Plan Review Details - Permit 20010685
Plan Review Stops For Permit 20010685
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-02-07 Cont ID  
Sent By jgomez Date 2020-02-07 Time 10:24 Rev Time 0.00
Received By jgomez Date 2020-02-07 Time 10:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-17 Cont ID  
Sent By jgomez Date 2020-01-17 Time 18:10 Rev Time 0.00
Received By jgomez Date 2020-01-17 Time 17:57 Sent To  
Notes
2020-01-17 18:10:21RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- FLAT ROOF NOA 18-0919.12 SUBMITTED: SELECTED
 ASSEMBLY ON PAGE 53 OF 67 DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED AND SEALED
 RAS 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER
 AND CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7
 ON LAST PAGE OF NOA. NEED THE CALCULATIONS TO MEET THE
 DESIGN PRESSURES REQUIRED BY SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-07 Cont ID  
Sent By jgomez Date 2020-02-07 Time 10:25 Rev Time 0.00
Received By jgomez Date 2020-02-05 Time 16:20 Sent To I
Notes
2020-02-06 16:20:54RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-17 Cont ID  
Sent By jgomez Date 2020-01-17 Time 18:10 Rev Time 0.00
Received By jgomez Date 2020-01-17 Time 17:56 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved