Plan Review Details - Permit 20020093
Plan Review Stops For Permit 20020093
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-02-12 Cont ID  
Sent By jgomez Date 2020-02-12 Time 17:30 Rev Time 0.00
Received By jgomez Date 2020-02-12 Time 16:44 Sent To  
Notes
2020-02-12 16:54:19RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOF TILE FL 7804-R10 SUBMITTED. CLEARLY SPECIFY
 TILE FASTENING METHOD AS REQUIRED BY CITY POLICY FOR
 ALL ROOFFING PERMITS TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R3012.1 FBC-RESIDENTIAL. IF
 SPECIFYING SCREWS, THEN SPECIFY THE NUMBER AND SIZE OF
 SCREWS TO BE USED FOR ALL ROOF ZONES. IF USING
 ADHESIVE, THEN PROVIDE PRODUCT APPROVAL AND CLEARLY
 MARK PADDY SIZE.
 NOTE: KEEP IN MIND THAT THIS BUILDING IS LOCATED IN
 WIND EXPOSURE D. PROPOSED FASTENING NEEDS TO MEET THE
 REQUIRED ROOF TILE RESISTANCE VALUE FOR ALL ROOF ZONES
 BASED ON THE BUILDING EXPOSURE AND BUILDING HEIGHT.
 PROVIDE INFORMATION SHOWING THE ROOF TILE RESISTANCE
 VALUE ON ALL ROOF ZONES.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-06 Cont ID  
Sent By jgomez Date 2020-02-06 Time 15:30 Rev Time 0.00
Received By jgomez Date 2020-02-06 Time 15:09 Sent To I
Notes
2020-02-06 15:30:58RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOF TILE FL 7804-R10 SUBMITTED. CLEARLY SPECIFY
 TILE FASTENING METHOD AS REQUIRED BY CITY POLICY FOR
 ALL ROOFFING PERMITS TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R3012.1 FBC-RESIDENTIAL. IF
 SPECIFYING SCREWS, THEN SPECIFY THE NUMBER AND SIZE OF
 SCREWS TO BE USED FOR ALL ROOF ZONES. IF USING
 ADHESIVE, THEN PROVIDE PRODUCT APPROVAL AND CLEARLY
 MARK PADDY SIZE.
 NOTE: KEEP IN MIND THAT THIS BUILDING IS LOCATED IN
 WIND EXPOSURE D. PROPOSED FASTENING NEEDS TO MEET THE
 REQUIRED ROOF TILE RESISTANCE VALUE FOR ALL ROOF ZONES
 BASED ON THE BUILDING EXPOSURE AND BUILDING HEIGHT.
 PROVIDE INFORMATION SHOWING THE ROOF TILE RESISTANCE
 VALUE ON ALL ROOF ZONES.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-12 Cont ID  
Sent By jgomez Date 2020-02-12 Time 17:30 Rev Time 0.00
Received By jgomez Date 2020-02-11 Time 13:44 Sent To I
Notes
2020-02-12 13:45:06RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-06 Cont ID  
Sent By jgomez Date 2020-02-06 Time 16:29 Rev Time 0.00
Received By jgomez Date 2020-02-04 Time 13:47 Sent To I
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-09-15 Cont ID  
Sent By pvalenti Date 2021-09-15 Time 06:32 Rev Time 0.00
Received By pvalenti Date 2021-09-15 Time 06:31 Sent To  
Notes
2021-09-15 06:33:17 
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 SIGNATURE REVIEW APPRIOVED BY SIGNED/SEALED PAPER
 PLANS. PLANS ROUTED TO STORAGE.


Account Summary | Usage Policy | Privacy Policy