Plan Review Details - Permit 20010742
Plan Review Stops For Permit 20010742 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-03-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-18 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-18 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-01-23 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-01-23 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-01-23 |
Time |
14:47 |
Sent To |
|
|
Notes |
2020-01-23 14:47:37 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | 805-6724 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | 1. FBC EB 504.1 REVISE DRAWINGS TO REFLECT LEVEL 2 | | ALTERATION. | | 2. FBC EB 801.1 & 801.2 LEVEL 2 ALTERATIONS AS | | DESCRIBED IN SECTION 504 SHALL COMPLY WITH THE | | REQUIREMENTS OF CHAPTER 8. IN ADDITION TO THE | | REQUIREMENTS OF THIS CHAPTER, ALL WORK SHALL COMPLY | | WITH THE REQUIREMENTS OF CHAPTER 7. | | 3. FBC B 107.2.1 PROVIDE FRAMING DETAILS SUPPLIED FOR | | ALL NEW WALLS/CEILINGS/INFILLS/SOFFITS. SHOW ANCHORAGE, | | BRACING AND BLOCKING | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-03-18 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-03-18 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-03-18 |
Time |
14:27 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-01-26 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-01-26 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-01-26 |
Time |
12:40 |
Sent To |
I |
|
Notes |
2020-01-26 12:40:41 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | 107.1, 107.2.1, 107.3.5.1.2 | | 2. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | NEW INSTALLATIONS, OR PROVIDE A NOTE REQUIRING | | COMPLIANCE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-03-18 |
Time |
|
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-18 |
Time |
14:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-01-26 |
Time |
|
Rev Time |
|
Received By |
jbrooks |
Date |
2020-01-17 |
Time |
14:09 |
Sent To |
|
|
Notes |
2020-01-24 12:48:36 | ROUTED TO ELECTRICAL |
|
|
|