Plan Review Details - Permit 19121035
Plan Review Stops For Permit 19121035
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2020-02-14 Cont ID  
Sent By rmcphers Date 2020-02-14 Time 15:03 Rev Time 0.00
Received By rmcphers Date 2020-02-14 Time 15:03 Sent To  
Notes
2020-02-14 14:00:11 
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-06-16 Cont ID  
Sent By rmcphers Date 2020-06-16 Time 10:28 Rev Time 0.00
Received By rmcphers Date 2020-06-16 Time 10:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-05-22 Cont ID  
Sent By rmcphers Date 2020-05-20 Time 15:25 Rev Time 0.00
Received By rmcphers Date 2020-05-20 Time 15:25 Sent To  
Notes
2020-05-22 08:06:34OUTDOOR AREA
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED -
 1) GATES CANNOT BE MORE THAN 4 FEET WIDE - FBC 1010.2 -
 - FBC 1010.1.1
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-14 Cont ID  
Sent By rmcphers Date 2020-02-14 Time 14:01 Rev Time 0.00
Received By rmcphers Date 2020-02-14 Time 07:48 Sent To  
Notes
2020-02-14 15:01:25COURTYARD RENOVATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED -
 1) THE ENCLOSED COURT YARD HAS ADDED OCCUPANT LOAD TO
 THE BUILDING AS A WHOLE. PLEASE PROVIDE A LIFE SAFETY
 PLAN FOR THE ENTIRE BUILDING SHOWING ALL EGRESS
 COMPONENTS, OCCUPANT LOAD, MEANS OF EGRESS, EXIT ACCESS
 TRAVEL DISTANCE, EXIT WIDTHS ETC. FBC 1004.1
 2) PLEASE SHOW THE EXIT GATES/DOORS SEPARATION TO
 COMPLY WITH FBC 1007
 3) 3 OR MORE EXITS FROM THE ADDED COURTYARD MAY BE
 REQUIRED PER FBC 1006.2.1.1 (OCCUPANT LOAD NEEDS TO BE
 BASED ON USE OF THE SPACE PER FBC 1004 - NOT WHAT YOU
 SAY AS "ACTUAL".
 4) PLEASE SHOW EXIT SIGNAGE AT EACH REQUIRED EXIT PER
 FBC 1013.1
 5) PLEASE SHOW THE " FUNCTION OF THE SPACE" FOR THE
 COURTYARD PER FBC 1004.1.2
 6) PLEASE STATE ON THE DRAWINGS THAT THE OCCUPANT LOAD
 SHALL BE POSTED PER FBC 1004.3
 7) PLEASE PROVIDE SPECS FOR THE "PANIC HARDWARE" TO
 COMPLY WITH FBC 1010.1.10.1
 8) PLEASE PROVIDE A STATEMENT ON THE DRAWINGS THAT THE
 ELECTROMAGNETICALLY LOCKED GATES/DOORS SHALL RELEASE BY
 THE PUSH OF THE PANIC HARDWARE PER FBC 1010.1.9.9 (5)
 9) PLEASE SHOW ALL WALKING AREAS TO COMPLY WITH FBC
 ACCESSIBILITY (ACCESSIBLE ROUTES ETC.) CHAPTER 4
 10) PLEASE PROVIDE A SOIL REPORT FBC 1803.2
 11) PLEASE PROVIDE EXTERIOR PERIMETER WALL DETAILS. FBC
 WPB AMENDMENTS 107
 12) "SCULPTURAL STRUCTURAL DRAWINGS" AND "ELECTRICAL"
 DRAWINGS DO NOT SHOW IN "ADOBE" AS ELECTRONICALLY
 SIGNED. THIS WILL NEED TO BE CORRECTED.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-06-17 Cont ID  
Sent By jpearson Date 2020-06-17 Time 13:45 Rev Time 0.00
Received By jpearson Date 2020-06-17 Time 13:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-05-21 Cont ID  
Sent By jpearson Date 2020-05-21 Time 14:10 Rev Time 0.00
Received By jpearson Date 2020-05-21 Time 13:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-02-25 Cont ID  
Sent By jpearson Date 2020-02-25 Time 08:00 Rev Time 0.00
Received By jpearson Date 2020-02-25 Time 08:00 Sent To  
Notes
2020-02-25 08:00:07CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. FIRE ALARM, LOW VOLTAGE SYSTEMS, DAS, LIGHTNING
 PROTECTION, GENERATORS, COMMERCIAL HOOD SYSTEMS, WALK
 IN COOLERS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS
 (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF
 THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND PLAN SUBMITTALS FOR ANY
 OF THESE SYSTEMS PRESENT. WPB FBC 105.1, 107.2.1
 2. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF
 PLAN IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A
 DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY
 VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1; FS
 471/481
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2020-05-14 Cont ID  
Sent By rrossano Date 2020-05-14 Time   Rev Time 0.00
Received By rrossano Date 2020-05-14 Time   Sent To  
Notes
2020-05-14 14:25:07UNDER FORMAL ENGINEERING REVIEW.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2020-02-04 Cont ID  
Sent By rrossano Date 2020-02-04 Time   Rev Time 0.00
Received By rrossano Date 2020-02-04 Time   Sent To  
Notes
2020-02-04 08:11:57PLEASE ADDRESS ZONING COMMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-04-30 Cont ID  
Sent By pleduc Date 2020-04-30 Time   Rev Time 0.00
Received By pleduc Date 2020-04-29 Time 12:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-01-15 Cont ID  
Sent By pleduc Date 2020-01-15 Time   Rev Time 0.00
Received By pleduc Date 2020-01-15 Time 12:14 Sent To  
Notes
2020-01-15 12:36:26THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE IS NO LIFE SAFETY PLAN INDICATING REQUIRED
 EGRESS CAPACIY IS MET, INCLUDING THE IMPACT OF EGRESS
 INCREASES ON ADJACENT EXISTING EGRESS ROUTES.
  
