Plan Review Stops For Permit 20020083 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
N |
Date |
2020-02-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-11 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-02-11 |
Time |
10:17 |
Sent To |
|
|
Notes |
2020-02-11 10:18:20 | BUILT ON 2006. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-04-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-04-01 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-04-01 |
Time |
10:16 |
Sent To |
|
|
Notes |
2020-04-01 11:21:50 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1)SEPARATE SPRINKLER PERMIT WILL BE REQUIRED FOR ANY | | MODIFICATIONS. | | 2)FLOORING SOUND INSULATION MATERIAL FOR NEW TILE: | | A) PROVIDE 2 COPIES OF THE FLAME SPREAD INDEX AND SMOKE | | DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84 | | OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 6TH EDITION | | (2017). | | B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS | | (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS | | REQUIRED BY SEC. 1207.2 OF FBC 6TH EDITION (2017). | | C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS | | (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS | | REQUIRED BY SEC. 1207.3 OF FBC 6TH EDITION (2017). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-03-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-10 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-10 |
Time |
11:37 |
Sent To |
|
|
Notes |
2020-03-10 12:53:33 | SECOND BUILDING REVIEW CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | ISSUANCE. | | | | | | | | 1- OK | | 2- OK | | 3- SEPARATE SPRINKLER PERMIT WILL BE REQUIRED FOR ANY | | MODIFICATIONS. | | | | ORIGINAL COMMENT. | | 4-FLOORING SOUND INSULATION MATERIAL FOR NEW TILE: | | A) PROVIDE 2 COPIES OF THE FLAME SPREAD INDEX AND SMOKE | | DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84 | | OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 6TH EDITION | | (2017). | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS | | (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS | | REQUIRED BY SEC. 1207.2 OF FBC 6TH EDITION (2017). | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS | | (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS | | REQUIRED BY SEC. 1207.3 OF FBC 6TH EDITION (2017). | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING | | CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE | | TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT | | ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED | | ACOUSTICAL CEILINGS IN THESE BUILDINGS. | | | | 5- OK | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-02-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-11 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-02-11 |
Time |
08:43 |
Sent To |
|
|
Notes |
2020-02-11 13:50:55 | BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- ADDRESS OF PROJECT SHOWN ON ALL PLANS IS INCORRECT. | | THE CORRECT ADDRESS IS 610 CLEMATIS ST. NOT 601. REVISE | | AS REQUIRED. NOTE: COVER SHEET HAS 4 PLACES LISTING THE | | INCORRECT ADDRESS. PLEASE MAKE SURE ALL THE INFORMATION | | IS CORRECTED. SEC. 107.2.1 CITY AMENDMENTS. | | | | 2- ONLY ONE SET OF PLANS WAS SIGNED AND SEALED BY THE | | ARCHITECT OF RECORD. THE OTHER COPY WAS NOT SIGNED AND | | SEALED. BOTH COPIES NEED TO BE SIGNED AND SEALED | | (ORIGINAL SEAL AND SIGNATURE) SEC. 107.1 CITY | | AMENDMENTS. CHAPTER 481 FLORIDA STATUTES. | | | | 3- INFORMATION ABOUT SPRINKLER HEADS IS NOT CLEAR. SEC. | | 107.2.1 CITY AMENDMENTS. KEY NOTE #8 ON THE DEMOLITION | | PLAN ON SHEET A2.1 CALLS FOR REMOVAL AND CAPPING OF | | EXISTING SIDEWALL SPRINKLER HEAD AND SUPPLY LINE. ON | | THE OTHER HAND, KEY NOTE #11ON THE NEW FLOOR PLAN ON | | SHEET A2.2 CALLS TO VERIFY IF EXISTING SPRINKLER HEAD | | WILL COVER THE NEW EXPOSED AREA. CLEARLY SPECIFY | | PROPOSED ALTERATION TO THE SPRINKLER SYSTEM. NOTE: | | SEPARATE PERMIT WILL BE REQUIRED. | | | | 4-FLOORING SOUND INSULATION MATERIAL FOR NEW TILE: | | | | A) PROVIDE 2 COPIES OF THE FLAME SPREAD INDEX AND SMOKE | | DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84 | | OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 6TH EDITION | | (2017). | | | | B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS | | (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS | | REQUIRED BY SEC. 1207.2 OF FBC 6TH EDITION (2017). | | | | C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS | | (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS | | REQUIRED BY SEC. 1207.3 OF FBC 6TH EDITION (2017). | | | | NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING | | CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE | | TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT | | ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED | | ACOUSTICAL CEILINGS IN THESE BUILDINGS. | | | | 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS LOW. | | VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S | | OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS | | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. UPDATE | | VALUATION TO INCLUDE ALL COSTS OR PROVIDE COPY OF | | SIGNED CONTRACTS INCLUDING DESIGN PROFESSIONAL FEES. