Plan Review Details - Permit 20011077
Plan Review Stops For Permit 20011077
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-03-27 Cont ID  
Sent By rmcphers Date 2020-03-27 Time 08:03 Rev Time 0.00
Received By rmcphers Date 2020-03-27 Time 08:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-28 Cont ID  
Sent By rmcphers Date 2020-01-28 Time 13:52 Rev Time 0.00
Received By rmcphers Date 2020-01-28 Time 13:51 Sent To  
Notes
2020-01-28 13:58:50****CORRECTIONS****
  
 ROGER MCPHERSON
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1) BUILDING PERMIT APPLICATION SHOWS 1 DOOR REPLACEMENT
 - PROVIDED COPY OF THE CONTRACT SHOWS NEW DOOR OPENING.
 (PLEASE CLARIFY ON THE APPLICATION). FBC 107.2
 2) PLEASE PROVIDE STRUCTURAL DETAILS FOR THE DOOR
 OPENING. FBC R301.2.1
 3) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF
 THE NEW DOORS. FBC R 107.3.5.3
 4) PLEASE PROVIDE THE COMPLETE FLORIDA PRODUCT APPROVAL
 ( FRONT PAGES ARE MISSING). FBC R301.2.1.2
 5) PRODUCT APPROVAL SUPPLIED DOES NOT MEET IMPACT
 REQUIREMENTS - PLEASE PROVIDE A PRODUCT APPROVAL FOR
 THE REQUIRED SHUTTERS. FBC R 301.2.1.2
 6) CONTRACTORS SIGNATURE ON THE PROVIDED PERMIT
 APPLICATION NEEDS TO BE NOTARIZED AS VALUE APPEARS TO
 BE MORE THAN $2500.00 FBC 107
 7) PLEASE SHOW JOB COST BREAK DOWN PER FBC 109.3
 8) 1. FBC R 301, COMPLETE THE "SCHEDULE FOR
 INSTALLATION OF OPENING PROTECTIVE DEVICES" OR PROVIDE
 ALL INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS
 EXCEL SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2020-03-24 Cont ID  
Sent By jpearson Date 2020-03-24 Time 13:52 Rev Time 0.00
Received By jpearson Date 2020-03-24 Time 13:52 Sent To B
Notes
2020-03-24 13:52:04SEPARATE ELECTRICAL PERMIT REQUIRED FOR EXTERIOR LIGHT
 PER FBC RE E3903.3.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-01-31 Cont ID  
Sent By jleahy Date 2020-01-31 Time 10:43 Rev Time 0.00
Received By jleahy Date 2020-01-31 Time 10:43 Sent To  
Notes
2020-01-31 10:44:46FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NEW EXTERIOR OPENING WILL REQUIRE AN EGRESS LIGHT AND
 POSSIBLE SWITCH.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-27 Cont ID  
Sent By rmcphers Date 2020-03-27 Time 08:03 Rev Time 0.00
Received By rmcphers Date 2020-03-20 Time 14:46 Sent To  
Notes
2020-03-27 08:05:01PLANS TAKEN TO PERMIT LIBRARY
2020-03-20 14:46:11ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-31 Cont ID  
Sent By jleahy Date 2020-01-31 Time 10:44 Rev Time 0.00
Received By jleahy Date 2020-01-27 Time 16:10 Sent To  
Notes
2020-01-28 14:57:48PLANS TAKEN TO ELEC. PLAN REVIEW