Plan Review Details - Permit 19121129
Plan Review Stops For Permit 19121129
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-27 Cont ID  
Sent By jbrooks Date 2020-01-27 Time 11:59 Rev Time 0.00
Received By jbrooks Date 2020-01-27 Time 11:59 Sent To  
Notes
2020-01-27 12:00:40JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561)
 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 1. FBC B 107.2.1 PLEASE ADDRESS ZONING COMMENTS AND
 SUBMIT NEW WIND DESIGN INSTALLATION DATA. (IF
 APPLICABLE).
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-01-26 Cont ID  
Sent By jpearson Date 2020-01-26 Time 12:59 Rev Time 0.00
Received By jpearson Date 2020-01-26 Time 12:59 Sent To B
Notes
2020-01-26 12:59:00CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3
 2. PROVIDE EXTERIOR LIGHTING CONTROLS AS SPECIFIED IN
 THE FBC ENERGY CONSERVATION. FBC EC C405.2.5
 3. PROVIDE EQUIPMENT GROUNDING CONDUCTOR TO SIGN. NEC
 600.7
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-27 Cont ID  
Sent By jbrooks Date 2020-01-27 Time 12:00 Rev Time 0.00
Received By jbrooks Date 2019-12-31 Time 15:12 Sent To  
Notes
2020-01-02 15:12:39ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status F Date 2020-01-14 Cont ID  
Sent By eschneid Date 2020-01-14 Time 11:34 Rev Time 0.25
Received By eschneid Date 2020-01-10 Time 17:01 Sent To E
Notes
2020-01-14 13:39:49FAILED
  
 1) THE FULL DIMENSION OF THE SIGN IS NOT PROVIDED ON
 THE PLANS. IN ACCORDANCE WITH THE ROSEMARY SQUARE
 TENANT SIGN CRITERIA REQUIRES THAT THE SIGN AREA IS
 CALCULATED USING THE MAXIMUM EXTENT OF THE SIGN.
 PROVIDE THE DIMENSION OF THE VERTICAL BAR BETWEEN LA
 AND FITNESS.
  
 2) THE SIGN SQUARE FOOTAGE ALLOWANCE IS BASED ON THE
 LINEAR FRONTAGE OF THE TENANT SPACE. PROVIDE THE
 FRONTAGE DIMENSION OF THE ENTIRE LA FITNESS SPACE.
  
 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A
 MAXIMUM LETTER HEIGHT OF 18 INCHES FOR A FASCIA SIGN
 UNLESS CITYPLACE RETAIL GRANTS A WAIVER II (MINOR
 PLANNED DEVELOPMENT AMENDMENT). THE WAIVER II MAY
 INCREASE THE SIGNS DIMENSION BY UP TO 25 PERCENT, SO
 THE LETTER HEIGHT (INCLUDING THE VERTICAL BAR) COULD BE
 UP TO 22.5 INCHES.
  
 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT REVERSE CHANNEL LETTERS ARE FABRICATED OUT OF
 ALUMINUM WITH A MINIMUM METAL THICKNESS OF .060 INCHES.
 THE SIGN DETAIL DOES NOT SPECIFY THE UNIT OF
 MEASUREMENT FOR THE ALUMINUM LETTERS.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE
 STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR
 BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE
 PLANS. NOTE: IT APPEARS THAT ALUMINUM STUDS ARE BEING
 USED INSTEAD OF THE STAINLESS STEEL.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  