Plan Review Details - Permit 20011223
Plan Review Stops For Permit 20011223
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2020-05-20 Cont ID  
Sent By cpuell Date 2020-05-20 Time 08:39 Rev Time 0.00
Received By cpuell Date 2020-05-20 Time 08:39 Sent To  
Notes
2020-05-20 08:40:46ADDRESS CHANGED FOR 401 DATURA TO 445 DATURA,
 ADDITIONAL ADDRESSES FOR SEPARATE ENTRANCES MAY NEED TO
 BE ESTABLISH, BUT AT THIS TIME THE MAIN ADDRESS WILL BE
 445 DATURA

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-04-10 Cont ID  
Sent By cpuell Date 2020-04-10 Time 15:51 Rev Time 0.00
Received By cpuell Date 2020-04-10 Time 15:51 Sent To  
Notes
2020-04-10 15:52:17PLEASE CONTACT [email protected] TO DISCUSS ADDRESS FOR
 THE PROPERTY. PLEASE PROVIDE SITE PLAN IDENTIFYONG THE
 MAIN ENTRANCE.

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2023-01-03 Cont ID  
Sent By scwelter Date 2021-03-25 Time 13:57 Rev Time 0.00
Received By swelter Date 2021-03-25 Time 13:57 Sent To  
Notes
2023-01-03 13:12:49PUBLIC ART REQUIREMENT SATISFIED 1.03.2023
 OPTION 2 CONTRIBUTION
  
2021-03-22 14:41:56PUBLIC ART REQUIREMENT INCOMPLETE
 DEVELOPER AWARE OF REQUIREMENT PER ORDINANCE.
 MISSING PUBLIC ART APPLICATION - 90 DAYS PAST DUE -
 MUST SUBMIT APPLICATION WITH PAYMENT PRIOR TO TCO OR CO
  
 MUST CONTACT SYBILLE WELTER AT [email protected] OR
 561.822.1521
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-11-17 Cont ID  
Sent By rmcphers Date 2020-11-17 Time 07:56 Rev Time 0.00
Received By rmcphers Date 2020-11-17 Time 07:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-10-20 Cont ID  
Sent By rmcphers Date 2020-10-20 Time 07:58 Rev Time 0.00
Received By rmcphers Date 2020-10-15 Time 07:34 Sent To  
Notes
2020-10-20 07:58:29NEW 8 STORY BUILDING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) THE WIND DESIGN DATA HAS BEEN REVISED ON THE
 STRUCTURAL DRAWINGS BUT NOT ON THE PROVIDED STRUCTURAL
 CALCULATIONS - PLEASE REVISE THE STRUCTURAL
 CALCULATIONS TO MATCH THE WIND DESIGN DATA SHOWN ON THE
 STRUCTURAL DRAWINGS.
  
 DEFERRED ITEMS ? TO BE REVIEWED AND MARKED APPROVED BY
 THE BUILDING DESIGNER OF RECORD AND REVIEWED BY THE
 BUILDING DIVISION PLAN REVIEW BEFORE INSTALLATION -
 1) EXTERIOR WINDOW, DOOR AND LOUVER PRODUCT APPROVALS.
 FBC 1609
 2) SHORING AND RESHORING PLANS. FBC 110.8.4.3
 3) GUARD RAILING. FBC 1607.8
 4) ROOFING SYSTEM PRODUCT APPROVALS. FBC 1609.5.2
 5) ROOF TOP EQUIPMENT SCREENING. FBC 1510.6
 6) POOL. FBC 454
 7) ACOUSTICAL TEST REPORTS FOR THE FLOOR/CEILING
 ASSEMBLIES IIC AND STC PER FBC 1207 AND FLAME SPREAD
 INDEX PER FBC 603.1
 8) TRELLIS DETAILS.
 9) METAL CANOPIES.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-07-21 Cont ID  
Sent By dbattles Date 2020-07-20 Time 14:00 Rev Time 0.00
Received By dbattles Date 2020-07-20 Time 13:38 Sent To  
Notes
2020-07-20 14:01:02BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 20011223
 REVIEWED: AUGUST 17, 2020
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[B] = FBC BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 FAIRHOUSING:
  
 1) REQUIREMENT 1 - SHOW AT LEAST ONE ACCESSIBLE ROUTE
 TO BUILDING ENTRANCE. WALKS THAT ARE PART OF ACCESSIBLE
 ROUTES BECOME RAMPS WHEN THEIR SLOPE EXCEEDS 5% (1 IN
 20). HANDRAILS ARE NOT REQUIRED ON WALKS WITH SLOPES
 BETWEEN 0% AND 5%, BUT THEY ARE REQUIRED ON THOSE
 STEEPER THAN 5% AND UP TO 8.33% (1 IN 12)
 - PROVIDE CIVIL PLANS TO VERIFY SLOPES THAT WILL OCCUR
 ON THE ACCESSIBLE PATH. PROVIDE SITE PLAN TO SHOW THE
 ACCESSIBLE PATH FROM PARKING OR OTHER PUBLIC ACCESS
 POINTS SUCH AS BUS STOP OR DROP OFF ZONE.
  
 2) REQUIREMENT 3 - USABLE DOORS. THE DOORS IN COMMON
 SPACES AND THE SIDE ENTERING INTO DWELLING UNITS NEED
 TO HAVE USABLE HARDWARE THAT CAN BE USED WITHOUT TIGHT
 GRASPING OR TWISTING.
 - TYPICALLY THE HARDWARE WOULD BE A LEVER TYPE. THIS
 TYPE OF HARDWARE WOULD NOT BE REQUIRED ONCE INSIDE THE
 UNIT. YOU MAY WANT TO CLARIFY HARDWARE ON THE DOOR
 SCHEDULE.
  
 3) REQUIREMENT 6 - REINFORCED WALLS FOR GRAB BARS
 - BARS ONLY NEED TO BE INSTALLED IN THE PUBLIC OR
 COMMON USE AREAS. ALL OF THE DWELLING UNITS ONLY NEED
 BLOCKING INSTALLED. SHEET A2.3 SHOWS THE BLOCKING AT
 TOILET AND WILL WORK. PLEASE ADD BLOCKING AT SHOWER
 BECAUSE I ONLY SEE CONTROL ZONE AND THAT WILL BE
 COVERED IN REQUIREMENT 7.
  
 4) REQUIREMENT 7 - USABLE KITCHENS.
 - I ONLY SEE ONE KITCHEN IN UNIT S101. PLEASE SHOW
 CLEAR FLOOR SPACE AT COOKTOP,REFRIDGERATOR AND SINK.
 THE CLEAR SPACE SHOULD BE CENTERED ON THE APPLIANCE.THE
 SINK DOESN'T APPEAR THAT IT WOULD WORK, SO THIS MAY
 NEED TO BE RE-WORKED. ALSO, CHECK
  
 5) REQUIREMENT 7 - COMMON LAUNDRY ROOMS.
 - SHOW CLEAR FLOOR SPACE AT WASHER AND DRYER IN LAUNDRY
 ROOM 118 AND LAUNDRY ROOMS ON FLOORS 2-4. THE CLEAR
 SPACE SHOULD BE CENTERED ON THE APPLIANCES.
  
  
 ACCESSIBILITY FBC 2017:
  
 6) 216.6 ENTRANCES. WHERE NOT ALL ENTRANCES COMPLY WITH
 404, ENTRANCES COMPLYING WITH 404 SHALL BE IDENTIFIED
 BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING
 WITH 703.7.2.1. DIRECTIONAL SIGNS COMPLYING WITH 703.5
 THAT INDICATE THE LOCATION OF THE NEAREST ENTRANCE
 COMPLYING WITH 404 SHALL BE PROVIDED AT ENTRANCES THAT
 DO NOT COMPLY WITH 404.
 ADVISORY 216.6 ENTRANCES.WHERE A DIRECTIONAL SIGN IS
 REQUIRED, IT SHOULD BE LOCATED TO MINIMIZE
 BACKTRACKING. IN SOME CASES, THIS COULDMEAN LOCATING A
 SIGN AT THE BEGINNING OF A ROUTE, NOT JUST AT THE
 INACCESSIBLE ENTRANCES TO A BUILDING.
 - ADD NOTE FOR SIGNAGE TO DIRECT TO LOCATION OF NEAREST
 ACCESSIBLE ENTRANCE. SIGNAGE TO MEET REQUIREMENMTS OF
 703.5
  
 7) 503 FBC(A)PASSENGER LOADING ZONES.
 - PLEASE SHOW MARKED AREA 5' X 20' AND SLOPES TO COMPLY
 WITH 503.4 FLOOR AND GROUND SURFACES. (A CIVIL DRAWING
 COULD BE PROVIDED TO SHOW SLOPES AND CURB CUT)
  
 8) 502.5 FBC[A] VERTICAL CLEARANCE. PARKING SPACES FOR
 VANS AND ACCESS AISLES AND VEHICULAR ROUTES SERVING
 THEM SHALL PROVIDE A VERTICAL CLEARANCE OF 98 INCHES
 MINIMUM.
 - VERIFY THAT GARAGE PROVIDES VAN CLEARANCE OF 98
 INCHES MINIMUM.
  
 9) 803.4 FBC[A] BENCHES. A BENCH COMPLYING WITH 903
 SHALL BE PROVIDED WITHIN THE ROOM.
  
 903.4 FBC[A] BACK SUPPORT. THE BENCH SHALL PROVIDE FOR
 BACK SUPPORT OR SHALL BE AFFIXED TO A WALL. BACK
 SUPPORT SHALL BE 42 INCHES LONG MINIMUM AND SHALL
 EXTEND FROM A POINT 2 INCHES MAXIMUM ABOVE THE SEAT
 SURFACE TO A POINT 18 INCHES MINIMUM ABOVE THE SEAT
 SURFACE. BACK SUPPORT SHALL BE 21/2 INCHES MAXIMUM FROM
 THE REAR EDGE OF THE SEAT MEASURED HORIZONTALLY.
  
 OCCUPANCY:
  
 10) 107.5.3 FBC[AMENDED] GENERAL. SHEET LS-0.1
 - THE A-2 TAG AND FINE DINING TAGS ARE SHOWING POUND
 SIGNS INSTEAD OF THE SQ. FOOTAGE. PLEASE UPDATE SO THE
 SQ. FOOTAGE OF A-2 OCCUPANCY IS KNOWN.
  
 11) 303.3 FBC[B] GENERAL. SHEET LS-0.1
 - REVIEW GROUP A-2 THAT STATES DINING FACILITIES
 INCLUDING COMMERCIAL KITCHENS. SHOULD THE KITCHEN NOT
 BE CONSIDERED A-2 INSTEAD OF BUSINESS SINCE THE AREA
 SERVICED IS GREATER THAN 2500 SQ. FT.(SEE SECTION 304).
 HOWEVER, FOR EGRESS THEY YOU CAN USE OCCUPANT LOAD FOR
 COMMERCIAL KITCHEN THAT IS 200 GROSS PER TABLE 1004.1.2
  
 12) 107.5.3 FBC[AMENDED] GENERAL. SHEET LS-0.
 - OCCUPANY CLASSIFICATIONS ARE LISTED AS I-1, A-3, B,
 S-2 AND R-2, BUT WHEN I LOOK BELOW AT EXITING DATA I DO
 NOT SEE ALL THOSE OCCUPACIES LISTED. PLEASE UPDATE
 EXITING DATA TO MATCH ALL OCCUPANCY CLASSIFICATIONS.
  
 SITEWORK:
  
 13) 107.3.5.3 FBC[AMENDED] PROVIDE SEDIMENT CONTROL TO
 KEEP CONSTRUCTION DEBRIS FROM ENTERING ADJACENT
 PROPERTIES AND STORM DRAINS DURING CONSTRUCTION. YOU
 CAN JUST ADD SILT FENCE DETAIL AND HOW DRAINS ARE
 PROTECTED TO THE DRAINAGE PLAN. SOME ENGINEERING
 STANDARD DETAILS CAN BE USED FROM WPB WEBSITE-POLLUTION
 CONTROL. HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUB
 LIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 14) 107.3.5.3 FBC[AMENDED] PAVING AND DRAINAGE PLANS
 - PROVIDE CIVIL PLANS TO SHOW SLOPES, ELEVATIONS AND
 DRAINAGE AS IT RELATES TO PEDESTRIAN PATHWAYS AND
 ACCESS(FULL SET NOT REQUIRED)
  
 15) 107.5.3 FBC[AMENDED] SEPARATE PERMIT REQUIRED FOR
 VIBRO COMPACTION.
 - GEOTECHNICAL REPORT (RECEIVED, VIBRO-COMPACTION PROBE
 LAYOUT, FOUNDATION PLAN, AND STORM WATER POLLUTION
 PREVENTION PLAN (REQUESTED)
  
 16) 406.5.2 FBC(B)OPENINGS IN INTERIOR WALLS FOR OPEN
 PARKING.
 - PLEASE ADD OPENING PERCENTAGES FOR INTERIOR.WALLS OF
 OPEN GARAGE. SHEET LS-0.2 DOESN'T APPEAR TO HAVE
 OPENINGS ON INTERIOR WALL.
  
 17) 1609.4.3 FBC[B] EXPOSURE CATEGORIES. AN EXPOSURE
 CATEGORY SHALL BE DETERMINED IN ACCORDANCE WITH THE
 FOLLOWING: EXPOSURE B. FOR BUILDINGS WITH A MEAN ROOF
 HEIGHT OF LESS THAN OR EQUAL TO 30 FEET, EXPOSURE B
 SHALL APPLY WHERE THE GROUND SURFACE ROUGHNESS, AS
 DEFINED BY SURFACE ROUGHNESS B, PREVAILS IN THE UPWIND
 DIRECTION FOR A DISTANCE OF AT LEAST 1,500 FEET. FOR
 BUILDINGS WITH A MEAN ROOF HEIGHT GREATER THAN 30 FEET,
 EXPOSURE B SHALL APPLY WHERE SURFACE ROUGHNESS B
 PREVAILS IN THE UPWIND DIRECTION FOR A DISTANCE OF AT
 LEAST 2,600 FEET OR 20 TIMES THE HEIGHT OF THE
 BUILDING, WHICHEVER IS GREATER.
 EXPOSURE C. EXPOSURE C SHALL APPLY FOR ALL CASES WHERE
 EXPOSURE B OR D DOES NOT APPLY.
 EXPOSURE D. EXPOSURE D SHALL APPLY WHERE THE GROUND
 SURFACE ROUGHNESS, AS DEFINED BY SURFACE ROUGHNESS D,
 PREVAILS IN THE UPWIND DIRECTION FOR A DISTANCE OF AT
 LEAST 5,000 FEET OR 20 TIMES THE HEIGHT OF THE
 BUILDING, WHICHEVER IS GREATER. EXPOSURE D SHALL ALSO
 APPLY WHERE THE GROUND SURFACE ROUGHNESS IMMEDIATELY
 UPWIND OF THE SITE IS B OR C, AND THE SITE IS WITHIN A
 DISTANCE OF 600 FEET OR 20 TIMES THE BUILDING HEIGHT,
 WHICHEVER IS GREATER, FROM AN EXPOSURE D CONDITION AS
 DEFINED IN THE PREVIOUS SENTENCE.
 - IN REVIEWING LOCATION I WOULD PUT THIS LOCATION AT A
 CATEGORY C INSTEAD OF D. PLEASE REVIEW THIS WITH NEXT
 COMMENT ABOUT CATEGORY SELECTION AND PLEASE ADJUST IF
 APPLICABLE. PLEASE CONSIDER EXPOSURE C WITH CATEGORY
 III DESIGNATION OR PROVIDE JUSTIFICATION FOR THE
 CURRENT CATEGORY II SELCTION WITH D EXPOSURE.
  
 18) 1604.5 FBC[B] RISK CATEGORY. EACH BUILDING AND
 STRUCTURE SHALL BE ASSIGNED A RISK CATEGORY IN
 ACCORDANCE WITH TABLE 1604.5. WHERE A REFERENCED
 STANDARD SPECIFIES AN OCCUPANCY CATEGORY, THE RISK
 CATEGORY SHALL NOT BE TAKEN AS LOWER THAN THE OCCUPANCY
 CATEGORY SPECIFIED THEREIN. WHERE A REFERENCED STANDARD
 SPECIFIES THAT THE ASSIGNMENT OF A RISK CATEGORY BE IN
 ACCORDANCE WITH ASCE 7, TABLE 1.5-1, TABLE 1604.5 SHALL
 BE USED IN LIEU OF ASCE 7, TABLE 1.5-1. 1604.5.1
 MULTIPLE OCCUPANCIES.
 - TABLE 1604.5 FBC[B]. PLEASE REVIEW CRITERIA FOR
 CATEGORY II BEING SELECTED. CATEGORY III IS USED FOR
 BUILDINGS THAT REPRESENT A SUBSTAINTIAL HAZARD TO HUMAN
 LIFE. THIS BUILDING HAS HIGH OCCUPANT LOAD, OCCUPANTS
 UNDER CUSTODIAL CARE AND OCCUPANTS UNDER MEMORY CARE.
  