 PER NFPA 1
  
 4.1.3.2.2.3 BUILDINGS SHALL BE DESIGNED AND CONSTRUCTED
 TO PROVIDE
 REASONABLE LIFE SAFETY FOR OCCUPANTS AND WORKERS DURING
 CONSTRUCTION AND DEMOLITION.
  
 4.4.3.1 UNOBSTRUCTED EGRESS.
 4.4.3.1.1 IN EVERY OCCUPIED BUILDING OR STRUCTURE,
 MEANS OF
 EGRESS FROM ALL PARTS OF THE BUILDING SHALL BE
 MAINTAINED FREE AND
 UNOBSTRUCTED.
  
 4.4.3.1.3 MEANS OF EGRESS SHALL BE ACCESSIBLE TO THE
 EXTENT
 NECESSARY TO ENSURE REASONABLE SAFETY FOR OCCUPANTS
 HAVING
 IMPAIRED MOBILITY.
 4.4.3.2 AWARENESS OF EGRESS SYSTEM.
 4.4.3.2.1 EVERY EXIT SHALL BE CLEARLY VISIBLE, OR THE
 ROUTE TO REACH
 EVERY EXIT SHALL BE CONSPICUOUSLY INDICATED.
 4.4.3.2.2 EACH MEANS OF EGRESS, IN ITS ENTIRETY, SHALL
 BE ARRANGED
 OR MARKED SO THAT THE WAY TO A PLACE OF SAFETY IS
 INDICATED IN A
 CLEAR MANNER.
  
 4.5.6 CONSTRUCTION, REPAIR, AND IMPROVEMENT OPERATIONS.
 4.5.6.1 BUILDINGS OR PORTIONS OF BUILDINGS SHALL BE
 PERMITTED TO BE
 OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATIONS, OR
 ADDITIONS ONLY
 WHERE REQUIRED MEANS OF EGRESS AND REQUIRED FIRE
 PROTECTION
 FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED FOR
 THE PORTION
 OCCUPIED OR WHERE ALTERNATIVE LIFE SAFETY MEASURES AND
 BUILDING
 PROTECTION MEASURES ACCEPTABLE TO THE AHJ ARE IN PLACE.
  
 NFPA 101
  
 4.6.10 CONSTRUCTION, REPAIR, AND IMPROVEMENT
 OPERATIONS.
 4.6.10.1* BUILDINGS, OR PORTIONS OF BUILDINGS, SHALL BE
 PERMITTED TO
 BE OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATIONS,
 OR ADDITIONS
 ONLY WHERE REQUIRED MEANS OF EGRESS AND REQUIRED FIRE
 PROTECTION
 FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED FOR
 THE PORTION
 OCCUPIED OR WHERE ALTERNATIVE LIFE SAFETY MEASURES
 ACCEPTABLE TO
 THE AUTHORITY HAVING JURISDICTION ARE IN PLACE.
 4.6.10.2* IN BUILDINGS UNDER CONSTRUCTION, ADEQUATE
 ESCAPE
 FACILITIES SHALL BE MAINTAINED AT ALL TIMES FOR THE USE
 OF
 CONSTRUCTION WORKERS. ESCAPE FACILITIES SHALL CONSIST
 OF DOORS,
 WALKWAYS, STAIRS, RAMPS, FIRE ESCAPES, LADDERS, OR
 OTHER APPROVED
 MEANS OR DEVICES ARRANGED IN ACCORDANCE WITH THE
 GENERAL
 PRINCIPLES OF THE CODE INSOFAR AS THEY CAN REASONABLY
 BE APPLIED
 TO BUILDINGS UNDER CONSTRUCTION
  
 PLEASE PROVIDE DETAILS
  
  
 2) SHEET A 108 - THERE ARE NO INDIACTIONS OF EXIT
 HARDWARE, LOCKS OR LATCHES.
  
