Plan Review Details - Permit 20020040
Plan Review Stops For Permit 20020040
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-03-04 Cont ID  
Sent By rmcdouga Date 2020-03-04 Time 14:09 Rev Time 0.00
Received By rmcdouga Date 2020-03-04 Time 14:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-06 Cont ID  
Sent By rmcdouga Date 2020-02-06 Time 14:50 Rev Time 0.00
Received By rmcdouga Date 2020-02-06 Time 06:59 Sent To E
Notes
2020-02-06 14:50:44 
 PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) BY THE DEFINITION IN FS 514.011, THIS IS A PUBLIC
 SWIMMING POOL BECAUSE IT SERVES FIVE OR MORE
 APARTMENTS. SHOW HOW THIS POOL WILL MEET THE ACCESSIBLE
 MEANS OF ENTRY REQUIREMENTS OF THE 2017 FBC
 ACCESSIBILITY, SECTION 242.2. IF THIS SWIMMING POOL IS
 INTENDED SOLELY FOR THE USE OF RESIDENTS AND THEIR
 GUESTS AND THE DEVELOPMENT RECEIVES NO GOVERNMENTAL
 FINANCIAL ASSISTANCE OR SPONSORSHIP, THEN IT IS NOT
 SUBJECT TO THE ACCESSIBILITY CODE REQUIREMENTS FOR POOL
 LIFTS AND SLOPED ENTRIES. IF YOU WISH TO USE THE
 EXEMPTION FROM ACCESSIBLE ENTRANCE TO THE POOL, PROVIDE
 A STATEMENT ON THE PLANS THAT THE POOL IS INTENDED
 SOLELY FOR THE USE OF RESIDENTS AND THEIR GUESTS AND
 THE DEVELOPMENT RECEIVES NO GOVERNMENTAL FINANCIAL
 ASSISTANCE OR SPONSORSHIP.
  
 2) SUBMIT PROOF THAT AN APPLICATION FOR AN OPERATING
 PERMIT HAS BEEN SUBMITTED TO THE PALM BEACH COUNTY
 HEALTH DEPARTMENT AS REQUIRED BY FLORIDA STATUTES.
 FS 514.03 APPROVAL NECESSARY TO CONSTRUCT, DEVELOP, OR
 MODIFY PUBLIC SWIMMING POOLS OR PUBLIC BATHING PLACES.
 (1) A PERSON OR PUBLIC BODY DESIRING TO CONSTRUCT,
 DEVELOP, OR MODIFY A PUBLIC SWIMMING POOL MUST SUBMIT
 AN APPLICATION, CONTAINING THE INFORMATION REQUIRED
 UNDER S. 514.031(1)(A)1.-6. TO THE DEPARTMENT FOR AN
 OPERATING PERMIT BEFORE FILING AN APPLICATION FOR A
 BUILDING PERMIT UNDER S. 553.79. A COPY OF THE FINAL
 INSPECTION REQUIRED UNDER S. 514.031(1)(A)5. SHALL BE
 SUBMITTED TO THE DEPARTMENT UPON RECEIPT BY THE
 APPLICANT. THE APPLICATION SHALL BE DEEMED INCOMPLETE
 PURSUANT TO S. 120.60 UNTIL SUCH COPY IS SUBMITTED TO
 THE DEPARTMENT.
 (2) LOCAL GOVERNMENTS OR LOCAL ENFORCEMENT DISTRICTS
 MAY DETERMINE COMPLIANCE WITH THE GENERAL CONSTRUCTION
 STANDARDS OF THE FLORIDA BUILDING CODE, PURSUANT TO S.
 553.80. LOCAL GOVERNMENTS OR LOCAL ENFORCEMENT
 DISTRICTS MAY CONDUCT PLAN REVIEWS AND INSPECTIONS OF
 PUBLIC SWIMMING POOLS AND PUBLIC BATHING PLACES FOR
 THIS PURPOSE.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-03-06 Cont ID  
Sent By jleahy Date 2020-03-06 Time 08:11 Rev Time 0.00
Received By jleahy Date 2020-03-06 Time 08:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-02-07 Cont ID  
Sent By jleahy Date 2020-02-07 Time 11:33 Rev Time 0.00
Received By jleahy Date 2020-02-07 Time 11:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-12 Cont ID  
Sent By tklarge Date 2020-03-12 Time 08:43 Rev Time 0.00
Received By tklarge Date 2020-03-12 Time 08:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-06 Cont ID  
Sent By jleahy Date 2020-03-06 Time 08:11 Rev Time 0.00
Received By jleahy Date 2020-02-26 Time 13:24 Sent To  
Notes
2020-03-02 17:54:49ROUTED TO TLARGE INBOX
2020-02-27 13:24:54RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-10 Cont ID  
Sent By tklarge Date 2020-02-10 Time 10:50 Rev Time 0.00
Received By tklarge Date 2020-02-03 Time 13:00 Sent To  
Notes
2020-02-05 16:08:12ROUTED TO POOL BOX
2020-02-04 13:00:47ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-03-12 Cont ID  
Sent By tklarge Date 2020-03-12 Time 08:43 Rev Time 0.00
Received By tklarge Date 2020-03-12 Time 08:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-03-04 Cont ID  
Sent By tklarge Date 2020-03-04 Time 09:22 Rev Time 0.00
Received By tklarge Date 2020-03-04 Time 05:43 Sent To  
Notes
2020-03-04 09:15:431) SHT. 3 OF 7 SHOWS THE MAIN DRAIN COVER AS 12 INCHES
 BY 12 INCHES BUT SHT. 4 SHOWS THE MAIN DRAIN COVER AS
 18 INCHES BY 18 INCHES . THE MAIN DRAIN DETAIL ON SHT.
 5 OF 7 SHOWS A 12 INCHES BY 12 INCHES GRATE. CLARIFY.
 2) SUBMIT A PUMP CURVE THAT SHOWS THE DESIGN TDH. THE
 PUMP CURVE ON THE PLAN ONLY GOES TO 30 FT. TDH AND THE
 DESIGN IS BASED ON 60 FT. TDH.
 3) A SEPARATE PERMIT WILL BE REQUIRED FOR THE POOL
 HEATER. WPB AMEND. TO FBC SEC. 105.1.
 4) THE PLANS SHOW THE OVERFLOW DISCHARGE AND WASTE TO
 DISCHARGE TO THE CITY STORM SEWER. THIS IS PROHIBITED
 PER CODE OF CITY ORDINANCES ARTICLE V, SEC. 90-203 (A).
 PLEASE CONTACT MANNY GONZALEZ WITH THE CITY'S
 ENGINEERING DEPT. AT 561-494-1085 FOR FURTHER
 DIRECTION.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-02-10 Cont ID  
Sent By tklarge Date 2020-02-10 Time 10:50 Rev Time 0.00
Received By tklarge Date 2020-02-10 Time 09:51 Sent To  
Notes
2020-02-10 09:57:16 
  