 19)3202.2 FBC[B]ENCROACHMENTS ABOVE GRADE AND BELOW 8
 FEET IN HEIGHT. ENCROACHMENTS INTO THE PUBLIC
 RIGHT-OF-WAY ABOVE GRADE AND BELOW 8 FEET (2438 MM) IN
 HEIGHT SHALL BE PROHIBITED EXCEPT AS PROVIDED FOR IN
 SECTIONS 3202.2.1 THROUGH 3202.2.3. DOORS AND WINDOWS
 SHALL NOT OPEN OR PROJECT INTO THE PUBLIC RIGHT-OF-WAY.
 - CHECK DOOR FROM STAIR 3 APPEARS TO CROSS PROPERTY
 LINES.
  
 20) 3002.4 FBC[B] ELEVATOR CAR TO ACCOMMODATE AMBULANCE
 STRETCHER. ANY BUILDING THAT IS MORE THAN THREE STORIES
 HIGH OR IN WHICH THE VERTICAL DISTANCE BETWEEN THE
 BOTTOM TERMINAL LANDING AND THE TOP TERMINAL LANDING
 EXCEEDS 25 FEET (7620 MM), MUST BE CONSTRUCTED TO
 CONTAIN AT LEAST ONE PASSENGER ELEVATOR THAT IS
 OPERATIONAL FOR BUILDING OCCUPANTS AND FIRE DEPARTMENT
 EMERGENCY ACCESS TO ALL FLOORS. THE ELEVATOR CAR SHALL
 BE OF SUCH A SIZE AND ARRANGEMENT TO ACCOMMODATE AN
 AMBULANCE STRETCHER 24 INCHES BY 76 INCHES (610 MM BY
 1950 MM) WITH NOT LESS THAN 5-INCH (127 MM) RADIUS
 CORNERS, IN THE HORIZONTAL, OPEN POSITION AND SHALL BE
 IDENTIFIED BY THE INTERNATIONAL SYMBOL FOR EMERGENCY
 MEDICAL SERVICES (STAR OF LIFE). THE SYMBOL SHALL BE
 NOT LESS THAN 3 INCHES (76 MM) IN HEIGHT AND SHALL BE
 PLACED INSIDE ON BOTH SIDES OF THE HOISTWAY DOOR FRAME.
 - INDICATE WHICH PASSENGER ELEVATOR WILL BE IDENTIFIED
 TO ACCOMMODATE STRETCHER.
  
 ASSEMBLIES:
  
 21) PLEASE PROVIDE OR STATE WHERE TO FIND TESTED
 ASSEMBLIES FOR FIRE RATED SPECIFIED IN TABLE 601 FOR
 FLOORS AND OTHER RATED ASSEMBLIES AS REQUIRED FROM
 TABLE 601.
  
 SUBMITTALS:
  
 22) 1014 FBC [B] GUARDS AND HANDRAILS. 1607.8 FBC [B]
 LOADS ON HANDRAILS AND GUARDRAILS. PROVIDE HANDRAIL AND
 GUARDRAIL ENGINEERING, OR INDICATE THAT YOU WOULD LIKE
 IT DEFERRED.
  
 107.3.4.1 FBC[AMENDED] DEFERRAL OF ANY SUBMITTAL ITEMS
 SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL FOR
 REVIEW, AND THEN FORWARED TO THE BUILDING OFFICIAL
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE
 INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN APPROVED BY THE BUILDING OFFICIAL.
  
 107.3.4.1 FBC[AMENDED] IF ANY SPEC SHEETS OR PRODUCT
 APPROVALS ARE ADDED, PLEASE UPLOAD THEM AS MULTIPAGE
 FORMAT PDF IN SUPPORTING DOCUMENTS.
  
 23) 806.3 FBC[B] COMBUSTIBLE DECORATIVE MATERIALS. IN
 OTHER THAN GROUP I-3, CURTAINS, DRAPERIES, FABRIC
 HANGINGS AND SIMILAR COMBUSTIBLE DECORATIVE MATERIALS
 SUSPENDED FROM WALLS OR CEILINGS SHALL COMPLY WITH
 SECTION 806.4 AND SHALL NOT EXCEED 10 PERCENT OF THE
 SPECIFIC WALL OR CEILING AREA TO WHICH SUCH MATERIALS
 ARE ATTACHED. FIXED OR MOVABLE WALLS AND PARTITIONS,
 PANELING, WALL PADS AND CRASH PADS APPLIED STRUCTURALLY
 OR FOR DECORATION, ACOUSTICAL CORRECTION, SURFACE
 INSULATION OR OTHER PURPOSES SHALL BE CONSIDERED
 INTERIOR FINISH SHALL COMPLY WITH SECTION 803 AND SHALL
 NOT BE CONSIDERED DECORATIVE MATERIALS OR FURNISHINGS.
 - (SEE 806.3 FOR EXCEPTIONS)
  
 806.4 FBC[B] ACCEPTANCE CRITERIA AND REPORTS. WHERE
 REQUIRED TO EXHIBIT IMPROVED FIRE PERFORMANCE,
 CURTAINS, DRAPERIES, FABRIC HANGINGS AND SIMILAR
 COMBUSTIBLE DECORATIVE MATERIALS SUSPENDED FROM WALLS
 OR CEILINGS SHALL BE TESTED BY AN APPROVED AGENCY AND
 MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF TEST
 1 OR 2, AS APPROPRIATE, OF NFPA 701, OR EXHIBIT A
 MAXIMUM HEAT RELEASE RATE OF 100 KW WHEN TESTED IN
 ACCORDANCE WITH NFPA 289, USING THE 20 KW IGNITION
 SOURCE. REPORTS OF TEST RESULTS SHALL BE PREPARED IN
 ACCORDANCE WITH THE TEST METHOD USED AND FURNISHED TO
 THE BUILDING OFFICIAL UPON REQUEST.
  -PROVIDE AS SUBMITTAL TO DEVELOPMENT SERVICES OFFICE
  
 24) 1207.2 FBC[B] FLOORING SUBMITTAL.
 - TYPE OF CEILING ASSEMBLY INCLUDING THICKNESS OF
 CONCRETE AND IF THERE IS A SOUND RATED ASSEMBLY IN UNIT
 BELOW.
  
 1207.2 FBC[B] PLEASE ADVISE ,VIA EMAIL, WHAT FLOORING
 AND UNDERLAYMENT ARE PROPOSED? IF THE UNDERLAYMENT
 PRODUCT PROPOSED IS NOT ONE FOR WHICH WE HAVE TEST
 REPORTS ON FILE, THE FOLLOWING REPORTS WILL BE
 REQUIRED:
 1207.2 FBC[B] AIR-BORNE SOUND. WALLS, PARTITIONS AND
 FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS AND
 SLEEPING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS OF
 NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED,
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E90.
 1207.3 FBC[B] STRUCTURE-BORNE SOUND. FLOOR/CEILING
 ASSEMBLIES BETWEEN DWELLING UNITS AND SLEEPING UNITS OR
 BETWEEN A DWELLING UNIT OR SLEEPING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS RATING OF NOT LESS THAN 50, OR
 NOT LESS THAN 45 IF FIELD TESTED, WHEN TESTED IN
 ACCORDANCE WITH ASTM E492.
 603.1 FBC[B] ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
 804.1 FBC[B] GENERAL. INTERIOR FLOOR FINISH AND FLOOR
 COVERING MATERIALS SHALL COMPLY WITH SECTIONS 804.2
 THROUGH 804.4.2. EXCEPTION: FLOOR FINISHES AND
 COVERINGS OF A TRADITIONAL TYPE, SUCH AS WOOD, VINYL,
 LINOLEUM OR TERRAZZO, AND RESILIENT FLOOR COVERING
 MATERIALS THAT ARE NOT COMPRISED OF FIBERS.
  
 TEMPORARY CONSTRUCTION:
  
 25) 3104.1.1 FBC[B] APPLICATION. PEDESTRIAN WALKWAYS
 SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
 SECTIONS 3104.2 THROUGH 3104.9. TUNNELS SHALL BE
 DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH SECTIONS
 3104.2 AND 3104.10.
 - SEPARATE PERMIT NEEDED TEMP FENCING AND RIGHT OF WAY
 PERMIT FOR SIDEWALK CLOSURES.
  
 26) 3306.1 FBC[B] PROTECTION REQUIRED. PEDESTRIANS
 SHALL BE PROTECTED DURING CONSTRUCTION, REMODELING AND
 DEMOLITION ACTIVITIES AS REQUIRED BY THIS CHAPTER AND
 TABLE 3306.1. SIGNS SHALL BE PROVIDED TO DIRECT
 PEDESTRIAN TRAFFIC. 3306.2 FBC[B] WALKWAYS. A WALKWAY
 SHALL BE PROVIDED FOR PEDESTRIAN TRAVEL IN FRONT OF
 EVERY CONSTRUCTION AND DEMOLITION SITE UNLESS THE
 APPLICABLE GOVERNING AUTHORITY AUTHORIZES THE SIDEWALK
 TO BE FENCED OR CLOSED. WALKWAYS SHALL BE OF SUFFICIENT
 WIDTH TO ACCOMMODATE THE PEDESTRIAN TRAFFIC, BUT IN NO
 CASE SHALL THEY BE LESS THAN 4 FEET (1219 MM) IN WIDTH.
 WALKWAYS SHALL BE PROVIDED WITH A DURABLE WALKING
 SURFACE. WALKWAYS SHALL BE ACCESSIBLE IN ACCORDANCE
 WITH CHAPTER 11 AND SHALL BE DESIGNED TO SUPPORT ALL
 IMPOSED LOADS AND IN NO CASE SHALL THE DESIGN LIVE LOAD
 BE LESS THAN 150 POUNDS PER SQUARE FOOT (PSF)
  
 27) 3306.7 FBC[B] COVERED WALKWAYS. COVERED WALKWAYS
 SHALL HAVE A CLEAR HEIGHT OF NOT LESS THAN 8 FEET (2438
 MM) AS MEASURED FROM THE FLOOR SURFACE TO THE CANOPY
 OVERHEAD. ADEQUATE LIGHTING SHALL BE PROVIDED AT ALL
 TIMES. COVERED WALKWAYS SHALL BE DESIGNED TO SUPPORT
 ALL IMPOSED LOADS. IN NO CASE SHALL THE DESIGN LIVE
 LOAD BE LESS THAN 150 PSF (7.2 KN/M2) FOR THE ENTIRE
 STRUCTURE.
  
 PROVISOS:
  
 A) AIPP COMPLIANCE REQUIRED; VERIFICATION REQUIRED
 PRIOR TO C.O.
 B) DEFERRED SUBMITTALS - COMPONENT & CLADDING PRODUCT
 APPROVALS SUBMITTED TO PLAN REVIEW OFFICE. PRODUCT
 APPROVALS FOR LOUVERS AND EQUIPMENT STANDS.
 C) VEHICLE BARRIER SUBMITTAL TO PLAN REVIEW OFFICE
 D) ROOF ENGINEERING AND PRODUCT APPOVAL TO BE SUBMITTED
 WITH ROOF SUB-PERMIT APPLICATION. SEE ENERGY
 CALCULATIONS THAT CALL FOR HIGH ALBEDO ROOF.
 E) SEPARATE PERMITS REQUIRED FOR - GENERATOR, LIGHT
 POLES/SITE LIGHTING, FIRE ALARM, FIRE SPRINKLER, LOW
 VOLTAGE, ACCESS, LANDSCAPING, IRRIGATION, POOL,
 TEMPORARY FENCE AND RIGHT OF WAY PERMITS(ENGINEERING)
 F) CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM
 SAT-SUN
 - NO RESPONSE REQUIRED. THESE WILL BE ADDED TO THE
 PLANS AT FINAL STAMPING.
  
 NOTES:
  
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F 8-5) TO
 DISCUSS COMMENTS, OR E-MAIL ANYTIME [email protected]
  
  
  
2020-04-30 15:41:59 
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-11-16 Cont ID  
Sent By jleahy Date 2020-11-16 Time 14:14 Rev Time 0.00
Received By jleahy Date 2020-11-16 Time 14:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-10-20 Cont ID  
Sent By jleahy Date 2020-10-20 Time 17:16 Rev Time 0.00
Received By jleahy Date 2020-10-16 Time 12:28 Sent To  
Notes
2020-10-20 17:19:41ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 FEEDER OFF GENERATOR GOES INTO GEPD DOES THIS CONFORM
 TO 700.10? IF SO PLEASE EXPLAIN, SHOULD IT NOT BE IN
 SEPARATE VERTICAL SWITCHBOARD SECTIONS?

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By shill Date 2020-08-20 Time 16:10 Rev Time 0.00
Received By shill Date 2020-08-20 Time 16:10 Sent To  
Notes
2020-07-20 12:09:29CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLANS ARE LABELED AS NOT FOR CONSTRUCTION. TO BE
 USED FOR PERMIT THE PLANS MUST BE 100% COMPLETE AND
 THIS STATEMENT MUST NOT BE PRESENT. PROVIDE CORRECTION.
 WPB FBC 105.1, 107.2.1
 2. FIRE ALARM, LOW VOLTAGE SYSTEMS, DAS, LIGHTNING
 PROTECTION, GENERATORS, COMMERCIAL HOOD SYSTEMS, WALK
 IN COOLERS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS
 (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF
 THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND PLAN SUBMITTALS FOR ANY
 OF THESE SYSTEMS PRESENT. WPB FBC 105.1, 107.2.1
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE AND DOWNSTREAM PANELS, INCLUDING INFORMATION
 FROM THE POWER COMPANY, STATING WHAT THE AVAILABLE
 SHORT CIRCUIT CURRENT IS FOR THE SERVICE AND DOWNSTREAM
 PANELS TO CONFIRM THE STATED AIC RATING OF THE
 ELECTRICAL EQUIPMENT IS ADEQUATE. CALCULATIONS SHOULD
 BE PERFORMED UNTIL THEY REACH BELOW 10,000 AIC. NEC
 110.9, 110.10
 4. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES
 EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN
 RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR
 LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2
 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 6. PROVIDE VOLTAGE DROP CALCULATIONS TO COMPLY WITH
 CODE. FBC EC C405.6.3
 7. PROVIDE ENCLOSURE FOR POOL PANEL ADEQUATE FOR THE
 ENVIRONMENT. NEC TABLE 110.28
 8. IT APPEARS THAT NEC 220.84 WAS USED FOR CALCULATIONS
 FOR ALL RESIDENTIAL SERVICES. THIS METHOD IS PERMITTED
 ONLY WHERE THE UNITS ARE EQUIPPED WITH ELECTRIC COOKING
 EQUIPMENT. THIS IS NOT THE CASE FOR ALL UNITS. PROVIDE
 ACCURATE LOAD CALCULATION INCLUDING ALL LOADS. NEC
 220.84
 9. PROVIDE ACCURATE LOAD CALCULATION AND PANEL SCHEDULE
 FOR PANEL GEDP. WHAT WILL THE LOAD ON THE GENERATOR BE?
 NEC 220
 10. PROVIDE DETAILS OF COMPLIANCE WITH THE EMERGENCY
 ENVIRONMENTAL CONTROL REQUIRED PER FLORIDA
 ADMINISTRATIVE CODE, RULE 58A-5.036
 11. SHEET E-7.2 STATES THE GENERATOR DESIGN IS BASED ON
 NEC 702, WHICH IS FOR OPTIONAL STANDBY SYSTEMS. THIS IS
 A LEGALLY REQUIRED SYSTEM. PROVIDE CLARIFICATION AND/OR
 CORRECTIONS. NEC 701.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 [email protected]
 JAKE LEAHY
 561-805-6713
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status   Date 2022-02-23 Cont ID  
Sent By jleahy Date 2020-11-16 Time 14:18 Rev Time 0.00
Received By jleahy Date 2020-11-16 Time 14:18 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2020-07-16 Cont ID  
Sent By Mgonzale Date 2020-07-16 Time   Rev Time 1.00
Received By mgonzale Date 2020-07-16 Time   Sent To I
Notes
2020-07-16 14:23:48PROJECT HAS SATIFIED ENGINEERING DEVELOPEMNT REVIEW.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2020-07-09 Cont ID  
Sent By rrossano Date 2020-07-09 Time   Rev Time  
Received By rrossano Date 2020-07-09 Time   Sent To I
Notes
2020-07-09 20:28:35UNDER REVIEW AS FORMAL ENGINEERING SUBMITTAL E20010032.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2020-11-06 Cont ID  
Sent By pleduc Date 2020-11-06 Time   Rev Time 0.00
Received By pleduc Date 2020-11-06 Time 16:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-07-08 Cont ID  
Sent By pleduc Date 2020-07-08 Time   Rev Time 0.00
Received By pleduc Date 2020-07-07 Time 10:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-06-25 Cont ID  
Sent By pleduc Date 2020-06-25 Time   Rev Time 0.00
Received By pleduc Date 2020-06-19 Time 10:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-05-22 Cont ID  
Sent By pleduc Date 2020-05-22 Time   Rev Time 0.00
Received By pleduc Date 2020-05-11 Time 14:36 Sent To  
Notes
2020-05-20 14:32:46 
  
  
  
 1) 1ST FLOOR MECHANICAL SHEETS - THERE DOES NOT APPEAR
 TO BE ANY FIRE DAMPERS INDICATED WHERE DUCT PENETRATES
 THROUGH A FIRE RATED WALL; LAUNDRY ROOM; VOID SPACE
 WALL.
  
