2020-02-06 12:58:21 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM |
| (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) |
| 805-6724 |
| [email protected] |
| |
| 1ST REVIEW: FBC 2017 6TH EDITION |
| FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN |
| PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE |
| 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A |
| COMPLETED RESUBMITTAL FORM, VIA EMAIL TO |
| [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT |
| NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE |
| RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: |
| HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B |
| UILDING-PERMIT-FORMS |
| |
| 1. SUBMITTED PRODUCT APPROVAL FL16893-R4 HAS BEEN |
| REVISED TO FL16893-R5. PLEASE PROVIDE TWO SETS. ALL |
| APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY |
| IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS |
| AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT |
| APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER |
| RULE 61G20-3. |
| 2. FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF |
| PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT COLUMN |
| HEADING ?WALL PRESSURE?; PROVIDE THE ACTUAL [PSF] FROM |
| THE SUBMITTED ENGINEERS ASCE 7-10 DESIGN WIND LOADS. |
| PLEASE CORRECT COLUMN HEADING ?SHUTTER INSTALLED? |
| SHUTTERS ARE INSTALLED VERTICALLY AS PER SHEET 2 OF |
| FL16893 R-5. PLEASE CORRECT COLUMN HEADING ?ANCHOR |
| SPACING?; PROVIDE INFORMATION FROM PAGE 13 OF |
| FL16893-R5. EXAMPLE: MAXIMUM A.S.D. DESIGN PRESSURE |
| RATING (P.S.F.) +60.0, -60.0 OR LESS, MAXIMUM SPAN 72?; |
| MOUNT TYPE C; ANCHOR TYPE A1 MAXIMUM ANCHOR SPACING IS |
| 8?. |
| |