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-03-31 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-03-31 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-03-31 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-03-10 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-03-10 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-03-10 |
Time |
07:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-02-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-02-07 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-02-07 |
Time |
13:45 |
Sent To |
|
|
Notes |
2020-02-07 13:49:15 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED (AND | | SEALED WHERE APPLICABLE) BY THE PERSON RESPONSIBLE FOR | | THE DESIGN. THIS RESPONSIBLE PERSON SHOULD BE EITHER A | | DESIGN PROFESSIONAL OR THE ELECTRICAL CONTRACTOR | | QUALIFIER. WPB FBC 107.2.1, 107.3.5; FS 471, 481 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-03-04 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-03-04 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-03-04 |
Time |
10:45 |
Sent To |
|
|
Notes |
2020-03-04 10:51:17 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING AREA | | MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE FIRE | | SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY A | | CERTIFIED FIRE SPRINKLER CONTRACTOR. | | | | 2) ANY AND ALL WORK ON THE FIRE SPRINKLER SYSTEMS SHALL | | BE DONE UNDER SEPARATE SHOP DRAWINGS AND BY A CERTIFIED | | FIRE SPRINKLER CONTRACTOR. | | | | 3) THE FIRE SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT | | THE CONSTRUCTION PERIOD. | | | | PETER LEDUC | | FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-02-07 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-02-07 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-02-07 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-04-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-04-01 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-30 |
Time |
13:06 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-03-16 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-02-26 |
Time |
13:38 |
Sent To |
|
|
Notes |
2020-03-12 11:47:47 | MECHANICAL REVIEW REQUIRED PER HAROLD MOSER; ADDED STOP | 2020-02-27 13:38:33 | B11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-02-12 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-02-12 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-02-04 |
Time |
13:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-03-31 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-31 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-31 |
Time |
08:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2020-03-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-16 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-16 |
Time |
10:55 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2020-03-31 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-31 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-31 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-03-12 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2020-03-12 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2020-03-12 |
Time |
11:30 |
Sent To |
|
|
Notes |
2020-03-12 11:45:42 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | | | 2ND REVIEW | | PLUMBING COMMENTS: DENIED | | 1. PER WPB FBC 107.2.1, SHOW LOCATION OF EXISTING STACK | | THAT WASHER DRYER IS TO BE CONNECTED TO. PROVIDE A | | SANITARY RISER DIAGRAM SHOWING HOW KEYNOTE #7 ON PLAN | | PAGE A2.2 WILL BE ACCOMPLISHED. IF THIS IS A SINGLE | | PIPE STACK (WASTE STACK VENT AS DESCRIBED IN FBC PL | | 913), IT SHALL NOT BE OFFSET. PLEASE REFER TO THE | | PROVISIONS OF FBC PL 905, 909 AND 913 FOR GUIDANCE. | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 | | | | 20020083 610 CLEMATIS ST | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-02-12 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-02-12 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-02-12 |
Time |
15:21 |
Sent To |
|
|
Notes |
2020-02-12 15:32:56 | 02/12/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. ON THE SECOND PLAN THE SIGNATURE AND SEAL ARE | | MISSING (OR SEAL, OR TITLE BLOCK, OR ALL THREE) WHICH | | ARE NOT IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE | | 61G15-23.001, FLORIDA STATUTE 471 PER THE WPB | | AMENDMENTS TO THE FBC SEC. 107.1 GENERAL. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|