 NFPA 101 , CH 32, NEW RESIDENTIAL BOARD AND CARE
 OCCUPPANCIES
  
 32.3.6.2 HEATING, VENTILATING, AND AIR-CONDITIONING.
 32.3.6.2.1 HEATING, VENTILATING, AND AIR-CONDITIONING
 EQUIPMENT
 SHALL COMPLY WITH SECTION 9.2.
  
 NFPA 101, CH 9
  
 9.2 HEATING, VENTILATING, AND AIR-CONDITIONING.
 9.2.1 AIR-CONDITIONING, HEATING, VENTILATING DUCTWORK,
 AND
 RELATED EQUIPMENT. AIR-CONDITIONING, HEATING,
 VENTILATING DUCTWORK,
 AND RELATED EQUIPMENT SHALL BE IN ACCORDANCE WITH NFPA
 90A,
 STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND
 VENTILATING
 SYSTEMS, OR NFPA 90B, STANDARD FOR THE INSTALLATION OF
 WARM AIR
 HEATING AND AIR-CONDITIONING SYSTEMS, AS APPLICABLE,
 UNLESS SUCH
 INSTALLATIONS ARE APPROVED EXISTING INSTALLATIONS,
 WHICH SHALL BE
 PERMITTED TO BE CONTINUED IN SERVICE.
  
 NFPA 90A
  
 4.3.9 FIRE DAMPERS.
 4.3.9.1 APPROVED FIRE DAMPERS SHALL BE PROVIDED AS
 REQUIRED
 IN CHAPTER 5.
 4.3.9.2 APPROVED FIRE DAMPERS SHALL BE INSTALLED IN
 CONFORMANCE
 WITH THE CONDITIONS OF THEIR LISTINGS.
  
 5.3* PENETRATIONS ? PROTECTION OF OPENINGS.
 5.3.1 FIRE-RATED WALLS AND PARTITIONS.
 5.3.1.1* APPROVED FIRE DAMPERS SHALL BE PROVIDED WHERE
 AIR
 DUCTS PENETRATE OR TERMINATE AT OPENINGS IN WALLS OR
 PARTITIONS
 REQUIRED TO HAVE A FIRE RESISTANCE RATING OF 2 HOURS OR
 MORE.
 5.3.1.1.1* FIRE DAMPERS SHALL NOT BE REQUIRED WHERE
 OTHER
 OPENINGS THROUGH THE WALL ARE NOT REQUIRED TO BE
 PROTECTED.
 5.3.1.2 APPROVED FIRE DAMPERS SHALL BE PROVIDED IN ALL
 AIR
 TRANSFER OPENINGS IN PARTITIONS THAT ARE REQUIRED TO
 HAVE A FIRE
 RESISTANCE RATING AND IN WHICH OTHER OPENINGS ARE
 REQUIRED TO
 BE PROTECTED.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC CODE
 REFERNCES.
  
  
 1A) THROUGHOUT THE UPPER FLOORS THERE ARE INDICATIONS
 OF FIRE AND SMOKE DAMPER WITHIN 1 HOUR RATED WALLS;
 HOWEVER, ON THE 1ST FLOOR THERE ARE NO INDICATIONS OF
 FIRE AND SMOKE DAMPERS WHERE A/C DUCT APPEAR TO
 PENETRATE THESE RATED WALLS.
  
 PLEASE REVIEW AND JUSTIFY OR CORRECT.
  
  
  
 1B) A CLEAR SEQUENCE OF OPERATION OF THE FIRE/SMOKE
 DAMPERS COULD NOT BE LOCATED.
  
 PLEASE PROVIDE A SOO FOR EACH
 DAMPER/FLOOR/FLOORS/ENTIRE BUILDING INCLUING ACTIVATION
 OF THE FIRE ALARM.
  
  
  
  
 2) FLOOR PLAN SHEETS - THERE ARE NO INDICATIONS OF THE
 WIDTH OF THE CORRIDORS ON ANY FLOOR.
  
 32.3.2.3.3 THE WIDTH OF CORRIDORS SHALL BE SUFFICIENT
 FOR THE
 OCCUPANT LOAD SERVED BUT SHALL BE NOT LESS THAN 60 IN.
  
 PLEASE PROVIDE WIDTH DIMENSIONS IN COMPLIANCE.
  
  
  
 3) SHEET LS 05 & 06 THRU 8 - THE VEST. DOOR FOR
 ELEVATOR # 3 IS INDICATED AS OUTSWING INTO THE EGRESS
 CORRIDOR.
  
 PER NFPA 101, CH 7 MEANS OF EGRESS
  
 PER NFPA 101 CHAPTER 7, MEANS OF EGRESS
 7.2.1.4.3 DOOR LEAF ENCROACHMENT
 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE
 REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY,
 OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT
 MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A
 CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN,
 UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET:
 (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN
 EXISTING BUILDING.
 (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS
 PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED
 WIDTH OF THE STAIR LANDING WHEN THE DOOR
 LEAF IS FULLY OPEN.
  
 PLEASE CORRECT OR JUSTIFY WITH SPECIFIC CODE REFERNCES.
  
  
 4) SHEET LS 05 - THE EXIT DOOR FROM THE POOL DECK ON
 THE WEST SIDE IS INDICATED AS OUTSWING INTO THE EGRESS
 CORRIDOR.
  
 PER NFPA 101, CH 7 MEANS OF EGRESS
  
 PER NFPA 101 CHAPTER 7, MEANS OF EGRESS
 7.2.1.4.3 DOOR LEAF ENCROACHMENT
 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE
 REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY,
 OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT
 MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A
 CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN,
 UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET:
 (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN
 EXISTING BUILDING.
 (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS
 PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED
 WIDTH OF THE STAIR LANDING WHEN THE DOOR
 LEAF IS FULLY OPEN.
  
 PLEASE CORRECT OR JUSTIFY WITH SPECIFIC CODE REFERNCES.
  
  
  
 5) ALL ELECTRICAL SHEETS - WHERE EXIT SIGNS ARE LOCATED
 ON BOTH SIDES OF A OPPISITE SWINGING DOUBLE DOORS, THE
 EXIT SIGNS SHALL BE PLAC OVER THE CENTER OF THE DOOR IN
 THE PATH OF TRAVEL.
  
 PLEAS CORRECT ALL LOCATIONS.
  
  
  
 6) SHEET E 2.5A - IN THE CORNER OF THE RIDER AT THE
 DOUBLE DOORS INTO THE SKY LOUNGE THERE IS AN EXIT SIGN
 DIRECTLY OVER THE OUTSWING DOUBLE DOOR WITH A CHEVRON
 INDICATED AWAY/TO THE RIGHT FROM THAT DOOR TOWARDS THE
 STAIR. THIS CONFIGURATION MAY LEAD TO PEOPLE THINKING
 THEY COULD EXIT THROUGH THOSE DOUBLE DOORS.
  
 THE EXIT SIGN SHOULD BE MOVED OUT AWAY FROM DIRECTLY
 OVER THOSE DOORS TO THE CENTER/RIGHT (OFF-CENTER) OF
 THE CORRIDOR CLOSE TO THE EDGE LINE OF THE VEST.
 CORRIDOR WALL.
  
  
 6A) SHEET E 2.5A - WITHIN THE SKY LOUNGE THERE IS AN
 EXIT SIGN DIRECTLY OUTSIDE THE DOUBLE DOORS COMING FROM
 THE POOL. THIS SIGN APPEARS TO BE UNNECESSARY AND CAN
 BE REMOVED.
  
 PLEASE REVIEW AND CONSIDER REMOVING UNLESS YOU CAN
 JUSTIFY IT.
  
  
  
 7) SHEET E 2.5B - WITHIN THE CORRIDOR THERE IS AN EXIT
 SIGN DIRECTLY OUTSIDE THE DOUBLE DOORS COMING FROM THE
 POOL. THIS SIGN APPEARS TO BE UNNECESSARY AND CAN BE
 REMOVED.
  
 PLEASE REVIEW AND CONSIDER REMOVING UNLESS YOU CAN
 JUSTIFY IT.
  
  
  
 8) SHEET E 2.5B - AT THE WEST END OF THE POOL THERE IS
 A CORRIDOR LEADING TO THE INTERIOR; THERE IS AN EXIT
 SIGNIN THE MIDDLE OF THAT CORRIDOR THAT ASPPEARS TO BE
 MISLOCATED AND NOT VISIBLE TO POOL ATTENDEES.
  
 PLEASE REVIEW AND CORRECT.
  
  
 8A) SHEET E 2.5B - IF THEWEST EXTERIOR CORRIDOR FROM
 THE POOL AREA IS INTENDED TO BE AN EXIT AN EXIT SIGN
 SHALL BE PLACED AT THE ENTRANCE TO THAT CORRIDOR.
  
 PLEASE REVIEW AND CORRECT.
  
  
 8B) SHEET E 2.5B - THE NORTH DOUBLE DOOR EXIT FROM THE
 POOL AREA HAS AN EXIT SIGN DIRECTLY OVER IT THAT IS NOT
 VISIABLE FROM THE GENERAL OPEN POOL AREA. THIS EXIT
 SING NEEDS TO BE VISABLE FROM THE GENRAL POOL AREA.
  
 THIS EXIT SIGN CAN BE MOVED OUT FROM DIRECTLY OVER THE
 EXIT DOORS AND PLACED AT THE ENTRANCE TO THE SHORT
 CORRIDOR.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 9) SHEET E 2.6A - THERE IS NO EXIT SIGN LOCATED WITHIN
 THE VEST OF ELEVATOR # 3.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
  
 10) SHEET E2. 2A, 3A & 4A - THERE IS AND EXIT SIGN
 WITHIN THE STAIRWELL THAT LEADS TO THE PARKING GARAGE.
 IT SHOULD NOT BE INTENT TO LEAVE A PROTECTED STAIRWELL
 TO ENTER INTO A HIGHER HAZARD UNPROTECTED AREA.
  
 PER NFPA 101, CH 7 MEANS OF EGRESS
  
 7.2.3.5 DISCHARGE.
 7.2.3.5.1 EVERY SMOKEPROOF ENCLOSURE SHALL DISCHARGE
 INTO A PUBLIC
 WAY, INTO A YARD OR COURT HAVING DIRECT ACCESS TO A
 PUBLIC WAY, OR
 INTO AN EXIT PASSAGEWAY. SUCH EXIT PASSAGEWAYS SHALL BE
 WITHOUT
 OPENINGS, OTHER THAN THE ENTRANCE TO THE SMOKEPROOF
 ENCLOSURE AND
 THE DOOR OPENING TO THE OUTSIDE YARD, COURT, OR PUBLIC
 WAY. THE EXIT
 PASSAGEWAY SHALL BE SEPARATED FROM THE REMAINDER OF THE
 BUILDING
 BY A 2-HOUR FIRE RESISTANCE RATING.
  
 THIS DOOR CAN FUNCTION AS AN EXIT FROM THE GARAGE BY
 NOT BE OPERABLE FROM THE INSIDE OF THE STAIR NOT MARKED
 AS AN EXIT FROM THE WITHIN THE STAIR.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 10A) SHEET E2 2B & LS 0.2 - THERE IS NO INDICATION ON
 E2 2B OF AN EXIT SIGN AT THE EAST GARAGE EXIT DOOR TO
 STAIR # 2 AS IS INDICATED ON LS 0.2.
  
 PLEASE REVIEW AND CORRECT.
  
  
 11) SHEET E2 2.1A , A 2.1 & LS 0.1 - THERE IS A
 CONFLICT OF THE DISCHARG DESIGN OF STAIR # 2 AND THUS
 THE EXIT SIGNAGE. SHOULD A 2.1 & LS 0.1 BE CORRECT
 PLEASE MOVE THE EXIT SIGN FROM OVER THE DOOR TO THE
 AREA VISABLE THROUGH THE OPENING WITH A CHEVRON LEADING
 TO THE DOOR.
  
 PLEASE REVIEW AND CORRECT THE EXIT SIGN AND THE CORRECT
 FLOOR PLAN ACCORDINGLY.
  
  
  
 12) SHEET E2 2.1A - THERE IS AN INDICATION OF AN EXIT
 SIGN FROM THE WEST SIDE OF THE MAIN KITCHEN THAT IS NOT
 VISABLE FROM THE GENRAL KITCHEN ARE. AN ADDITIONAL EXIT
 SIGN NEEDS TO BE LOCATED OUT INTO THE MAIN KITCHEN AREA
 THAT LEADS TO THIS EXIT.
  
 PLEASE REVIEW AND CORRECT.
  
  
 13) SHEET E2 2.1B - THERE IS NO INDICATION OF AN EXIT
 SIGNS FROM THE PUMP ROOM, MDF/BDA ROOM, BOILER ROOM,
 MAIN ELECT ROOM, FPL VAULT, & GERNATOR ROOM.
  
 PLEASE REVIEW AND CORRECT.
  
  
 14) SHEET E2 2.1B - THERE IS NO INDICATION OF AN EXIT
 SIGNS FROM THE LARGE WOMEN AND MENS RESTOOMS NEAR THE
 EXERCISE ROOM.
  
 PLEASE REVIEW AND CORRECT.
  
  
 15) SHEET E2 2.1B - THERE IS NO INDICATION OF AN EXIT
 SIGN FROM THE BEAUTY SALON FOR THOSE WITH DISABILTY.
 THERE IS AN EXIT SIGN INDICATED WITHIN THE TREATMENT
 THAT CAN BE REMOVED AND RELOCATED AT THAT SMALL
 CORRIDOR EDGE SO THAT IT IS VISABLE FROM THE SALON.
 THERE IS ALSO AN EXIT SIGN DIRECTLY OUTSIDE THE SALON
 THAT CAN BE REMOVED.
  
 ADDITIONALLY, THERE IS CONFLICT OF THE LAYOUT OF RECEPT
 AREA COMPARED TO THE LS 0.1.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 16) SHEET E2 7A & 7B - THERE ARE NO INDICATIONS OF EXIT
 SIGNS AT EACH STAIRWELL NOR ALONG ANY DEFINED EXIT
 PATH.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
  
 17) SHEET LS 0.0 - UNDER DEFERRED SUBMITTALS # 5 THERE
 IS AN INDICATION OF PREFABRICATED WOOD ROOF TRUSSES;
 HOWEVER, THERE ARE NO INDICATION OF FIRE SPRINKLER
 PROTECTION ON THE ROOF, SHEET FS 2.7A & B.
  
 PER NFPA 13
  
 8.3.2.5* THE FOLLOWING PRACTICES SHALL BE OBSERVED TO
 PROVIDE
 SPRINKLERS OF OTHER THAN ORDINARY-TEMPERATURE
 CLASSIFICATION
 UNLESS OTHER TEMPERATURES ARE DETERMINED OR UNLESS
 HIGHTEMPERATURE
 SPRINKLERS ARE USED THROUGHOUT, AND TEMPERATURE
 SELECTION SHALL BE IN ACCORDANCE WITH TABLE 8.3.2.5(A),
 TABLE 8.3.2.5(B), AND FIGURE 8.3.2.5:
  
 (5) SPRINKLERS IN AN UNVENTILATED, CONCEALED SPACE,
 UNDER
 AN UNINSULATED ROOF, OR IN AN UNVENTILATED ATTIC SHALL
 BE
 OF THE INTERMEDIATE-TEMPERATURE CLASSIFICATION.
  
