Plan Review Stops For Permit 20010435 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2020-01-15 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-01-15 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-01-15 |
Time |
11:48 |
Sent To |
|
|
Notes |
2020-01-15 11:49:19 | ADDRESS ADDED | 2020-01-13 15:09:09 | SHOULD BE SUITE 1301 |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
3 |
Status |
P |
Date |
2020-03-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-03-04 |
Time |
06:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-03-04 |
Time |
06:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
F |
Date |
2020-02-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-02-24 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-02-24 |
Time |
10:23 |
Sent To |
|
|
Notes |
2020-02-24 10:45:12 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | | |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2020-01-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-01-22 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-01-22 |
Time |
10:58 |
Sent To |
|
|
Notes |
2020-01-22 10:59:56 | ASBESTOS COMMERCIAL. PLEASE PROVIDE A SIGNED | | ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD, | | STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF | | ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF | | HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT | | NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL | | INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE | | FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-02-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-02-24 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-02-24 |
Time |
10:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2020-01-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-01-22 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-01-22 |
Time |
10:58 |
Sent To |
|
|
Notes |
2020-01-22 12:42:27 | PLANS ARE CODE COMPLIANT BUT CAN NOT BE SIGNED BY THE | | PLAN REVIEWER, SINCE THE ARCHITECTURAL SHEETS DO NOT | | HAVE ELECTRONIC SIGNATURE AND SEAL. JW |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-03-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-03-01 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-03-01 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-01-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-01-29 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-01-29 |
Time |
13:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-02-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-02-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-02-21 |
Time |
11:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-01-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-01-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-01-24 |
Time |
16:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-03-17 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-02-20 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-01-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-01-29 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-01-14 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2020-01-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-01-22 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-01-22 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-03-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-02 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-02 |
Time |
08:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-01-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-01-24 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-01-23 |
Time |
17:08 |
Sent To |
|
|
Notes |
2020-01-24 08:49:23 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #20010435 | | 1/24/20 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS M2.1 & A0.02: FIRE DAMPER MISSING AT THE NEW | | 32X24 RETURN AIR GRILL- SECTION 607.5.2 FBC M. | | | | 2) M2.1: SUBMIT ENGINEERING FOR INSTALLATION OF THE | | ROOFTOP CONDENSER- SECTION 301.15 FBC M. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-03-17 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-03-17 |
Time |
08:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-01-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2020-01-29 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2020-01-29 |
Time |
12:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-03-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-03-04 |
Time |
06:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-03-04 |
Time |
06:47 |
Sent To |
|
|
Notes |
2020-03-02 08:23:12 | MECHANICAL PLANS GOOD- CCOLE-3/2/2020 | 2020-02-24 10:46:35 | 2ND SIGNATURE REVIEW 2/24/2020 ARCHITECTURAL SHEETS ARE | | ALL ELECTRONICALLY SIGNED AND SEALED. JW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-01-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-01-22 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2020-01-29 12:45:59 | PLUMB SHEETS NOT DIG SIGNED AND SEALED/GPJ 1/29/20 | 2020-01-23 17:16:59 | MECHANICAL PLANS NOT ELECTRONICALLY SIGNED AND SEALED- | | FL. STATUTE 471.025 AND SECTION 61G15-23.005 FLORIDA | | ADMINISTRATIVE CODE. | | CCOLE | 2020-01-22 12:39:27 | 1/22/2020. NONE OF THE SUBMITTED SHEETS HAVE AN | | ELECTRONIC SIGNATURE. JW |
|
|