 1) BY THE DEFINITION IN FS 514.011, THIS IS A PUBLIC
 SWIMMING POOL BECAUSE IT SERVES FIVE OR MORE
 APARTMENTS. SHOW HOW THIS POOL WILL MEET THE ACCESSIBLE
 MEANS OF ENTRY REQUIREMENTS OF THE 2017 FBC
 ACCESSIBILITY, SECTION 242.2. IF THIS SWIMMING POOL IS
 INTENDED SOLELY FOR THE USE OF RESIDENTS AND THEIR
 GUESTS AND THE DEVELOPMENT RECEIVES NO GOVERNMENTAL
 FINANCIAL ASSISTANCE OR SPONSORSHIP, THEN IT IS NOT
 SUBJECT TO THE ACCESSIBILITY CODE REQUIREMENTS FOR POOL
 LIFTS AND SLOPED ENTRIES. IF YOU WISH TO USE THE
 EXEMPTION FROM ACCESSIBLE ENTRANCE TO THE POOL, PROVIDE
 A STATEMENT ON THE PLANS THAT THE POOL IS INTENDED
 SOLELY FOR THE USE OF RESIDENTS AND THEIR GUESTS AND
 THE DEVELOPMENT RECEIVES NO GOVERNMENTAL FINANCIAL
 ASSISTANCE OR SPONSORSHIP.
  
 2) SUBMIT PROOF THAT AN APPLICATION FOR AN OPERATING
 PERMIT HAS BEEN SUBMITTED TO THE PALM BEACH COUNTY
 HEALTH DEPARTMENT AS REQUIRED BY FLORIDA STATUTES.
 FS 514.03 APPROVAL NECESSARY TO CONSTRUCT, DEVELOP, OR
 MODIFY PUBLIC SWIMMING POOLS OR PUBLIC BATHING PLACES.
 (1) A PERSON OR PUBLIC BODY DESIRING TO CONSTRUCT,
 DEVELOP, OR MODIFY A PUBLIC SWIMMING POOL MUST SUBMIT
 AN APPLICATION, CONTAINING THE INFORMATION REQUIRED
 UNDER S. 514.031(1)(A)1.-6. TO THE DEPARTMENT FOR AN
 OPERATING PERMIT BEFORE FILING AN APPLICATION FOR A
 BUILDING PERMIT UNDER S. 553.79. A COPY OF THE FINAL
 INSPECTION REQUIRED UNDER S. 514.031(1)(A)5. SHALL BE
 SUBMITTED TO THE DEPARTMENT UPON RECEIPT BY THE
 APPLICANT. THE APPLICATION SHALL BE DEEMED INCOMPLETE
 PURSUANT TO S. 120.60 UNTIL SUCH COPY IS SUBMITTED TO
 THE DEPARTMENT.
 (2) LOCAL GOVERNMENTS OR LOCAL ENFORCEMENT DISTRICTS
 MAY DETERMINE COMPLIANCE WITH THE GENERAL CONSTRUCTION
 STANDARDS OF THE FLORIDA BUILDING CODE, PURSUANT TO S.
 553.80. LOCAL GOVERNMENTS OR LOCAL ENFORCEMENT
 DISTRICTS MAY CONDUCT PLAN REVIEWS AND INSPECTIONS OF
 PUBLIC SWIMMING POOLS AND PUBLIC BATHING PLACES FOR
 THIS PURPOSE.
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-03-02 Cont ID  
Sent By rfalcone Date 2020-03-02 Time 14:00 Rev Time 0.00
Received By rfalcone Date 2020-03-02 Time 14:00 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-02-05 Cont ID  
Sent By rfalcone Date 2020-02-05 Time 11:01 Rev Time 0.00
Received By rfalcone Date 2020-02-05 Time 11:01 Sent To  
Notes
***NONE***