 8.6.4.1.4 SPRINKLERS UNDER ROOF OR CEILING IN
 COMBUSTIBLE
 CONCEALED SPACES OF WOOD JOIST OR WOOD TRUSS
 CONSTRUCTION
 WITH MEMBERS LESS THAN 3 FT (0.91 M) ON CENTER AND
 SLOPE
 HAVING PITCH OF 4 IN 12 OR GREATER. SPRINKLERS SHALL BE
 POSITIONED
 IN ACCORDANCE WITH FIGURE 8.6.4.1.4 AND THE
 REQUIREMENTS
 OF 8.6.4.1.4.1 THROUGH 8.6.4.1.4.5.
 8.6.4.1.4.1 SPRINKLERS UNDER A ROOF OR CEILING IN
 COMBUSTIBLE
 CONCEALED SPACES OF WOOD JOIST OR WOOD TRUSS
 CONSTRUCTION WITH
 MEMBERS LESS THAN 3 FT (0.91 M) ON CENTER AND A SLOPE
 HAVING A
 PITCH OF 4 IN 12 OR GREATER SHALL BE QUICK-RESPONSE.
 8.6.4.1.4.2 SPRINKLERS UNDER A ROOF OR CEILING IN
 COMBUSTIBLE
 CONCEALED SPACES OF WOOD JOIST OR WOOD TRUSS
 CONSTRUCTION WITH
 MEMBERS LESS THAN 3 FT (0.91 M) ON CENTER AND A SLOPE
 HAVING A
 PITCH OF 4 IN 12 OR GREATER SHALL BE INSTALLED SO THAT
 A ROW OF
 SPRINKLERS IS INSTALLED WITHIN 12 IN. (305 MM)
 HORIZONTALLY OF
 THE PEAK AND BETWEEN 1 IN. AND 12 IN. (25.4 MM AND 305
 MM)
 DOWN FROM THE BOTTOM OF THE TOP CHORD MEMBER.
 8.6.4.1.4.3 SPRINKLERS UNDER A ROOF OR CEILING IN
 COMBUSTIBLE
 CONCEALED SPACES OF WOOD JOIST OR WOOD TRUSS
 CONSTRUCTION WITH
 MEMBERS LESS THAN 3 FT (0.91 M) ON CENTER AND A SLOPE
 HAVING A
 PITCH OF 4 IN 12 OR GREATER SHALL BE INSTALLED SO THAT
 THE SPRINKLERS
 INSTALLED ALONG THE EAVE ARE LOCATED NOT LESS THAN 5 FT
 (1.52 M) FROM THE INTERSECTION OF THE UPPER AND LOWER
 TRUSS
 CHORDS OR THE WOOD RAFTERS AND CEILING JOISTS.
 8.6.4.1.4.4 SPRINKLERS UNDER A ROOF OR CEILING IN
 COMBUSTIBLE
 CONCEALED SPACES OF COMBUSTIBLE WOOD JOIST OR WOOD
 TRUSS CONSTRUCTION
 WITH MEMBERS LESS THAN 3 FT (0.91 M) ON CENTER AND A
 SLOPE HAVING A PITCH OF 4 IN 12 OR GREATER, AND USING
 STANDARD
 SPRAY SPRINKLERS, WHERE THE DIMENSION PERPENDICULAR TO
 THE
 SLOPE EXCEEDS 8 FT (2.4 M), SHALL HAVE A MINIMUM
 PRESSURE OF
 20 PSI (1.4 BAR).
 8.6.4.1.4.5 THE SPECIAL REQUIREMENTS OF 8.6.2.2.1 AND
 8.6.4.1.4
 FOR SPRINKLERS UNDER A ROOF OR CEILING IN COMBUSTIBLE
 CONCEALED
 SPACES OF WOOD JOIST OR WOOD TRUSS CONSTRUCTION WITH
 MEMBERS
 LESS THAN 3 FT (0.91 M) ON CENTER AND A SLOPE HAVING A
 PITCH OF 4 IN
 12 OR GREATER SHALL NOT APPLY WHEN THE EXPOSED
 COMBUSTIBLE
 SHEATHING IN THE ROOF OR CEILING SPACE ARE CONSTRUCTED
 OF PRESSURE
 IMPREGNATED FIRE-RETARDANT TREATED WOOD AS DEFINED BY
 NFPA703.
  
 8.15 SPECIAL SITUATIONS.
 8.15.1 CONCEALED SPACES.
 8.15.1.1 CONCEALED SPACES REQUIRING SPRINKLER
 PROTECTION.
 CONCEALED SPACES OF EXPOSED COMBUSTIBLE CONSTRUCTION
 SHALL
 BE PROTECTED BY SPRINKLERS EXCEPT IN CONCEALED SPACES
 WHERE
 SPRINKLERS ARE NOT REQUIRED TO BE INSTALLED BY
 8.15.1.2.1
 THROUGH 8.15.1.2.18 AND 8.15.6.
 8.15.1.2* CONCEALED SPACES NOT REQUIRING SPRINKLER
 PROTECTION.
 8.15.1.2.1* CONCEALED SPACES OF NONCOMBUSTIBLE AND
 LIMITEDCOMBUSTIBLE
 CONSTRUCTION WITH MINIMAL COMBUSTIBLE LOADING
 HAVING NO ACCESS SHALL NOT REQUIRE SPRINKLER
 PROTECTION.
 8.15.1.2.1.1 THE SPACE SHALL BE CONSIDERED A CONCEALED
 SPACE
 EVEN WITH SMALL OPENINGS SUCH AS THOSE USED AS RETURN
 AIR FOR A
 PLENUM.
 8.15.1.2.2 CONCEALED SPACES OF NONCOMBUSTIBLE AND
 LIMITEDCOMBUSTIBLE
 CONSTRUCTION WITH LIMITED ACCESS AND NOT PERMITTING
 OCCUPANCY OR STORAGE OF COMBUSTIBLES SHALL NOT REQUIRE
 SPRINKLER PROTECTION.
  
 8.15.1.2.9 CONCEALED SPACES OVER ISOLATED SMALL ROOMS
 NOT
 EXCEEDING 55 FT2 (5.1 M2) IN AREA SHALL NOT REQUIRE
 SPRINKLER
 PROTECTION.
  
 8.15.1.2.11* CONCEALED SPACES IN WHICH THE EXPOSED
 MATERIALS
 ARE CONSTRUCTED ENTIRELY OF FIRE RETARDANT?TREATED WOOD
 AS DEFINED
 BY NFPA 703 SHALL NOT REQUIRE SPRINKLER PROTECTION.
  
 PLEASE REVIEW AND PROVIDE SPRINKLER PROTECTION OR
 JUSTIFY WITH SPECIFIC CODE REFERNCES AND SPECIFIC
 DETALS THAT MEET OMMISSION REQUIREMENTS.
  
  
  
 18) FIRE ALARM SHEETS - THERE APPEARS TO BE AN OVER
 DESIGN OF THE SMOKE DETECTORS LOCATED THROUGHOUT THE
 FLOORS PLANS THAT MAY NOT BE REQUIRED. SMOKE DETECTORS
 INSTALLED WHERE NOT REQUIRED OR FOR A SPECIFIC PURPOSE
 MAY LEAD TO EXCESSIVE FALSE ALARMS AND MAINTENANCE.
  
 I'M NOT SURE WHAT CODE IS BEING USED FOR THIS
 OCCUPANCY; HOWEVER, PER NFPA 101, CH 32, NEW
 RESIDENTIAL BOARD OCCUPANCIES.
  
 32.3.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.
 32.3.3.4.1 GENERAL. A FIRE ALARM SYSTEM SHALL BE
 PROVIDED IN
 ACCORDANCE WITH SECTION 9.6.
 32.3.3.4.2 INITIATION. THE REQUIRED FIRE ALARM SYSTEM
 SHALL BE
 INITIATED BY EACH OF THE FOLLOWING:
 (1) MANUAL MEANS IN ACCORDANCE WITH 9.6.2
 (2) MANUAL FIRE ALARM BOX LOCATED AT A CONVENIENT
 CENTRAL CONTROL
 POINT UNDER CONTINUOUS SUPERVISION OF RESPONSIBLE
 EMPLOYEES
 (3) REQUIRED AUTOMATIC SPRINKLER SYSTEM
 (4) REQUIRED DETECTION SYSTEM
 32.3.3.4.7 SMOKE ALARMS. APPROVED SMOKE ALARMS SHALL BE
 INSTALLED IN ACCORDANCE WITH 9.6.2.10 INSIDE EVERY
 SLEEPING ROOM,
 OUTSIDE EVERY SLEEPING AREA IN THE IMMEDIATE VICINITY
 OF THE
 BEDROOMS, AND ON ALL LEVELS WITHIN A RESIDENT UNIT.
 32.3.3.4.8 SMOKE DETECTION SYSTEMS.
 32.3.3.4.8.1 CORRIDORS AND SPACES OPEN TO THE
 CORRIDORS, OTHER THAN
 THOSE MEETING THE REQUIREMENT OF 32.3.3.4.8.3, SHALL BE
 PROVIDED
 WITH SMOKE DETECTORS THAT COMPLY WITH NFPA 72, NATIONAL
 FIRE
 ALARM AND SIGNALING CODE, AND ARE ARRANGED TO INITIATE
 AN ALARM
 THAT IS AUDIBLE IN ALL SLEEPING AREAS.
 32.3.3.4.8.2 RESERVED.
 32.3.3.4.8.3 SMOKE DETECTION SYSTEMS SHALL NOT BE
 REQUIRED IN
 UNENCLOSED CORRIDORS, PASSAGEWAYS, BALCONIES,
 COLONNADES, OR
 OTHER ARRANGEMENTS WITH ONE OR MORE SIDES ALONG THE
 LONG
 DIMENSION FULLY OR EXTENSIVELY OPEN TO THE EXTERIOR AT
 ALL TIMES.
  
 I.E. LOCATIONS - 1ST FLOOR) KITCHEN, ENCLOSED AL
 DINING, LAUNDRY,LOCKERS 1ST FL, PACKAGE ROOM, VOID
 SPACE, THEATRE, MUTLTI FUNCTION AREA, DISCOVERY ROOM,
 LIBRARY, BEAUTY SALON, DIRECTOR OFFICE, EXAM TOILET,
 ETC.
 2ND FLOOR - STORAGE, PREPARATION KITCHEN,
 3RD FLOOR - LAUNDRY, GARAGE STORAGE
 4TH FLOOR - LAUNDRY, GARAGE STORAGE, MED DISP
 5TH FLOOR -SKY LOUNGE,
  
 PLEASE PROVIDE THE CODE USED THAT REQUIRED SD IN THESE
 LOCATIONS.
  
 PLEASE REVIEW AND REMOVE IN AN ATTEMPT TO REDUCE FALSE
 ALARMS AND STILL COMPLY WITH THE CODE.
  
  
  
 19) FIRE ALARM SHEETS - THERE ARE INDICATIONS OF MANUAL
 PULL STATIONS LOCATED THROUGHT THE BUILDING AT EXIT
 LOCATIONS.
  
 PER NFPA 101, CH 32
  
 32.3.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.
 32.3.3.4.1 GENERAL. A FIRE ALARM SYSTEM SHALL BE
 PROVIDED IN
 ACCORDANCE WITH SECTION 9.6.
  
 PER NFPA 101, CH 9
  
 9.6.2 SIGNAL INITIATION.
  
 9.6.2.6* FOR FIRE ALARM SYSTEMS USING AUTOMATIC FIRE
 DETECTION OR
 WATERFLOW DETECTION DEVICES TO INITIATE THE FIRE ALARM
 SYSTEM IN
 ACCORDANCE WITH CHAPTERS 11 THROUGH 43, NOT LESS THAN
 ONE MANUAL
 FIRE ALARM BOX, LOCATED AS REQUIRED BY THE AUTHORITY
 HAVING
 JURISDICTION, SHALL BE PROVIDED TO INITIATE A FIRE
 ALARM SIGNAL.
  
 THE * APPENDIX NARRATIVE STATES:
  
 A.9.6.2.6 THE MANUAL FIRE ALARM BOX REQUIRED BY 9.6.2.6
 IS INTENDED
 TO PROVIDE A MEANS TO MANUALLY ACTIVATE THE FIRE ALARM
 SYSTEM WHEN THE AUTOMATIC FIRE DETECTION SYSTEM OR
 WATERFLOW DEVICES
 ARE OUT OF SERVICE DUE TO MAINTENANCE OR TESTING, OR
 WHERE
 HUMAN DISCOVERY OF THE FIRE PRECEDES AUTOMATIC
 SPRINKLER SYSTEM
 OR AUTOMATIC DETECTION SYSTEM ACTIVATION. WHERE THE
 FIRE ALARM
 SYSTEM IS CONNECTED TO A MONITORING FACILITY, THE
 MANUAL FIRE
 ALARM BOX REQUIRED BY 9.6.2.6 SHOULD BE CONNECTED TO A
 SEPARATE
 CIRCUIT THAT IS NOT PLACED ?ON TEST? WHEN THE DETECTION
 OR SPRINKLER
 SYSTEM IS PLACED ON TEST. THE MANUAL FIRE ALARM BOX
 SHOULD BE
 LOCATED IN AN AREA THAT IS ACCESSIBLE TO OCCUPANTS OF
 THE BUILDING
 AND SHOULD NOT BE LOCKED.
  
  
 IN AN EFFORT TO REDUCE FALL ALARMS WHILE STILL
 COMPLYING WITH THE CODE PULL STATIONS CAN BE REMOVED
 THROUGHTOUT THE BUILDING AND PLACED IN A LOCATION
 ACCEPTABLE TO THE AHJ.
  
 COSIDER LOCATING ONE AT THE FRONT LOBBY; A 126, ONE AT
 THE EXIT DOOR OF ELEV LOBBY A132 AND ONE AT THE BEAUTY
 SALON; B124, MAIN EXIT DOOR ONLY.
  
  
  
 20) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 21) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-10-23 Cont ID  
Sent By lcrespo Date 2020-10-23 Time 13:07 Rev Time 0.00
Received By lcrespo Date 2020-10-16 Time 10:27 Sent To  
Notes
2020-10-23 13:07:4810/23/20 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By shill Date 2020-08-20 Time 16:16 Rev Time 0.00
Received By shill Date 2020-07-21 Time 10:08 Sent To  
Notes
2020-07-21 10:09:23GAS 1ST REVIEW COMMENTS:20011223
 1) SUBMIT WHICH OF THE APPLICABLE SIZING TABLES USED TO
 SIZE THE GAS SYSTEM AFTER THE PRESSURE REGULATORS OR
 PLACE A NOTE ON THE PLANS/DRAWINGS SPECIFYING WHICH
 SIZING TABLE(S) FROM THE GAS CODE OR OTHER STANDARD
 THAT WERE USED IN THE DESIGN OF THIS GAS SYSTEM. REFER
 TO THE 2017 FBC-FUEL GAS SECS. 401.4, 401.8, 402.3, AND
 TABLES 402.4 (1) THRU 402.4 (37)
 2) SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS.
 A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY
 AHEAD OF EACH MP REGULATOR. 2017 FBC-FUEL GAS SEC.409.4
 3) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 PRESSURE REGULATORS. REGULATORS INSTALLED ON THE
 EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION. 2014 FGC SEC.410.1
 4) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE
 APPLIANCE. COMPLY WITH 2017 FBC-FUEL GAS SEC. 402.4.1
 5) DISCOVERY ROOM B116 PROVIDE MAKE UP AIR. SUBMIT
 CALCULATIONS FOR COMBUSTION AIR PER THE 2017 FBC-FUEL
 GAS CODE SEC.304.1,
  
  
 TIM HUNT
 CITY OF WEST PALM BEACH ( CAP GOVERNMENT)
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2020-12-08 Cont ID  
Sent By lmarchan Date 2020-12-08 Time 08:36 Rev Time 0.00
Received By lmarchan Date 2020-12-01 Time 09:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2020-11-25 Cont ID  
Sent By ccarvaja Date 2020-11-25 Time 10:56 Rev Time 0.00
Received By ccarvaja Date 2020-11-04 Time 10:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2020-10-23 Cont ID  
Sent By lcrespo Date 2020-10-23 Time 13:09 Rev Time 0.00
Received By lcrespo Date 2020-10-08 Time 14:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-08-20 Cont ID  
Sent By shill Date 2020-08-20 Time 16:16 Rev Time 0.00
Received By shill Date 2020-08-11 Time 10:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-07-21 Cont ID  
Sent By lmarchan Date 2020-07-21 Time 14:12 Rev Time 0.00
Received By lmarchan Date 2020-07-16 Time 10:09 Sent To  
Notes
2020-07-21 10:13:06SENT FOR BUILDING AUDIT, PULLED FROM BUILDING REVIEW AS
 AN UPDATED AFFIDAVIT WAS NOT PROVIDED
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-07-16 Cont ID  
Sent By cpuell Date 2020-07-16 Time 11:48 Rev Time 0.00
Received By cpuell Date 2020-07-06 Time 15:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-06-25 Cont ID  
Sent By lmarchan Date 2020-06-25 Time 16:23 Rev Time 0.00
Received By lmarchan Date 2020-06-18 Time 11:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-18 Cont ID  
Sent By lmarchan Date 2020-06-18 Time 11:09 Rev Time 0.00
Received By lmarchan Date 2020-05-07 Time 10:51 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-12-07 Cont ID  
Sent By lmarchan Date 2020-12-07 Time 07:13 Rev Time 0.00
Received By lmarchan Date 2020-05-07 Time 14:12 Sent To  
Notes
2020-12-04 13:20:07RECEIPT - MU-2020-043977 - $121,150.26 - PAID
2020-05-07 14:12:575/7/20 NOTIFIED IMPACT TO REVIEW PER SKENNEDY. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-04-30 Cont ID  
Sent By shill Date 2020-04-30 Time 15:39 Rev Time 0.00
Received By shill Date 2020-04-30 Time 15:39 Sent To  
Notes
2020-04-30 15:40:25IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2020-12-04 Cont ID  
Sent By medwards Date 2020-12-04 Time 08:30 Rev Time 0.00
Received By medwards Date 2020-12-03 Time 08:14 Sent To  
Notes
2020-12-04 08:31:53ENGINEER OF RECORD PROVIDED INFORMATION AND TO ADDRESS
 THE RESTRICTION OF THE X VENT LOUVER BY SHOWING AN OVER
 ALL REDUCTION OF DRYER EXHAUST DUCT BY 10 FT. ME

