESSURES ASSEMBLY
 FROM SEC. 5.6.1 OF PRODUCT APPROVAL IS GOING TO BE
 USED. OR IF USING THE FRSA/TRI APRIL 2012 (04-12)
 REVISED EDITION, THEN PROVIDE COMPLETE INFORMATION
 SHOWING THE DETERMINATION OF DESIGN WIND LOADS AND
 UNDERLAYMENT FASTENING AS REQUIRED BY SEC. 5.6.1 OF
 PRODUCT APPROVAL SUBMITTED.
  
 3- IT IS NOT CLEAR WHY SUBMITTING FLAT ROOF FLORIDA
 PRODUCT APPROVAL FL16709-R6. COVER PAGE STATES "PG 3 OF
 4 MODIFIED FOR THE UNDERLAYMENT ONLY". IS THIS THE
 UNDERLAYMENT FOR THE TILE ROOF?. IF SO, THIS IS A FLAT
 ROOF ASSEMBLY NOT AN UNDERLAYMENT FOR ROOF TILE. THE
 UNDERLAYMENT FOR THE ROOF TILE IS THE TU PLUS PRODUCT
 APPROVAL SUBMITTED. SEC. 107.2.1 CITY AMENDMENTS.
 ***NOTE:
 02/10/2020 TALKED TO BRITNI FROM STORM ROOFING. SHE
 SAID THEY ARE INSTALLING THE MODIFIED MEMBRANE
 (FLINTLASTIC GMS) ON TOP OF THE TU PLUS. THIS WILL BE
 THE UNDERLAYMENT FOR THE ROOF TILE. I TOLD BRITNI THE
 PROPOSED INSTALLATION IS NOT AN APPROVED SYSTEM. TOLD
 HER THE PROPOSED INSTALLATION COULD BE SUBMITTED AS AN
 ALTERNATIVE MATERIALS AND METHODS SEC. 104.11 CITY
 AMENDMENTS. DISCUSSED THIS ISSUE WITH ROBERT BROWN
 (BUILDING OFFICIAL). HE AGREED, PROPOSED INSTALLATION
 NEEDS TO BE SUBMITTED AS ALTERNATIVE MATERIALS AND
 METHODS. THEREFORE, NEED TO PROVIDE COMPLETE DATA
 SHOWING THAT THE PROPOSED INSTALLATION WILL WORK.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-10 Cont ID  
Sent By jgomez Date 2020-02-10 Time 09:35 Rev Time 0.00
Received By jgomez Date 2020-02-10 Time 08:05 Sent To  
Notes
2020-02-10 09:36:27RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOF TILE FLORIDA PRODUCT APPROVAL FL17152-R3 AND
 ROOF TILE ADHESIVE FLORIDA PRODUCT APPROVAL FL6332-R8
 SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE AS REQUIRED
 BY CITY POLICY FOR ALL ROOFING PERMITS TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC R301.2.1
 FBC-RESIDENTIAL.
  
 2- ROOFING UNDERLAYMENT TU PLUS-MAX FLORIDA PRODUCT
 APPROVALS FL5259-R29 SUBMITTED:
 CLEARLY MARK WHICH MAXIMUM DESIGN PRESSURES ASSEMBLY
 FROM SEC. 5.6.1 OF PRODUCT APPROVAL IS GOING TO BE
 USED. OR IF USING THE FRSA/TRI APRIL 2012 (04-12)
 REVISED EDITION, THEN PROVIDE COMPLETE INFORMATION
 SHOWING THE DETERMINATION OF DESIGN WIND LOADS AND
 UNDERLAYMENT FASTENING AS REQUIRED BY SEC. 5.6.1 OF
 PRODUCT APPROVAL SUBMITTED.
  
 3- IT IS NOT CLEAR WHY SUBMITTING FLAT ROOF FLORIDA
 PRODUCT APPROVAL FL16709-R6. COVER PAGE STATES "PG 3 OF
 4 MODIFIED FOR THE UNDERLAYMENT ONLY". IS THIS THE
 UNDERLAYMENT FOR THE TILE ROOF?. IF SO, THIS IS A FLAT
 ROOF ASSEMBLY NOT AN UNDERLAYMENT FOR ROOF TILE. THE
 UNDERLAYMENT FOR THE ROOF TILE IS THE TU PLUS PRODUCT
 APPROVAL SUBMITTED. SEC. 107.2.1 CITY AMENDMNTS.
  
 ON THE OTHER HAND, IF THERE IS A FLAT ROOF IN THIS ROOF
 , THEN CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO
 BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-02-14 Cont ID  
Sent By jgomez Date 2020-02-14 Time 14:07 Rev Time 0.00
Received By jgomez Date 2020-02-14 Time 13:35 Sent To I
Notes
2020-02-14 13:37:58RECEIVED E-MAIL FROM BRITNI FORM STORM ROOFING.
 TU PLUS FL5259-R29 SELECTED ASSEMBLY #5 ON PAGE 6 OF
 16.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status F Date 2020-02-13 Cont ID  
Sent By jgomez Date 2020-02-13 Time 16:25 Rev Time 0.00
Received By jgomez Date 2020-02-13 Time 14:27 Sent To  
Notes
2020-02-13 14:28:12RECEIVED E-MAIL FROM BRITNI.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-10 Cont ID  
Sent By jgomez Date 2020-02-10 Time 16:12 Rev Time 0.00
Received By jgomez Date 2020-02-10 Time 15:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-10 Cont ID  
Sent By jgomez Date 2020-02-10 Time 09:36 Rev Time 0.00
Received By jgomez Date 2020-02-06 Time 14:46 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved