Plan Review Details - Permit 20010067
Plan Review Stops For Permit 20010067
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-27 Cont ID  
Sent By pvalenti Date 2020-01-27 Time 14:54 Rev Time 0.00
Received By pvalenti Date 2020-01-27 Time 14:27 Sent To  
Notes
2020-01-27 15:10:01***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 1. FLORIDA STATUTES SECTION 489.103, OWNER/BUILDER
 DISCLOSURE STATEMENT ITEM #4 STATES THAT THE BUILDING
 OR RESIDENCE MUST BE FOR THE OWNER'S OWN USE OR
 OCCUPANCY. IT MAY NOT BE BUILT OR SUBSTANTIALLY
 IMPROVED FOR SALE OR LEASE.
  
 PLEASE NOTE THAT THE SUBMITTAL OF ADDITIONAL COMMENTS
 MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-01-10 Cont ID  
Sent By jpearson Date 2020-01-10 Time 12:17 Rev Time 0.00
Received By jpearson Date 2020-01-10 Time 11:39 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-01-31 Cont ID  
Sent By fmittner Date 2020-01-31 Time 10:21 Rev Time 0.00
Received By fmittner Date 2020-01-31 Time 10:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-31 Cont ID  
Sent By ccarvaja Date 2020-01-31 Time 10:50 Rev Time 0.00
Received By ccarvaja Date 2020-01-03 Time 13:08 Sent To  
Notes
2020-01-06 13:08:50R09

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-01-22 Cont ID  
Sent By ccole Date 2020-01-22 Time 16:35 Rev Time 0.00
Received By ccole Date 2020-01-22 Time 16:34 Sent To  
Notes
2020-01-22 16:49:261ST REVIEW FBC-2017 MECHANICAL
 PERMIT #20010067
 1/22/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) ACCORDING TO THE PALM BEACH COUNTY APPRAISER'S
 REPORT AND WEST PALM BEACH PERMIT RECORDS, THE EXISTING
 AC SYSTEM WAS NEVER LEGALLY PERMITTED AND MUST NOW MEET
 COMPLIANCE AS A NEW SYSTEM BEING INSTALLED IN A
 PREVIOUSLY UNCONDITIONED BUILDING. PLEASE PROVIDE THE
 FOLLOWING:
  
 A) ENERGY COMPLIANCE REPORT- SECTION R503.2 FBC EC.
  
 B) AC COOLING AND HEATING CALCULATIONS- SECTION
 R403.6.1 FBC EC.
  
 2) PROVIDE AN AC EQUIPMENT SCHEDULE ON THE PLAN THAT
 INCLUDES THE MAKE AND MODEL NUMBERS OF THE CONDENSER
 AND THE AIR HANDLER, COOLING AND HEATING CAPACITIES,
 TOTAL AIRFLOW CFMS, AND EFFICIENCY RATING- TABLE
 C403.2.3(1) FBC EC.
  
 3) EXHAUST VENTILATION FOR THE KITCHEN AT A RATE OF 100
 CFMS INTERMITTENT OR 25 CFMS CONTINUOUS IS REQUIRED PER
 TABLE M1507.4 FBC RES. INDICATE IF A RANGE HOOD WILL BE
 INSTALLED OR HOW COMPLIANCE WILL BE MET- SEE M1503 FBC
 RES.
  
 4) INDICATE HOW THE NEW BATHROOM WILL BE VENTILATED-
 REFER TO SECTION R303.3 AND M1507 FBC RES.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-01-07 Cont ID  
Sent By jesmith Date 2020-01-07 Time 08:47 Rev Time 0.00
Received By jesmith Date 2020-01-07 Time 08:21 Sent To  
Notes
2020-01-07 08:47:08CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
 1. PLAN SHEET A-2: SANITARY RISER; BATHTUB FIXTURE
 DRAIN SHALL CONNECT TO THE HORIZONTAL WET VENT UPSTREAM
 OF THE SINK CONNECTION TO COMPLY WITH FBC RES P3108.1.
 2. PLAN SHEET A-2: SANITARY RISER; HORIZONTAL DRAIN
 SERVICING THE WASHER IS SIZED 2 INCH BY THE DESIGNER
 AND HAS BEEN MODIFIED BY HAND TO REFLECT 3 INCH SIZE.
 PER WPB FBC 107.2.1, REVISE TO REFLECT 3 INCH SIZE.
 NOTE THAT MOST MANUFACTURER?S RECOMMENDATIONS DO
 REQUIRE THAT THE DRAIN BE 3 INCH.
 3. PLAN SHEET A-2: SANITARY RISER AND PLAN VIEW;
 PROVIDE A CLEANOUT AT OR NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND BUILDING SEWER TO COMPLY WITH FBC
 RES P3005.2.3.
 4. PLAN SHEET A-2: NOTE 11; SELECTED WATER HEATER
 PROVIDES A MAXIMUM OF 3.1 GPM. THIS APPEARS NOT TO
 SATISFY THE REQUIREMENTS FOR HOT WATER FOR THE FIXTURES
 REQUIRING HOT WATER. PER WPB FBC 107.2.1, PROVIDE
 CALCULATIONS FOR THE HOT WATER DEMAND AND INSURE THAT
 THE SELECTED WATER HEATER WILL SATISFY THE
 REQUIREMENTS.
 5. PER THE WPB UTILITIES DEPTMENT, A RPZ BACKFLOW
 PREVENTOR SHALL BE INSTALLED AT THE WATER SERVICE TO
 THE PROPERTY COMPLYING WITH WPB CCCM. PER WPB FBC
 107.2.1, PROVIDE NOTE ON PLAN SHEET A-1 AND A-2.
 6. SUBMIT TWO COPIES OF A SLAB REPAIR DETAIL FOR
 REVIEW. SHOW THE WIDTH OF THE REPAIR, THE MINIMUM
 THICKNESS OF THE CONCRETE TO BE REPLACED AND THE PSI OF
 THE CONCRETE. SHOW SIZE AND LENGTH OF DOWELS, THE
 MINIMUM DEPTH INTO EXISTING SLAB, ANCHORING MATERIAL
 FOR DOWELS AND THE SPACING OF THE DOWELSON CENTER. THE
 REPAIR SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL
 AND THE REQUIRED VAPOR BARRIER OVER WELL COMPACTED
 SOIL. A COPY OF THE TERMITE CERTIFICATION SHALL BE
 ONSITE FOR THE FINAL INSPECTION. REFER TO FBC RES
 R318.1.1, R402.2, R404.1.3.3.7.1, R501.2, R506.1 AND
 R506.2.3.
  
  
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
 GAS COMMENTS:
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 20010067 747 ARDMORE RD
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-01-31 Cont ID  
Sent By awooten Date 2020-01-31 Time 10:22 Rev Time 0.00
Received By fmittner Date 2020-01-31 Time 10:22 Sent To  
Notes
***NONE***