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2020-11-17 Cont ID  
Sent By medwards Date 2020-11-17 Time 15:45 Rev Time 0.00
Received By medwards Date 2020-11-05 Time 17:00 Sent To  
Notes
2020-11-17 15:49:473RD REVIEW FBC-2017 MECHANICAL
 PERMIT-20011223
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE A LETTER FROM THE DRYER MANUFACTURER
 STATING THAT THE X VENT DRYER EXHAUST TERMINATION IS
 ALLOWED WITH THEIR DRYER. THE X VENT IS UNIQUE IN THE
 FACT THAT IT USES BOTH THE BACK-DRAFT DAMPER AND THE
 LOUVER. THE INSTALLATION MANUAL DOES NOT ADDRESS THIS
 KIND OF INSTALLATION. WITH THE X VENT SYSTEM THE BOX OF
 THE X VENT IS MOUNTED INTO THE EXTERIOR OF THE WALL AND
 THE LOUVER IS FLUSH TO THE EXTERIOR WALL. THE EXHAUST
 OF THE DRYER MUST TRAVEL THROUGH THE EXHAUST DUCT, OPEN
 THE BACK-DRAFT DAMPER AND TRAVEL THROUGH THE X VENT
 COVER (LOUVER) BEFORE IT IS EXHAUSTED TO THE OUTDOORS.
 BECAUSE THIS PRODUCT USES BOTH THE BACK-DRAFT DAMPER
 AND THE OUTER COVER OF THE BOX (LOUVER) INSTEAD OF
 EITHER THE BACK-DRAFT DAMPER OR THE LOUVER THE DRYER
 MANUFACTURER MUST ADDRESS THE ASSEMBLY. WE MUST HAVE AN
 APPROVAL LETTER FROM THE SPECIFIC DRYER MANUFACTURER
 FOR THE SPECIFIC DRYER USED IN THIS PROJECT. FBC M
 504.8.4.2
 YOU CAN SUBMIT THE DOCUMENTATION THAT WAS SUBMITTED TO
 THE PRIVATE PROVIDER AS PROOF THAT THE XVENT
 TERMINATION CAN BE USED WITH THE SPECIFIED DRYERS OR
 THE ENGINEER OF RECORD CAN SUBMIT CALCULATIONS
 ADDRESSING THE RESTRICTION OF BOTH THE BACKDRAFT DAMPER
 AND THE LOUVER AND HOW THIS WILL EFFECT THE DRYER DUCT
 LENGTHS.
  
  
 2) PREVIOUS CYCLE RESPONSE FROM DESIGNER STATED ? FBC
 M REQUIRED AMCA 550 RATINGS ONLY FOR LOUVERS.
 RESIDENTIAL BATHROOM AND DRYER EXHAUST VENTS DO NOT
 CLASSIFY AS LOUVERS THEREFORE THE REQUIREMENT SHOULD
 NOT APPLY.? AS THIS IS A COMMERCIAL BUILDING AND NOT
 EITHER A ONE OR TWO FAMILY DWELLING AND THE FACT THAT
 THE X VENT DOCUMENTATION SUBMITTED DOES CALL THE OUTER
 SECTION A LOUVER THE REVIEWERS COMMENT DOES APPLY AND
 MUST BE ADDRESSED. PLEASE PROVIDE SPECIFICATIONS THAT
 SHOW THE LOUVER SIZE MEETS FBC M 501.3.2. ?OPENINGS IN
 LOUVERS SHALL BE SIZED NOT LESS THAN ?? AND NOT LARGER
 THAN ??. PLEASE PROVIDE DOCUMENTATION IF THERE IS AN
 EXCEPTION FOR THE SIZES OF THE X VENT LOUVERS
  
 3) WE ARE ENFORCING THE 2017 FBC MECHANICAL, THE CODE
 SECTION MENTIONED IN THE RESPONSE LETTER (2018 IMC
 504.4.1) DOES NOT EXIST IN OUR CURRENT CODE BOOK.
 ACCORDING TO THE 2018 IMC COMMENTARY, 504.4.1 EXHAUST
 TERMINATION OUTLET AND PASSAGEWAY SIZE SHALL NOT BE
 DIMINISHED IN SIZE. PLEASE SHOW THAT THE LOUVERS MEET -
 FBC M 501.3.2
  
 4) SHEET M-2.1A; ALL TYPE I HOODS THAT PENETRATE A FIRE
 RATED ASSEMBLY MUST BE WRAPPED FROM THE HOOD TO THE
 POINT OF PENETRATION TO THE OUTLET TERMINAL. IN-LINE
 EXHAUST FANS NOT LOCATED OUTDOORS SHALL BE ENCLOSED AS
 REQUIRED FOR GREASE DUCTS. FBC M 506.3.11
  
 5) SHEET M-2.1A; AIR BALANCE REPORT: DESIGN PLANS FOR A
 FACILITY WITH A COMMERCIAL KITCHEN VENTILATION SYSTEM
 SHALL INCLUDE A SCHEDULE OR DIAGRAM INDICATING THE
 DESIGN OUTDOOR AIR BALANCE. THE DESIGN OUTDOOR AIR
 BALANCE SHALL INDICATE ALL EXHAUST AND REPLACEMENT AIR
 FOR THE FACILITY, PLUS THE NET EXFILTRATION IF
 APPLICABLE. THE TOTAL REPLACEMENT AIR AIRFLOW RATE
 SHALL EQUAL THE TOTAL EXHAUST AIRFLOW RATE PLUS THE NET
 EXFILTRATION. FBC M 508.1.2
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-10-16 Cont ID  
Sent By medwards Date 2020-10-16 Time 10:39 Rev Time 0.00
Received By medwards Date 2020-10-09 Time 11:43 Sent To  
Notes
2020-10-16 10:40:562ND REVIEW FBC-2017 MECHANICAL
 PERMIT-20011223
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE LOUVER OF THE XVENT WILL RESTRICT THE EXHAUST
 FLOW OF THE DRYER. PLEASE PROVIDE A LETTER FROM THE
 MANUFACTURE OF THE DRYER STATING THAT THE DRYER WILL IN
 FACT WORK WITH THE XVENT. FBC M 504.8.4.2
  
 2) PLEASE PROVIDE SPECIFICATIONS FOR THE XVENT EXHAUST
 TERMINATION SHOWING THEY COMPLY WITH AMCA STANDARD 550
 . FBC M 501.3.2
  
 3) PLEASE PROVIDE SPECIFICATIONS FOR THE XVENT EXHAUST
 TERMINATION INDICATING THE OPENINGS AT THE TERMINATION
 FACE MEETS THE SIZES REQUIRED IN FBC M 501.3.2 (MINIMUM
 ?? AND NOT LARGER THAN ??)
  
 4) PLEASE SHOW DRYER DUCT WORK AND LOCATION OF
 TERMINATION FOR THE LAUNDRY ROOM DRYERS. FBC M 504.9
  
 5) THE AIR BALANCE REPORT ON SHEET M-2.1A MUST MEET FBC
 M 508.1.2.
  
 6) SHEET M2.1A: THE FD?S ARE STILL BEING SHOWN IN THE
 GREASE DUCT FOR KEF-1 AND KEF-3 AND KEF-4. AS THESE ARE
 RATED WALLS PER SHEET LS-0.1 ALL GREASE DUCT MUST
 COMPLY WITH FBC M 506.3.11
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-08-17 Cont ID  
Sent By medwards Date 2020-08-17 Time 16:04 Rev Time 0.00
Received By medwards Date 2020-08-12 Time 14:09 Sent To  
Notes
2020-08-17 16:04:561ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20011223
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) PLEASE SHOW RATED WALLS ON ALL OF THE MECHANICAL
 SHEETS. FBC FS 107.2.1
  
 2) SHEET LS-0.0 THE ENERGY CALCULATIONS PRESENTED IN
 THIS PACKAGE IS FOR MULTI-FAMILY. PLEASE SPECIFY EACH
 OCCUPANCY BASED ON THE FBC CHAPTER 3.
  
 3) PLEASE PROVIDE ENERGY CALCULATIONS FOR EACH OF THE
 OCCUPANCY CLASSIFICATIONS. FBC EC 403
  
 4) IN THE R-2 OCCUPANCIES PLEASE SHOW WHICH METHOD IS
 USED FOR VENTILATION; NATURAL OR MECHANICAL. PROVIDE
 CALCULATIONS FOR THE ONE THAT IS USED. FBC M CHAPTER 4
  
 5) PLEASE REMOVE THE NOTE AT THE BOTTOM LEFT OF THE
 MECHANICAL SHEETS AS THESE SHOULD BE CONSTRUCTION
 DOCUMENTS NOT FOR INITIAL PERMIT REVIEW. FBC FS 107.2.1
  
 6) PLEASE PROVIDE DUCT GRILL SIZES FOR ALL SHEETS. FBC
 FS 107.2.1
  
 7) PLEASE PROVIDE RETURN AIR TRANSFER SIZES IN ALL
 LIVING QUARTERS. FBC FS 107.2.1
  
 8) SHEET M-6.4: VENTILATION EQUIPMENT SCHEDULE (TOP
 CHART) SHOWS 6 NOTES. NOTE 6 HAS BEEN LEFT BLANK.
 PLEASE SHOW THE NOTE OR IF THERE IS NO NOTE REMOVE THE
 NUMBER 6. FBC FS 107.2.1
  
  
 9) SHEET M-6.5 SHOWS OUTSIDE AIR CALCULATIONS FOR
 (RESIDENTIAL) ENERGY CALCULATIONS INDICATES 0 CFM
 OUTSIDE AIR FOR (SENIOR UNITS) PLEASE BE CONSISTENT ON
 BOTH. FBC FS 107.2.1
  
 10) SHEET M-6.4 DESIGNATES OUTSIDE AIR CALCULATIONS FOR
 THIS BUILDING. PLEASE REFLECT THESE CALCULATIONS ON THE
 ENERGY CALCULATIONS SUBMITTED, SEVERAL AREAS INDICATE 0
 CFM OUTSIDE AIR. FBC M 401.
  
 11) PLEASE SHOW HOW YOU ARE PROVIDING OUTDOOR AIR FOR
 ALL LOUNGES. FBC M 401
  
  
 12) PLEASE PROVIDE CALCULATIONS AND WAY NATURAL
 VENTILATION IS PROVIDED ON ALL AREAS THAT ARE USING
 NATURAL VENTILATION. FBC M 402
  
  
 13) SHEET M-5.1 DRAWING 1- PLEASE PROVIDE THE TYPE OF
 MATERIAL USED FOR THE A/C CONDENSATE DRAIN PIPE IN THIS
 PLENUM AREA. FBC M 602.2.1
  
  
 14) SHEET M-5.1 DRAWING 8- PLEASE PROVE THE SIGNED AND
 SEALED DRAWINGS FOR THE ELEVATOR SHAFT RELIEF LOUVER.
 FBC FS 107.2.1
  
 15) SHEET M-5.1 DRAWING 3- PLEASE SHOW HOW THIS X-VENT
 FOR A DRYER DUCT MEETS- FBC M 504.4 FOR NO SCREENS AT
 DUCT TERMINATION AND THE WAY THIS APPEARS TO OPEN FROM
 THE MIDDLE, HOW THE BACKDRAFT DAMPER WILL NOT GATHER
 LINT.
  
  
 16) SHEET M-5.1: DRAWING (2) INDICATES A FRESH AIR DUCT
 RAN INTO THE MECHANICAL CLOSETS OF THE APARTMENTS.
 PLEASE SHOW THESE, THE CEILING ACCESS PANEL AND THE
 OUTDOOR AIR TERMINATION ON THE EXTERIOR OF THE
 BUILDING, ON ALL THE UNIT DRAWINGS THAT ARE GOING TO
 HAVE THESE INSTALLED. FBC FS 107.2.1
  
 17) PROVIDE A COPY OF THE INSTALLATION INSTRUCTIONS FOR
 THE MAKE AND MODEL OF THE DRYER FOR EVERY RESIDENTIAL
 DRYER WITH AN EXHAUST DUCT LENGTH OVER 35?. FBC M
 504.8.4.2
  
  
 18) WHERE THE DRYER EXHAUST DUCT EQUIVALENT LENGTH
 EXCEEDS 35? THE EQUIVALENT LENGTH OF THE DUCT SHALL BE
 IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR
 TAG SHALL BE LOCATED WITHIN 6? OF THE EXHAUST DUCT
 CONNECTION. FBC M 504.8.5
  
 19) PLEASE SHOW KITCHEN VENTILATION FOR ALL DWELLING
 UNITS THAT ARE PROVIDED WITH A KITCHEN. FBC M TABLE
 403.3.1.1
  
  
 20) SHEET M-4.3 PLEASE SHOW THE RETURN PATH TO THE
 AHU?S THROUGH THE DOOR OF THE MECHANICAL CLOSETS. FBC M
 601.6
  
 21) SHEET M-4.3 UNIT IL-A4- PLEASE SHOW THE RETURN AIR
 PATH FROM MASTER BEDROOM. FBC M 601.6
  
 22) SHEET M-4.3 PLEASE PROVIDE THE DISTANCE FROM THE
 COOKING APPLIANCE AND THE RETURN AIR OPENINGS. FBC M
 601.5
  
  
 23) M-4. SHEETS. PLEASE SHOW HOW YOU ARE PROVIDING
 MAKE-UP AIR FOR THE DRYER. FBC M 504.6
  
 24) M-4. SHEETS- PLEASE SHOW THE ENTIRE DRYER DUCT IN
 THE APARTMENTS GOING FROM DRYER TO TERMINATION, THEY
 APPEAR TO STOP AT THE BATH EXHAUST DUCT. FBC FS 107.2.1
  
  
 25) ON THE UNIT DRAWINGS THERE ARE UNITS THAT HAVE A
 TOILET ROOM ENCLOSED IN THE BATHROOM, PLEASE PROVIDE
 BATHROOM EXHAUST IN THE BATHROOM ALSO. FBC M BATHROOM
 DEFINITION; FBC M TABLE 4.3.3.1.1
  
 26) SHEET M-4.SHEETS- PLEASE SHOW THAT THE EXHAUST
 TERMINATIONS ARE A MINIMUM OF 3? FROM OPERABLE OPENINGS
 INTO THE UNIT. FBC M 501.3.1 (3)
  
 27) SHEET M-4.7: UNIT IL-D1- PLEASE SHOW THE RETURN
 PATH FOR THE DEN. FBC FS 107.2.1
  
 28) SHEET M-2.5B: PLEASE REMOVE ALL CLOUDS FROM SHEETS
 AS THIS IS A 1ST CYCLE REVIEW. FBC FS 107.2.1
  
 29) SHEET M-2.5B: PLEASE SHOW HOW CORRIDOR AT W BATH
 B505 AND M BATH B504 IS VENTILATED. FBC M TABLE
 403.3.1.1
  
 30) SHEET M-2.5B : PLEASE SHOW AND IDENTIFY THE EXHAUST
 FANS IN THE MENS AND WOMENS BATHROOMS. FBC FS 107.2.1
  
  
 31) SHEET M-7.1 VENTILATION RISER DIAGRAM CFM?S DO NOT
 MATCH BLDG. PLAN LEVEL SHEETS. EXAMPLES ARE- PLEASE
 CHECK THE CFM?S OF THE ACS AT EACH FLOOR. ACS-2 SHOWS
 650 CFM PER FLOOR. SHEETS M-2.6A AND M-2.6B SHOWS ONLY
 400 CFM PER FLOOR. ACS-3 SHOWS 550 FOR EACH FLOOR,
 BLDG.. PLAN LEVEL SHEETS SHOW 370 CFM. FBC FS 1.7.2.1
  
