Plan Review Details - Permit 20011032
Plan Review Stops For Permit 20011032
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-03-11 Cont ID  
Sent By ccole Date 2020-03-11 Time 16:40 Rev Time 0.00
Received By jleahy Date 2020-03-11 Time 16:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-11 Cont ID  
Sent By jleahy Date 2020-03-11 Time 16:40 Rev Time 0.00
Received By jleahy Date 2020-02-24 Time 13:07 Sent To  
Notes
2020-02-27 16:51:522/27 ROUTED TO ELECTRICAL INBOX
2020-02-25 13:07:20RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-02-13 Time   Rev Time 0.00
Received By lmarchan Date 2020-02-11 Time 13:42 Sent To  
Notes
2020-02-12 13:43:03RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-02-03 Time   Rev Time 0.00
Received By lmarchan Date 2020-01-27 Time 13:19 Sent To  
Notes
2020-01-28 13:19:12MECHANICAL INBOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-02-26 Cont ID  
Sent By ccole Date 2020-02-26 Time 09:56 Rev Time 0.00
Received By ccole Date 2020-02-26 Time 09:52 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-02-13 Cont ID  
Sent By ccole Date 2020-02-13 Time 08:33 Rev Time 0.00
Received By ccole Date 2020-02-13 Time 08:33 Sent To I
Notes
2020-02-13 08:47:232ND REVIEW FBC-2017 MECHANICAL
 PERMIT #20011032
 2/13/20
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE AC PLAN IS INCOMPLETE.
  
 A) PROVIDE RETURN AIR FROM THE BEDROOMS- SECTION
 M1602.3 FBC RES.
  
 B) SHOW THE SUPPLY CFMS AT EACH DIFFUSER LOCATION-
 M1601.1 FBC RES.
  
 C) VERIFY 10' CLEARANCE FROM THE COOKING APPLIANCES TO
 THE MAIN RETURN IN THE KITCHEN- M1602.2 FBC RES
  
 D) NO ACCESS TO AIR HANDLER IN ATTIC SHOWN- M1305.1.3
 FBC RES
  
 D) LOCATION OF CONDENSER AND INSTALLATION DETAIL NOT
 PROVIDED- M1305.1.4.1 & M1401.4 FBC RES.
  
 2) NO ELECTRICAL PLAN SUBMITTED TO INDICATE CIRCUITRY,
 WIRE AND BREAKER SIZES- SECTION 107.2.1 WPB.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK "VOID" OR "OLD" ON THEM. PLEASE
 RETAIN THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS.
 THIS PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-02-03 Cont ID  
Sent By ccole Date 2020-02-03 Time 10:51 Rev Time 0.00
Received By ccole Date 2020-02-03 Time 10:50 Sent To I
Notes
2020-02-03 11:02:341ST REVIEW FBC-2017 MECHANICAL
 PERMIT #20011032
 2/3/20
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) NO AC PLANS WERE SUBMITTED FOR REVIEW. THERE ARE TWO
 COPIES OF THE PROPERTY SURVEY SUBMITTED. PLEASE SHOW
 THE LOCATION OF THE NEW CONDENSER ON THE SURVEY WITH
 SETBACK CLEARANCES TO THE ADJOINGING PROPERTY LINE(S)-
 SECTION 107.2.1 WPB.
  
 2) PLEASE NOT THAT THE PB PROPERTY APPRAISER REPORT
 INDICATES THAT THE RESIDENCE CURRENTLY HAS NO HEATING
 OR COOLING SYSTEMS. THIS IS A NEW INSTALLATION THAT
 REQUIRES ENERGY AND AC CALCULATIONS, AND AN ELECTRICAL
 PLAN.
  
 PREVIOUSLY UNCONDITIONED BUILDINGS:
  
 A) ENERGY COMPLIANCE REPORT- SECTION R503.2 FBC EC.
  
 B) AC COOLING AND HEATING CALCULATIONS- SECTION
 R403.6.1 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK "VOID" OR "OLD" ON THEM. PLEASE
 RETAIN THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS.
 THIS PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-02-27 Cont ID  
Sent By rfalcone Date 2020-02-27 Time 16:07 Rev Time 0.00
Received By rfalcone Date 2020-02-27 Time 16:07 Sent To I
Notes
***NONE***