Plan Review Details - Permit 20010140
Plan Review Stops For Permit 20010140 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-02-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-02-14 |
Time |
06:34 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-02-14 |
Time |
06:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-01-27 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-01-27 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-01-27 |
Time |
10:34 |
Sent To |
|
|
Notes |
2020-01-27 12:53:20 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | FBC B 109.3, THE VALUATION APPEARS TO BE LOW. PLEASE | | RE-EVALUATE AND PROVIDE A BREAK DOWN OF COST INCLUDING | | ALL WORK INVOLVED UNDER THIS PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2020-01-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-01-27 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-01-27 |
Time |
15:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-01-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-01-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-01-23 |
Time |
13:41 |
Sent To |
B |
|
Notes |
2020-01-23 13:42:40 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) ANY WORK INVOLVING FIRE ALARM EQUIPMENT SHALL BE | | DONE UNDER SEPARATE SHOP DRAWINGS. | | | | PLEASE ENSURE COMPLIANCE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-02-14 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-02-14 |
Time |
06:39 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-02-04 |
Time |
13:55 |
Sent To |
|
|
Notes |
2020-02-13 06:56:04 | ROUTED TO PVALENTI INBOX | 2020-02-05 13:55:12 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-02-05 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-02-05 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-01-06 |
Time |
14:13 |
Sent To |
|
|
Notes |
2020-01-22 16:22:41 | ROUTED TO FIRE | 2020-01-07 14:13:22 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-02-12 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-02-12 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-02-12 |
Time |
14:10 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-01-21 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-01-21 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-01-21 |
Time |
16:15 |
Sent To |
I |
|
Notes |
2020-01-21 16:15:42 | 1/21/20 FAILED. | | | | PLEASE PROVIDE A SURVEY OF THE SUBJECT SITE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | DEVELOPMENT SERVICES DEPARTMENT | | E-MAIL: [email protected] | | TEL: (561) 822-1442 | | |
|
|
|