 32) IDENTIFY EACH MAU RISER ON EACH FLOOR AT THE SHAFT
 WHERE IT ENTERS THE FLOOR. FBC FS 107.2.1
  
 33) SHEET M-2.3.1: THE STORAGE ROOM IS ACCESSED THROUGH
 THE PARKING GARAGE. PLEASE PROVIDE A FD FOR THE DUCT
 WORK PENETRATING THE RATED WALL AT CORRIDOR AND STORAGE
 ROOM. FBC FS 107.2.1
  
 34) PLEASE LABEL WASHERS AND DRYERS IN EACH LAUNDRY
 AREA TO PROVIDE A COUNT OF EACH. FBC FS 107.2.1
  
 35) PROVIDE CLOTHES DRYER SPECS AND DUCT SIZES FOR
 EACH, ALONG WITH DEVELOPED LENGTH AND TERMINATION
 LOCATION FOR ALL LAUNDRY ROOMS. FBC FS 107.2.1
  
 36) PLEASE PROVIDE COMBUSTION AIR CALCULATIONS FOR ALL
 DRYERS IN THE LAUNDRY ROOMS. FBC FS 107.2.1
  
 37) IN ALL ROOMS WITH FCU?S PLEASE PROVIDE OUTDOOR AIR
 CFM?S BEING SUPPLIED TO EACH UNIT ON THE DRAWINGS. FBC
 FS 107.2.1
  
 38) PLEASE PROVIDE A DETAIL DRAWING SHOWING THE KEF
 TERMINATIONS ON THE EXTERIOR OF THE BUILDING. FBC M
 506.3.13
  
 39) PLEASE SHOW DISTANCE FROM PROPERTY LINES FOR ALL
 HOOD TERMINATIONS. FBC M 506.3.13.3
  
 40) KITCHEN HOODS WILL REQUIRE A SEPARATE PERMIT AND
 REVIEW. FBC FS 107.2.1
  
 41) SHEET M-2.2A: HOW ARE YOU PROVIDING MAKE-UP AIR FOR
 THE HOODS? FBC FS M 508.1
  
 42) PLEASE PROVIDE AN AIR BALANCE REPORT FOR THIS
 STRUCTURE. FBC M 508.1.2
  
 43) PLEASE PROVIDE KITCHEN EQUIPMENT INFORMATION AND
 LOCATIONS. FBC FS 107.2.1
  
 44) SHEET M-2.1A: PLEASE SHOW BATH EXHAUST FAN AND DUCT
 WORK TO TERMINATION FOR BATHROOM BEHIND PREPARATION
 KITCHEN. FBC FS 107.2.1
  
 45) PLEASE EXPLAIN WHAT TEF-A IS EXHAUSTING AND
 IDENTIFY THE ROOM IT IS LOCATED IN. FBC FS 107.2.1
  
 46) PLEASE SHOW THE RATED DAMPER AT THE RATED WALL
 DIVIDING THE SMOKE COMPARTMENTS. FBC FS 107.2.1
  
 47) SHEET M-2.1A PROVIDE SPECS FOR THE HORIZONTAL MAU.
 NOTE 11 STATES TO LOOK AT THE ROOF PLANS FOR LOCATION
 OF THE REMOTE AIR COOLED CONDENSING UNITS. PLEASE
 IDENTIFY EACH FOR THE MAU IT IS IDENTIFIED WITH. FBC FS
 107.2.1
  
 48) IT APPEARS THAT YOU HAVE FD?S IN GREASE DUCT AT
 RATED WALL PENETRATIONS, PLEASE REMOVE ALL FD?S IN THE
 GREASE DUCT AND SHOW HOW YOU WILL PROTECT THE
 PENETRATIONS AS FD?S ARE NOT ALLOWED IN GREASE DUCTS.
 FBC M 506.3.11
  
 49) THERE WILL BE A SEPARATE PERMIT AND REVIEW FOR ALL
 OF THE REFRIGERATION SYSTEMS. FBC FS 107.2.1
  
 50) PLEASE SHOW HOW KEF-1 AND KEF-3 COMPLY WITH FBC M
 506.5.1.2 IN-LINE FAN LOCATION.
  
 51) PLEASE SHOW THE CLEANOUTS FOR THE INLINE FANS FOR
 KEF-1 AND KEF-3. FBC M 506.3.8.2
  
 52) PLEASE SHOW GREASE DUCT CLEANOUT LOCATIONS. FBC M
 506.3.8
  
 53) PLEASE PROVIDE SPECS FOR COMMERCIAL LAUNDRY
 EQUIPMENT. FBC FS 107.2.1
  
 54) PLEASE IDENTIFY LAUNDRY EQUIPMENT ON PLANS. FBC FS
 107.2.1
  
 55) PLEASE PROVIDE COMBUSTION AIR CALCULATIONS FOR
 COMMERCIAL DRYERS AND O.A. LOUVER. FBC FG CHAPTER 4.
  
 56) SHEET M-2.A THE WALLS OF THE LAUNDRY ROOM ARE
 RATED, PLEASE SHOW HOW ALL THE DUCT PENETRATIONS MEET
 FBC M 607.5.3
  
 57) IN THE GRAND FOYER THERE IS A LABEL BAR/GRILL, IS
 THERE ANY COOKING BEING DONE IN THIS AREA? FBC FS
 107.2.1
  
 58) PLEASE PROVIDE SPEC SHEETS FOR GENERATOR. FBC FS
 107.2.1
  
 59) THE GENERATOR MUST BE UNDER A SEPARATE PERMIT AND
 REVIEW. FBC FS 107.2.1
  
 60) PLEASE PROVIDE A DETAIL DRAWING OF THE GENERATOR
 ROOM ALONG WITH VENTILATION CALCULATIONS TO VERIFY
 LOUVER SIZES. FBC FS 107.2.1
  
 61) PLEASE SHOW THE GENERATOR EXHAUST PIPING AND
 TERMINATION. FBC FS 107.2.1
  
 62) PLEASE EXPLAIN THE INTENT OF EF-4 AND THE 14?X14?
 DUCT WORK IN THE GENERATOR ROOM. FBC FS 107.2.1
  
 63) PLEASE PROVIDE SPECS FOR ALL EQUIPMENT IN THE
 BOILER ROOM. FBC FS 107.2.1
  
 64) SHEET M-2.1B: NOTE (5) STATES THIS LOUVER IS AN OUT
 DOOR AIR TO AHU/ FCU RETURN. THIS LOUVER IS LOCATED
 INSIDE THE ENTRANCE OF THE PARKING GARAGE. PLEASE SHOW
 THIS LOUVER AT THE EXTERIOR OF THE BUILDING. FBC FS
 107.2.1
  
 65) SHEET M-2.1B: O/A LOUVER FOR AHU-OFF IS LOCATED IN
 THE PARKING GARAGE, THIS CANNOT BE LOCATED IN THIS
 AREA. PLEASE MOVE THE O/A LOUVER TO THE EXTERIOR OF THE
 BUILDING. FBC FS 107.2.1
  
 66) PLEASE PROVIDE DETAILS FOR THE BEAUTY SALON, PLEASE
 SHOW IT MEETS FBC M TABLE 403.3.1.1 FOR VENTILATION AND
 FOOTNOTES (B & H).
  
 67) SHEETS M2.1A AND M2.1B: ACCORDING TO SHEET LS-0.1
 THERE ARE SEVERAL RATED WALLS ON THIS FLOOR. PLEASE
 SHOW THE REQUIRED FD FOR EACH DUCT PENETRATION. FBC M
 607.5.3
  
 68) THERE ARE SEVERAL (MEP CLOSETS) ON THIS 1ST FLOOR.
 ACCORDING TO SHEET LS-0.1 THESE CLOSETS ARE 1 HR. RATED
 FIRE PARTITIONS, PLEASE SHOW FD IN EACH PENETRATION OF
 THESE RATED WALLS. FBC M 607.5.3
  
 69) PLEASE PROVIDE DETAIL DRAWINGS AND CALCULATIONS
 THAT SHOW THE PARKING GARAGE IS AN OPEN GARAGE. FBC FS
 107.3.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-10-23 Cont ID  
Sent By lacrespo Date 2020-10-23 Time 13:08 Rev Time 0.00
Received By lcrespo Date 2020-10-16 Time 10:27 Sent To  
Notes
2020-10-23 13:08:4610/23/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By thunt Date 2020-08-20 Time 15:27 Rev Time 0.00
Received By shill Date 2020-08-20 Time 15:27 Sent To  
Notes
2020-07-21 10:08:11PLUMBING 1ST REVIEW COMMENTS:20011223
 1) SHEET 5.10 KITCHEN WATER ISOMETRIC MISSING DOWN FEED
 SHUT OFF VALVE. FBC-PLB 606.1
 2) SHEET P6.1 SHOW A/C COND DISCHARGING INTO THE STORM.
 PER CITY OF WEST PALM BEACH CITY ORD.
 3) SHEET 6.1 POOL MAKE UP WATER PER W.P.B CROSS
 CONNECTION MANUAL MUST BE RPZ TYPE, LEAD FREE, AND
 INSTALLED ONLY BY LICENSED PLUMBING CONTRACTOR.
 4) SHEET 6.1 BOOSTER PUMP WATER DETAIL SHOWS THE
 EXPANSION VALVE AS TYPE WATTS 174A SET @ 100 PSI FOR
 THERMO EXPANSION CONTROL. THIS DEVICE IS NOT APPROVED
 AS A THERMO EXPANSION DEVISE FBC-PLB 607.3 AND MUST BE
 SET AT A MAX PRESSURE OF 80 PSI. FBC-PLB 604.8
 5) SHEET 6.1 POOL BACKWASH IS NOT PERMITTED TO
 DISCHARGE INTO THE SANITARY SYSTEM PER W.P.B CITY ORD.
 6) SHEET 6.2 WATER HEATER PIPING DETAIL PLEASE SHOW
 PIPE SIZE. FBC 107.2.1
 7) COMMENT REMOVED
 8) BASE ON YOUR DESCRIPTION OF THIS PROJECT IT WOULD
 SEEM TO ME THAT THIS WOULD BE A LONG TERM CARE FACILITY
 WHICH REQUIRES 50% OF THE OCCUPIED ROOMS TO MEET
 FLORIDA ACCESSIBILITY. FBC-ACC 223.4
 9) MALE AND FEMALE RESTROOMS A123, A125 MUST HAVE 1 OF
 EACH COMMON SINK MEET FLORIDA ACCESSIBILITY. FBC-ACC
 212.2. PLEASE SHOW THE REQUIRED CLEAR FLOOR SPACE.
 10) SHEET A2.1B BEAUTY SALON TEA/COFFEE SINK PLEASE
 SHOW THE REQUIRED CLEAR FLOOR SPACE DETAIL. FBC-ACC
 212.2.
 11) SHEET A2.1B PANTRY B107 PLEASE SHOW THE REQUIRED
 CLEAR FLOOR SPACE DETAIL. FBC-ACC 212.2.
 12) PLEASE SHOW ALL ROOM DIMENSIONS THAT CONTAIN
 PLUMBING FIXTURES. WITHOUT I AM UNABLE TO VERIFY
 FLORIDA ACCESSIBILITY CAN BE ACHIEVED. FBC 107.3.5
 13) ALL ACCESSIBLE ROOMS SHOW ROLL IN SHOWERS. ROLL IN
 SHOWERS ARE NOT PERMITTED UNTIL THE MIN TUBS/ TRANSFER
 SHOWERS HAVE BEEN PROVIDED PER TABLE FBC-ACC 224.2.
 14) PLEASE CALL OUT TYPE A OR B SPEC FOR THE BATHING
 UNITS. FHA 7.34. UNIT WITH 2 BATHING ROOM YOU ONLY SHOW
 1 PLEASE LIST THEM AS B SPEC. FBC 107.3.5
 15) SHEET A2.6A UNITS WITH DOUBLE SINK HAVE BOTH A TUB
 AND SHOWER BUT NOT WAY TO ACCESS THEM. PLEASE CLARIFY.
 FBC 107.2.1
 16) SHEET A2.4 YOU CALL OUT 154 TOTAL ROOM BUT ONLY 3
 ADA ROOMS. PLEASE CLARIFY. FBC 107.2.1
 17) SHEET A 2.2A TOILET ROOM #A209 PLEASE SHOW THE
 CLEAR FLOOR SPACE AND TURNING SPACE. FBC-ACC 603.2
 18) SHEET A2.3 AND A307 APPEAR TO BE COMMON LAUNDRY
 ROOMS. PLEASE PROVIDE THE REQUIRED CLEAR FLOOR SPACE
 AND REACH RANGE DETAIL. FBC-ACC 611.
 19) SHEET A4.10 SHOWS A VERTICAL GRAB BAR. ALL GRAB
 BARS SHALL BE INSTALLED IN THE HORIZONTAL POSITION.
 FBC-ACC 609.4
 20) SHEET A4.10 - A4.13 PROVIDE GRAB BAR DETAIL FOR
 BOTH THE REAR AND SIDE GRAB BAR IN DETAIL # 3 AND 4.
 FBC-ACC 604.5.1, 605.5.2
 21) SHEET A4.10 - A4.13 SHOW MIRROR MOUNTING TO THE
 BOTTOM OF THE REFLECTIVE SURFACE. FBC-ACC 603.3.
 22) SHEET A4.11 SHOW THE SHOWER VALVE BEING INSTALLED
 MAX 48? OFF FINISHED FLOOR. FBC-ACC 608.5.
 23) SHEETS A4.14 - A4.17, A10.1, A10.2 , A10.4 SHOW THE
 TOILET TO BE INSTALLED A MIN OF 18?. THIS WOULD BE
 INCORRECT FOR BOTH FHA AND FLORIDA ACCESSIBILITY. FHA
 DESIGN MANUAL REQUIRED 18? AS ABSOLUTE MEASUREMENT (FHA
 6.5) AND FLORIDA ACCESSIBILITY THIS WOULD BE THE MAX.
 FBC-ACC 604.2
 24) SHEETS A5.4 DETAIL # 1 AND 3 AND A5.6 SHOW THE GRAB
 BARS AT BEING MOUNTED @ 36 TO THE CENTER. MAX ALLOWED
 IS 36? TO THE TOP OF THE GRIPPING SURFACE. FBC-ACC
 609.4
 25) SHEET A5.4 LOBBY REST ROOMS DO NOT APPEAR TO ME
 POTTY PARITY. PLEASE CLARIFY. FBC-PLB 403.1.3.
 26) SEVERAL SHEETS EX. A103 HEADING IS LISTED AS
 ACCESSIBILITY UNIT BUT SHOW FAIR HOUSING. PLEASE
 CLARIFY FBC 107.2.1.
 27) SHEET A.103 DETAIL # IL-A2 IS SHOWING THE TOILET
 ADJACENT TO THE SHOWER WHICH PER FHA 7.44 IS NOT
 PERMITTED.
 28) SHEET A10.4 SHOWS WASHING MACHINE AS ACCESSIBLE
 UNIT BUT APPEAR TO BE AN FHA UNIT. PLEASE CLARIFY. FBC
 107.2.1
 29) SHEET A10.5 UNIT IL-C3 PLEASE PROVIDE THE CLEAR
 FLOOR SPACE.
 30) SHEET A10.6 FOR ALL FHA UNITS WITH THE SHOWER
 ACROSS FROM THE TOILETS PLEASE SHOW THE 48? X 56? CLEAR
 FLOOR SPACE IS BEING ARCHIVED. FHA 7.44
 31) PLEASE CLARIFY WHICH DESIGN SPEC YOUR DESIGN IS
 BASED ON. IT APPEARS TO BE (B) BUT SHEET A10.7 UNIT
 IL-C8 AND ALL UNITS SHOWN ON SHEET A10.8 ARE NOT LABEL
 AT ALL. FBC 107.2.1
 32) SHEET P2A THE MEN'S TOILET COMPARTMENT TOILET MUST
 BE DIAGONAL OF THE DOOR. FBC-ACC 604.8.1.7.
 33)COMMENT REMOVED
 34) SHEET P2.2A AND A2.3A IS MISSING THE FLOOR DRAIN IN
 THE LAUNDRY ROOM. FBC-PLB 412.4.
 35) SHEET P2.2A ROOM 214,215 SANITARY BRANCH THE COMBO
 IS FACING THE WRONG WAY. FBC-PLB 706.3
 36) SKY LOUNGE KITCHEN HAS 2 FIXTURES BEYOND THE VENT.
 MUST ADD VENT BETWEEN F.S.K AND F.D.
 37) SHEET P4.3 UNIT 215 COMBO FITTING FACING WRONG
 DIRECTION. FBC-PLB 412.4.
 38) SHEETS A4.1 THRU A4.8 APPEAR TO SHOW ADA ROLL IN
 SHOWERS WITH SEAT. THE CONTROL WALL IS SHOWN AS ACROSS
 FROM THE SEAT WHEN IT SHOULD BE WITH IN 27? OF THE SEAT
 ON THE BACK WALL PER FBC-ACC 608.5.2.
 39) PLEASE SHOW THE PIPE SIZE ON THE PLUMBING ISOMETRIC
 SHEET P5.1. FBC 107.3.5
 40) SHEET P5.5 STACK # 5 SHOW THE KITCHEN DISCHARGING
 INTO THE BATHROOM GROUP WET VENT. NO FIXTURES OTHER
 THAN ANOTHER BATHROOM GROUP MAY DISCHARGE IN THIS WET
 VENT. FBC-PLB 912.2.1
  
 TIM HUNT
 CITY OF WEST PALM BEACH ( CAP GOVERNMENT)
 [email protected]
  
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 5 Status P Date 2020-12-07 Cont ID  
Sent By rgathrig Date 2020-12-07 Time 18:49 Rev Time 0.00
Received By rgathrig Date 2020-12-07 Time 18:47 Sent To  
Notes
2020-12-07 18:48:47WITH FORTHCOMING

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status F Date 2020-11-17 Cont ID  
Sent By shill Date 2020-11-17 Time 16:51 Rev Time 0.00
Received By shill Date 2020-11-17 Time 16:51 Sent To  
Notes
2020-11-17 16:51:38PRIVATE PROVIDER DOCUMENTS:
  
  
 NOTICE TO BUILDING OFFICIAL OF USE OF PRIVATE PROVIDER,
 PLAN REVIEW AND INSPECTIONS DOCUMENTS ARE (OK)
  
 PRIVATE PROVIDER PLAN COMPLIANCE AFFIDAVITS CANNOT BE
 APPROVED AT THIS TIME UNTIL THE COMMENTS FROM THE PLAN
 REVIEW AUDITS ARE ADDRESSED.
  
 WHEN THE NEW PAGES ARE SUBMITTED TO ADDRESS THE PLAN
 REVIEW AUDIT COMMENTS, PLEASE HAVE THE PRIVATE PROVIDER
 CODE CODE COMPLIANCE AFFIDAVITS ADDRESS ALL THE PAGE
 NUMBERS REVIEWED, DESIGNER(S) OF RECORD, AND THE DATES
 OF THE PAGES.
  
 THANK YOU
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL
 561-805-6679

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status F Date 2020-10-16 Cont ID  
Sent By shill Date 2020-10-16 Time   Rev Time 0.00
Received By shill Date 2020-10-16 Time   Sent To  
Notes
2020-10-16 19:01:15PRIVATE PROVIDER DOCUMENTS:
  
  
 NOTICE TO BUILDING OFFICIAL OF USE OF PRIVATE PROVIDER,
 PLAN REVIEW AND INSPECTIONS DOCUMENTS ARE (OK)
  
 PRIVATE PROVIDER PLAN COMPLIANCE AFFIDAVITS CANNOT BE
 APPROVED AT THIS TIME UNTIL THE COMMENTS FROM THE PLAN
 REVIEW AUDITS ARE ADDRESSED.
  
 WHEN THE NEW PAGES ARE SUBMITTED TO ADDRESS THE PLAN
 REVIEW AUDIT COMMENTS, PLEASE HAVE THE PRIVATE PROVIDER
 CODE CODE COMPLIANCE AFFIDAVITS ADDRESS ALL THE PAGE
 NUMBERS REVIEWED, DESIGNER(S) OF RECORD, AND THE DATES
 OF THE PAGES.
  
 THANK YOU
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL
 561-805-6679

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2020-08-21 Cont ID  
Sent By rgathrig Date 2020-08-21 Time 15:48 Rev Time 0.00
Received By rgathrig Date 2020-08-21 Time 15:41 Sent To  
Notes
2020-08-21 15:48:21PRIVATE PROVIDER DOCUMENTS:
  
  
 NOTICE TO BUILDING OFFICIAL OF USE OF PRIVATE PROVIDER,
 PLAN REVIEW AND INSPECTIONS DOCUMENTS ARE (OK)
  
 PRIVATE PROVIDER PLAN COMPLIANCE AFFIDAVITS CANNOT BE
 APPROVED AT THIS TIME UNTIL THE COMMENTS FROM THE PLAN
 REVIEW AUDITS ARE ADDRESSED.
  
 WHEN THE NEW PAGES ARE SUBMITTED TO ADDRESS THE PLAN
 REVIEW AUDIT COMMENTS, PLEASE HAVE THE PRIVATE PROVIDER
 CODE CODE COMPLIANCE AFFIDAVITS ADDRESS ALL THE PAGE
 NUMBERS REVIEWED, DESIGNER(S) OF RECORD, AND THE DATES
 OF THE PAGES.
  
 THANK YOU
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL
 561-805-6679

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2020-07-21 Cont ID  
Sent By shill Date 2020-07-21 Time 13:59 Rev Time 0.00
Received By shill Date 2020-07-21 Time 13:51 Sent To  
Notes
2020-07-21 13:54:08PRIVATE PROVIDER DOCUMENTS:
  
 4/30/20 - NOTICE TO BUILDING OFFICIAL OF USE OF PRIVATE
 PROVIDER, PLAN REVIEW AND INSPECTIONS (OK)
  
 4/30/20 - PRIVATE PROVIDER PLAN COMPLIANCE AFFIDAVIT IS
 DATED 4/24/20. IT LISTS PAGE NUMBERS BUT DOES NOT
 PROVIDE THE DATE THE PLAN WAS SIGNED SO IT IS NOT
 POSSIBLE TO KNOW WHICH VERSION OF THE PLAN THE PRIVATE
 PROVIDER REVIEWED. HOWEVER, SINCE THE AFFIDAVIT IS
 DATED PRIOR TO PLAN REVISIONS, IT APPEARS THAT THE
 AFFIDAVIT IS NOT FOR THE PLANS SUBMITTED. NOTE THAT IT
 APPEARS THAT ALL PAGES CHANGED.
  
 FOR INSTANCE, SHEET 041 LS-0.1 LIFE SAFETY LEVEL 1 HAS
 HAD TWO REVISIONS AFTER PERMIT SET 4/14/20 DATED
 5/22/20 AND 6/29/20.
  
 PRIVATE PROVIDER REVIEW AND AFFIDAVIT IS REQUIRED PRIOR
 TO BUILDING DIVISION AUDIT.
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2021-12-09 Cont ID  
Sent By rmcphers Date 2021-12-09 Time 11:18 Rev Time 0.00
Received By rmcphers Date 2021-12-09 Time 11:18 Sent To  
Notes
2021-12-09 11:19:07ROOFING TO BE DEFERRED

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-12-03 Cont ID  
Sent By medwards Date 2020-12-03 Time 08:14 Rev Time 0.00
Received By medwards Date 2020-12-03 Time 08:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-11-04 Cont ID  
Sent By shill Date 2020-11-04 Time 15:03 Rev Time 0.00
Received By shill Date 2020-11-04 Time 15:03 Sent To  
Notes
***NONE***

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status P Date 2020-11-17 Cont ID  
Sent By rmcphers Date 2020-11-17 Time 07:56 Rev Time 0.00
Received By rmcphers Date 2020-11-17 Time 07:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2020-11-25 Cont ID  
Sent By elevesqu Date 2020-11-25 Time 09:51 Rev Time 0.00
Received By elevesqu Date 2020-11-25 Time 09:51 Sent To  
Notes
2020-11-25 09:52:06PROVISOS:
  
 1. PLEASE COORDINATE WITH ENG. DEPT. TO UPDATE THE
 TRUNCATED DOME AT THE DIXIE/DATURA CROSSING TO SPREAD
 THE ENTIRE WIDTH OF BOTH CROSSWALKS (EAST/WEST AND
 NORTH/SOUTH) ? SAME TYPE OF TRUNCATED DOME AS THE
 BROADSTONE PROJECT INSTALLED DIRECTLY SOUTH. THE
 CURRENT ALIGNMENT PUTS PEDESTRIANS INTO THE CENTER OF
 THE INTERSECTION
 2. UPDATE CIVIL PLANS (PERMIT REVISION) TO INCLUDE
 MODIFIED ENTRIES ALONG NORTHWEST SECTION OF ALLEY
 3. PATHWAY SHALL BE ADDED FROM WESTERN ROW OF PAVERS IN
 PUBLIC PLAZA CONNECTING TO DATURA STREET SIDEWALK (AT
 LEAST 36?? WIDE AND 2% MAX SLOPE FOR ADA ACCESSIBILITY
 )
 4. THE CONCRETE CANOPY SHALL BE RELOCATED TO AN
 APPROPRIATE LOCATION PER HISTORIC PRESERVATION DIVISION
 APPROVAL. THE MAINTENANCE OF THE CANOPY SHALL BE
 DETERMINED BY DEVELOPER AND PROPERTY OWNER OF SITE
 WHERE CANOPY IS RELOCATED.
 5. REMOVAL OF EXISTING PALM TRAN BUS SHELTER SHALL BE
 COORDINATED WITH PALM TRAN. SHALL ONLY BE REMOVED WHEN
 NEW BUS SHELTER HAS BEEN MODIFIED AND OPENED FOR
 SERVICE.
 6. DEVELOPER SHALL REMOVE ALL OVERHEAD WIRES ON
 PROPERTY INCLUDING THOSE ALONG DIXIE HIGHWAY
 7. JUSTIFICATION STATEMENT SHALL BE PROVIDED BY
 DEVELOPER OUTLINING PLAN FOR CLOSURE OF EXISTING
 PARKING LOT
 8. STAFF RECOMMENDS THE UTILIZATION OF SCAFFOLDING TO
 KEEP ROW SIDEWALKS OPEN TO PUBLIC
 9. ALL FDC SHALL BE WALL MOUNTED AND PAINTED TO MATCH
 ADJACENT BUILDING FA?ADE (SUBJECT TO FIRE DEPT.
 APPROVAL). ALL ABOVE GROUND UTILITIES SHALL BE PAINTED
 TO MATCH ADJACENT FA?ADE OR LANDSCAPE BED AND SHALL BE
 SCREENED BY LANDSCAPE TO BEST EXTENT POSSIBLE
 10. ALL SIGNAGE WITHIN THE ROW THAT IS REMOVED DURING
 CONSTRUCTION SHALL BE REPLACED
 11. BACKFLOW PREVENTER SHALL BE INSTALLED IN WAY THAT
 THERE IS SUFFICIENT ROOM IN FRONT (DATURA SIDE) TO
 PROVIDE SCREENING
 12. PER EMAIL CONVERSATION WITH TRACY WARD ON DECEMBER
 27, 2019, THE DESIGN OF THE EXFILTRATION TRENCH THROUGH
 THE PUBLIC PLAZA SHALL NOT INCLUDE EXFILTRATION UNDER
 PROPOSED TREES.
 13. A MAINTENANCE AGREEMENT SHALL BE RECORDED BETWEEN
 DEVELOPER AND CITY FOR MAINTENANCE OF THE ROW WITHIN 90
 DAYS OF TCO
 14. ALL CONDITIONS FROM SITE PLAN APPROVAL THAT HAVE
 NOT BEEN SATISFIED STILL APPLY
 15. THE FOLLOWING ITEMS REQUIRE SEPARATE PERMITS:
 A. LANDSCAPE
 B. TREE REMOVAL
 C. IRRIGATION
 D. BUS SHELTER BACKING
 E. SIGNAGE
 F. PHOTOMETRICS
 16. MINOR AMENDMENT FOR AS-BUILTS SHALL BE SUBMITTED
 PRIOR TO CO (FORMAL APPLICATION TO P&Z)
 A. UPDATE FAR IN SITE PLAN DATA
 B. ALL UPDATED PLANS- CIVIL, LANDSCAPE, ARCHITECTURAL,
 ETC.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2020-07-09 Cont ID  
Sent By elevesqu Date 2020-07-09 Time 10:39 Rev Time 0.00
Received By elevesqu Date 2020-07-09 Time 10:39 Sent To  
Notes
2020-07-09 10:40:26PROVISOS:
  
 1. PLEASE COORDINATE WITH ENG. DEPT. TO UPDATE THE
 TRUNCATED DOME AT THE DIXIE/DATURA CROSSING TO SPREAD
 THE ENTIRE WIDTH OF BOTH CROSSWALKS (EAST/WEST AND
 NORTH/SOUTH) ? SAME TYPE OF TRUNCATED DOME AS THE
 BROADSTONE PROJECT INSTALLED DIRECTLY SOUTH. THE
 CURRENT ALIGNMENT PUTS PEDESTRIANS INTO THE CENTER OF
 THE INTERSECTION
 2. UPDATE CIVIL PLANS (PERMIT REVISION) TO INCLUDE
 MODIFIED ENTRIES ALONG NORTHWEST SECTION OF ALLEY
 3. PATHWAY SHALL BE ADDED FROM WESTERN ROW OF PAVERS IN
 PUBLIC PLAZA CONNECTING TO DATURA STREET SIDEWALK (AT
 LEAST 36?? WIDE AND 2% MAX SLOPE FOR ADA ACCESSIBILITY
 )
 4. THE CONCRETE CANOPY SHALL BE RELOCATED TO AN
 APPROPRIATE LOCATION PER HISTORIC PRESERVATION DIVISION
 APPROVAL. THE MAINTENANCE OF THE CANOPY SHALL BE
 DETERMINED BY DEVELOPER AND PROPERTY OWNER OF SITE
 WHERE CANOPY IS RELOCATED.
 5. REMOVAL OF EXISTING PALM TRAN BUS SHELTER SHALL BE
 COORDINATED WITH PALM TRAN. SHALL ONLY BE REMOVED WHEN
 NEW BUS SHELTER HAS BEEN MODIFIED AND OPENED FOR
 SERVICE.
 6. DEVELOPER SHALL REMOVE ALL OVERHEAD WIRES ON
 PROPERTY INCLUDING THOSE ALONG DIXIE HIGHWAY
 7. JUSTIFICATION STATEMENT SHALL BE PROVIDED BY
 DEVELOPER OUTLINING PLAN FOR CLOSURE OF EXISTING
 PARKING LOT
 8. STAFF RECOMMENDS THE UTILIZATION OF SCAFFOLDING TO
 KEEP ROW SIDEWALKS OPEN TO PUBLIC
 9. ALL FDC SHALL BE WALL MOUNTED AND PAINTED TO MATCH
 ADJACENT BUILDING FA?ADE (SUBJECT TO FIRE DEPT.
 APPROVAL). ALL ABOVE GROUND UTILITIES SHALL BE PAINTED
 TO MATCH ADJACENT FA?ADE OR LANDSCAPE BED AND SHALL BE
 SCREENED BY LANDSCAPE TO BEST EXTENT POSSIBLE
 10. ALL SIGNAGE WITHIN THE ROW THAT IS REMOVED DURING
 CONSTRUCTION SHALL BE REPLACED
 11. BACKFLOW PREVENTER SHALL BE INSTALLED IN WAY THAT
 THERE IS SUFFICIENT ROOM IN FRONT (DATURA SIDE) TO
 PROVIDE SCREENING
 12. PER EMAIL CONVERSATION WITH TRACY WARD ON DECEMBER
 27, 2019, THE DESIGN OF THE EXFILTRATION TRENCH THROUGH
 THE PUBLIC PLAZA SHALL NOT INCLUDE EXFILTRATION UNDER
 PROPOSED TREES.
 13. A MAINTENANCE AGREEMENT SHALL BE RECORDED BETWEEN
 DEVELOPER AND CITY FOR MAINTENANCE OF THE ROW WITHIN 90
 DAYS OF TCO
 14. ALL CONDITIONS FROM SITE PLAN APPROVAL THAT HAVE
 NOT BEEN SATISFIED STILL APPLY
 15. THE FOLLOWING ITEMS REQUIRE SEPARATE PERMITS:
 A. LANDSCAPE
 B. TREE REMOVAL
 C. IRRIGATION
 D. BUS SHELTER BACKING
 E. SIGNAGE
 F. PHOTOMETRICS
 16. MINOR AMENDMENT FOR AS-BUILTS SHALL BE SUBMITTED
 PRIOR TO CO (FORMAL APPLICATION TO P&Z)
 A. UPDATE FAR IN SITE PLAN DATA
 B. ALL UPDATED PLANS- CIVIL, LANDSCAPE, ARCHITECTURAL,
 ETC.
  

Review Stop Z ZONING
Rev No 2 Status F Date 2020-06-25 Cont ID  
Sent By elevesqu Date 2020-06-25 Time 16:06 Rev Time 0.00
Received By elevesqu Date 2020-06-25 Time 16:06 Sent To  
Notes
2020-06-25 16:07:261. SATISFIED ? SEE NEW PROPOSED CONDITION OF APPROVALS
 #1 AND #2
 2. SATISFIED
 3. SATISFIED
 4. SATISFIED
 5. SATISFIED
 6. SATISFIED
 7. SATISFIED
 8. SATISFIED
 9. SATISFIED
 10. SATISFIED
 11. SATISFIED
 12. SATISFIED
 13. SATISFIED
 14. SATISFIED
 15. SATISFIED
 16. SATISFIED
 17. SATISFIED
 18. COA: WHAT IS THE PLAN FOR THE CONCRETE CANOPY?
 PLEASE REMEMBER THIS WILL NEED TO BE PLANNED AND
 FINALIZED PRIOR TO CO
 19. COA: PLEASE SUBMIT SEPARATE PERMIT FOR BUS SHELTER
 BACK AND BICYCLE RACK, AND RELOCATION OF BENCH FOR BUS
 SHELTER SOUTH OF DATURA.
 20. COA: PLEASE COORDINATE WITH PALM TRAN FOR REMOVAL
 OF EXISTING BUS SHELTER ? THEY CAN REUSE THE SHELTER AT
 A DIFFERENT LOCATION.
 21. SATISFIED
 22. COA: WHAT ARE THE INTENDED PLANS FOR THE ELECTRICAL
 WIRES THAT ARE CURRENTLY RUNNING THROUGH THE EASTERN
 PORTION OF THE SITE, THAT CONNECT SOUTH TO THE
 BROADSTONE PROPERTY, AND THOSE THAT CONNECT EAST ACROSS
 DIXIE? WHAT ARE THESE UTILITIES?
 23. SATISFIED
 24. SATISFIED
 25. SATISFIED
 26. SATISFIED
 27. SATISFIED
 28. SATISFIED
 29. SATISFIED
 30. COA: PLEASE PROVIDE INFORMATION ON PLAN TO PROVIDE
 NOTICE TO USERS OF THIS LOT THAT CONSTRUCTION WILL SOON
 START AND THE LOT WILL BE CLOSED. THIS WAS DISCUSSED AT
 TIME OF CITY COMMISSION HEARING FOR THE RESTRICTIVE
 COVENANT. PLEASE PROVIDE EVIDENCE OF PLAN.
 31. COA: EXISTING PEDESTRIAN CROSSWALK SIGN ON
 QUADRILLE BOULEVARD SHALL BE REPLACED PRIOR TO CO TO
 INDICATE CROSSWALK.
 32. COA: COORDINATE WITH PUBLIC WORKS FOR THE LOCATION
 OF THE TRASH CANS THAT ARE CURRENTLY ALONG QUADRILLE
 BOULEVARD. CONTACT MATT HEJAZI
 33. COA (SUGGESTION): STAFF RECOMMENDS THE USE OF
 SCAFFOLDING TO THE MOST EXTENT POSSIBLE TO KEEP
 SIDEWALKS OPEN DURING CONSTRUCTION.
 34. SATISFIED
 35. SATISFIED
 36. COA: TDR CERTIFICATE FOR TRANSFER OF TDRS FROM
 HEART AND SOUL PARK TO 401 DATURA SHALL BE RECORDED
 PRIOR TO CO OR TDRS SHALL BE PURCHASED FROM ANOTHER
 SENDING SITE (SUBJECT TO DAC APPROVAL) IF H&S PARK
 DOESN?T SUBSTANTIALLY COMPLETE CONSTRUCTION ON TIME FOR
 THIS CERTIFICATE
 37. SATISFIED
 38. COA: PROPERTY SHALL NOT REMOVE OR RELOCATE ANY
 TREES ON SITE PRIOR TO APPROVAL OF A TREE REMOVAL
 PERMIT TO BE REVIEWED BY RAY CARANCI
 39. COA: A MAINTENANCE AGREEMENT SHALL BE APPROVED BY
 CITY COMMISSION AND APPROVED
 40. COA: THE PROPERTIES SHALL BE REPLATTED PRIOR TO CO
 THROUGH A FORMAL SUBDIVISION APPLICATION THROUGH THE
 CITY?S ZONING DEPARTMENT, SUBJECT TO CITY COMMISSION
 APPROVAL FOR MAYOR?S SIGNATURE
 41. COA: THE PROPERTY SHALL COMPLY WITH THE AIPP
 ORDINANCE PRIOR TO CO
 42. COA: PLEASE NOTE, PAVEMENT CROSSING ALLEY ON BOTH
 SIDES SHALL BE FLUSH WITH SIDEWALK TO PROVIDE FOR
 CONTINUOUS PATH OF TRAVEL
  
 NEW COMMENTS JUNE 25 2020
 43. PLEASE UPDATE BREAKDOWN OF GBA IN SITE PLAN DATA
 TABLE TO MATCH THE UPDATED BREAKDOWN FROM SHEET A-0.2
 44. FA 2.1B PARTIAL LEVEL 1 PLAN B DOES NOT MATCH
 LATEST LEVEL ONE FLOOR PLAN- PLEASE UPDATE
 45. FA 2.2B AND 2.3B PARTIAL LEVEL 2B AND 3B DO NOT
 MATCH PROPOSED PARKING LAYOUT, PLEASE REVISE
 46. PLEASE CONFIRM THAT ALL PARTIAL LEVEL PLANS MATCH
 PROPOSED FLOOR PLANS
 47. PLEASE UPDATE ADDRESSES ON ALL PLANS TO REFLECT 445
 DATURA STREET
  
 PROPOSED ADDITIONAL CONDITIONS OF APPROVAL:
 1. PLEASE COORDINATE WITH ENG. DEPT TO UPDATE THE
 TRUNCATED DOME AT THE DIXIE/DATURA CROSSING TO SPREAD
 THE ENTIRE WIDTH OF BOTH CROSSWALKS (EAST/WEST AND
 NORTH/SOUTH) ? SAME TYPE OF TRUNCATED DOME AS THE
 BROADSTONE PROJECT INSTALLED. THE CURRENT ALIGNMENT
 PUTS PEDESTRIANS INTO THE CENTER OF THE INTERSECTION
 2. UPDATE CIVIL PLANS (PERMIT REVISION) TO INCLUDE
 MODIFIED ENTRIES ALONG NORTHWEST SECTION OF ALLEY
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-05-14 Cont ID  
Sent By elevesqu Date 2020-05-14 Time 16:26 Rev Time 0.00
Received By elevesqu Date 2020-05-14 Time 16:21 Sent To  
Notes
2020-05-14 16:26:231. PLEASE SUBMIT CIVIL PLANS - PAVING, GRADING, ETC.
 2. PLEASE SUBMIT COLOR ELEVATIONS AND COLORED
 RENDERINGS AS PART OF PERMIT SET
 3. SUBMIT UPDATED FAR DIAGRAM AS THE FLOOR PLANS HAVE
 DEVELOPED AND FAR/NON FAR AREAS HAVE SHIFTED. PLEASE
 UPDATE FOR ALL FLOORS AND PROVIDE CALCULATIONS FOR EACH
 FLOOR AND TOTAL FAR.
 4. BICYCLE RACK HEIGHT SHOULD BE AROUND 35'
 5. STANDARD PARKING SPACES SHALL BE 18' MINIMUM IN
 LENGTH - PLEASE INCLUDE PARKING STALL DETAIL FROM CITY
 CODE.
 6. SITE PLAN DOES NOT MATCH LANDSCAPE PLAN IN PROJECTS
 SOUTHEAST CORNER (SURROUNDING UTILITY BOXES)
 7. THERE IS AN INCORRECT DIMENSION LABEL FOR THE
 PARKING SPACE ALONG THE ALLEY - PLEASE AMEND
 8. PARKING SPACES OFF OF ALLEY SHALL BE DOUBLE STRIPED
 - PLEASE AMEND ON SITE PLAN AND WHERE NECESSARY
 9. PLEASE INCLUDE DIMENSIONS OF CITY COMPACTOR ROOM ON
 SITE PLAN ? MUST BE MINIMUM 32'6" BY 9" PER RESTRICTIVE
 COVENANT
 10. RENAME SHEET A-0.2A FROM FAR CALCULATIONS TO
 FOOTPRINT DIAGRAMS
 11. NEW POOL EQUIPMENT ROOM WHERE SPACE WAS PREVIOUSLY
 OPEN TO FLOOR BELOW. THIS WILL NEED TO BE INCLUDED IN
 BUILDING FOOTPRINT CALCULATIONS AND PERCENTAGES.
 12. A BICYCLE RACK THAT WAS APPROVED THROUGH SITE PLAN
 APPROVAL (SHOWN ON ARCHITECTURAL PLAN SHEET A-2.1) IS
 NOT SHOWN ON THE SITE PLAN - PLEASE ENSURE BICYCLE
 RACKS ARE PROPOSED IN THE AMOUNT REQUIRED ON SITE PLAN
 AS WELL AS ARCHITECTURAL PLANS
 13. PLEASE NOTE, BICYCLE RACKS SHALL BE 2 FEET FROM
 BACK OF CURB. PLEASE MAKE SURE ALL BICYCLE RACKS MEET
 THIS REQUIREMENT AND INCLUDE DIMENSION.
 14. THERE APPEARS TO BE A SYMBOL FOR A FIRE APPARATUS
 (FDC?) WITHIN THE LANDSCAPE BED I FRONT OF THE
 BAR/GRILL AREA ON DATURA STREET - BELIEVE THIS WAS A
 GROUND MOUNTED FDC THAT WAS MOVED TO WALL MOUNTED -
 PLEASE REVISE SYMBOL LOCATION IF NECESSARY (SHOWS UP ON
 ARCHITECTURAL FLOOR PLAN LEVEL 1)
 15. PLEASE NOTE : AREA IN FRONT OF WALL MOUNTED FDC
 SHALL STILL BE LANDSCAPED, NOT CONCRETE. CANNOT
 DETERMINE FROM FIRST FLOOR PLAN WHAT AREA IS PROPOSED
 TO BE.
 16. STORAGE AREA ADJACENT TO YOGA AREA CANNOT BE
 COUNTED TOWARDS ACTIVE USE AND TRANSPARENCY
 REQUIREMENT. PLEASE CONSIDER MOVING THE STORAGE AREA
 INTERNAL TO THE WELLNESS AREA. OTHERWISE, ACTIVE USE
 AND TRANSPARENCY DIAGRAMS AND CALCULATIONS NEED TO BE
 UPDATED TO REFLECT
 17. PLEASE REMOVE NOTE :BUS SHELTER TO BE RE-LOCATED-
 AS THE EXISTING SHELTER IS BEING REMOVED FROM FLOOR
 PLAN 1. PLEASE INDICATE REMOVAL AND REPLACEMENT OF
 SHELTER BACKING AT ADJACENT SHELTER SOUTH OF DATURA
 STREET.
 18. WHAT IS THE PLAN FOR THE CONCRETE CANOPY? PLEASE
 REMEMBER THIS WILL NEED TO BE PLANNED AND FINALIZED
 PRIOR TO CO
 19. PLEASE SUBMIT SEPARATE PERMIT FOR BUS SHELTER BACK
 AND BICYCLE RACK, AND RELOCATION OF BENCH FOR BUS
 SHELTER SOUTH OF DATURA.
 20. PLEASE COORDINATE WITH PALM TRAN FOR REMOVAL OF
 EXISTING BUS SHELTER ? THEY CAN REUSE THE SHELTER AT A
 DIFFERENT LOCATION.
 21. PLEASE SUBMIT ADDITIONAL INFORMATION FOR METAL
 CANOPY ON DATURA SIDE AT LOBBY ENTRANCE INCLUDING
 WIDTH, SUPPORTS, ETC. NEED FOR DETERMINATION IF
 ENCROACHMENT EASEMENT IS REQUIRED.
 22. WHAT ARE THE INTENDED PLANS FOR THE ELECTRICAL
 WIRES THAT ARE CURRENTLY RUNNING THROUGH THE EASTERN
 PORTION OF THE SITE, THAT CONNECT SOUTH TO THE
 BROADSTONE PROPERTY, AND THOSE THAT CONNECT EAST ACROSS
 DIXIE? WHAT ARE THESE UTILITIES?
 23. PLEASE INCLUDE DEMOLITION PLAN FOR EXISTING SITE TO
 INCLUDE PLANS FOR CONCRETE CANOPY, PLANS FOR EXISTING
 SIGN, EXISTING BUS SHELTER, PAVEMENT, STRUCTURE, LIGHT
 POLES, ETC.
 24. PLEASE LABEL LOCATION OF MAST ARM AT DATURA/DIXIE
 ON SITE PLAN AND ALL PLANS THAT DON?T SHOW IT
 25. LANDSCAPE BED ALONG DIXIE HIGHWAY NEAR CORNER OF
 DATURA AND DIXIE LOOK DIFFERENT ON LEVEL 1 PLAN THAN ON
 THE SITE PLAN. PLEASE CLARIFY
 26. PLEASE EXTEND LANDSCAPE BED FROM QUADRILLE TO
 GENERATOR ROOM DOOR, AS LOCATION OF DOOR HAS SHIFTED
 FURTHER EAST. PLEASE INCLUDE SMALL HEDGE TO SCREEN
 GENERATOR LOUVRES, TO BE EXTENT POSSIBLE. COORDINATE
 WITH RAY CARANCI AND LIZ LEVESQUE.
 27. PLEASE REDUCE APRON WIDTH TO MINIMAL POSSIBLE INTO
 ALLEYWAY. PROVIDE AUTOTURN TO JUSTIFY.
 28. PER DISCUSSIONS WITH BRIAN TERRY, AND SITE PLAN
 APPROVAL CONDITION OF APPROVAL, THE TRASH COMPACTOR
 ROLLING DOORS MUST BE A MINIMUM OF 10 FEET WIDE. THE
 WESTERN MOST DOOR MUST EXPAND TO 10 FEET.
 29. NEW DOOR ADDED LEADING FROM SKY LOUNGE, FROM
 WESTERN CORRIDOR, AND FROM AN INDEPENDENT LIVING UNIT
 ALL LEADING ONTO POOL DECK ? WILL ANY OF THESE AREAS BE
 ENCLOSED? IS THIS A DOOR OR GATE? IF ENCLOSED AND AC,
 SHALL COUNT TOWARDS FAR.
 30. PLEASE PROVIDE INFORMATION ON PLAN TO PROVIDE
 NOTICE TO USERS OF THIS LOT THAT CONSTRUCTION WILL SOON
 START AND THE LOT WILL BE CLOSED. THIS WAS DISCUSSED AT
 TIME OF CITY COMMISSION HEARING FOR THE RESTRICTIVE
 COVENANT. PLEASE PROVIDE EVIDENCE OF PLAN.
 31. EXISTING PEDESTRIAN CROSSWALK SIGN ON QUADRILLE
 BOULEVARD SHALL BE REPLACED PRIOR TO CO TO INDICATE
 CROSSWALK.
 32. COORDINATE WITH PUBLIC WORKS FOR THE LOCATION OF
 THE TRASH CANS THAT ARE CURRENTLY ALONG QUADRILLE
 BOULEVARD. CONTACT MATT HEJAZI
 33. STAFF RECOMMENDS THE USE OF SCAFFOLDING TO THE MOST
 EXTENT POSSIBLE TO KEEP SIDEWALKS OPEN DURING
 CONSTRUCTION.
 34. PLEASE SUBMIT HARDSCAPE PLAN
 35. LANDSCAPE TO BE REVIEWED THROUGH SEPARATE PERMIT
 36. TDR CERTIFICATE FOR TRANSFER OF TDRS FROM HEART AND
 SOUL PARK TO 401 DATURA SHALL BE RECORDED PRIOR TO CO
 OR TDRS SHALL BE PURCHASED FROM ANOTHER SENDING SITE
 (SUBJECT TO DAC APPROVAL) IF H&S PARK DOESN?T
 SUBSTANTIALLY COMPLETE CONSTRUCTION ON TIME FOR THIS
 CERTIFICATE
 37. RESTRICTIVE COVENANT FOR VALET OPERATION AND FOR
 TANDEM PARKING SPACES SHALL BE RECORDED BY CITY
 COMMISSION PRIOR TO CO
 38. PROPERTY SHALL NOT REMOVE OR RELOCATE ANY TREES ON
 SITE PRIOR TO APPROVAL OF A TREE REMOVAL PERMIT TO BE
 REVIEWED BY RAY CARANCI
 39. A MAINTENANCE AGREEMENT SHALL BE APPROVED BY CITY
 COMMISSION AND APPROVED
 40. THE PROPERTIES SHALL BE REPLATTED PRIOR TO CO
 THROUGH A FORMAL SUBDIVISION APPLICATION THROUGH THE
 CITY?S ZONING DEPARTMENT, SUBJECT TO CITY COMMISSION
 APPROVAL FOR MAYOR?S SIGNATURE
 41. THE PROPERTY SHALL COMPLY WITH THE AIPP ORDINANCE
 PRIOR TO CO
 42. PLEASE NOTE, PAVEMENT CROSSING ALLEY ON BOTH SIDES
 SHALL BE FLUSH WITH SIDEWALK TO PROVIDE FOR CONTINUOUS
 PATH OF TRAVEL
 SUBJECT TO FURTHER COMMENT WITH FURTHER REVIEW
  
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426