 PER NFPA 101, CH 12
  
 12.2.2.2 DOORS.
 12.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE
 PERMITTED.
 12.2.2.2.2 ASSEMBLY OCCUPANCIES WITH OCCUPANT LOADS OF
 300 OR LESS IN
 MALLS (SEE 36.4.4.4.2(4) SHALL BE PERMITTED TO HAVE
 HORIZONTAL OR VERTICAL
 SECURITY GRILLES OR DOORS COMPLYING WITH 7.2.1.4.1(3)
 ON THE MAIN
 ENTRANCE/EXITS.
 12.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM
 AN AREA HAVING
 AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE
 PERMITTED TO BE
 PROVIDED WITH A LATCH OR LOCK ONLY IF THE LATCH OR LOCK
 IS PANIC
 HARDWARE OR FIRE EXIT HARDWARE COMPLYING WITH 7.2.1.7,
 UNLESS
 OTHERWISE PERMITTED BY ONE OF THE FOLLOWING:
 (1) THIS REQUIREMENT SHALL NOT APPLY TO DELAYED-EGRESS
 LOCKS AS
 PERMITTED IN 12.2.2.2.5.
 (2) THIS REQUIREMENT SHALL NOT APPLY TO
 ACCESS-CONTROLLED EGRESS DOORS
 AS PERMITTED IN 12.2.2.2.6.
  
 PLEASE PROVIDE DETAILS IN COMPLIANCE OR A DETAILED
 NARRATIVE, INCLUDING MANUFACTURUES'S SPECIFICATION
 SHEETS, WITH SPECIFIC CODE REFERENCES.
  
  
 3) SHEET A 108 & E 1 - HOW WILL THE EXIT AND EXIT
 ACCESS BE MARKED AND ILLUMINATED.
  
 PER NFPA CH 12
  
 12.2.10 MARKING OF MEANS OF EGRESS.
 12.2.10.1 MEANS OF EGRESS SHALL BE PROVIDED WITH SIGNS
 IN
 ACCORDANCE WITH SECTION 7.10.
  
 12.2.8 ILLUMINATION OF MEANS OF EGRESS. MEANS OF
 EGRESS, OTHER HAN FOR PRIVATE PARTY TENTS NOT EXCEEDING
 1200 FT2 (112 M2) , SHALL
 BE ILLUMINATED IN ACCORDANCE WITH SECTION 7.8.
 12.2.9 EMERGENCY LIGHTING.
 12.2.9.1 EMERGENCY LIGHTING SHALL BE PROVIDED IN
 ACCORDANCE WITH
 SECTION 7.9.
  
 PLEASE PROVIDE DETAILS
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-06-17 Time   Rev Time 0.00
Received By lmarchan Date 2020-06-16 Time 07:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-05-21 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-28 Time 13:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-02-25 Time   Rev Time 0.00
Received By lmarchan Date 2020-01-13 Time 12:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-06-16 Cont ID  
Sent By rmcphers Date 2020-06-16 Time 10:28 Rev Time 0.00
Received By rmcphers Date 2020-06-16 Time 10:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-05-20 Cont ID  
Sent By rmcphers Date 2020-05-20 Time 15:25 Rev Time 0.00
Received By rmcphers Date 2020-05-20 Time 15:25 Sent To  
Notes
2020-05-20 15:26:34"ELECTRICAL" DRAWINGS DO NOT SHOW IN "ADOBE" AS
 DIGITALLY SIGNED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-02-14 Cont ID  
Sent By rmcphers Date 2020-02-14 Time 15:05 Rev Time 0.00
Received By rmcphers Date 2020-02-14 Time 14:01 Sent To  
Notes
2020-02-14 15:04:55"SCULPTURAL STRUCTURAL DRAWINGS" AND "ELECTRICAL"
 DRAWINGS DO NOT SHOW IN "ADOBE" AS ELECTRONICALLY
 SIGNED. THIS WILL NEED TO BE CORRECTED.

Review Stop Z ZONING
Rev No 2 Status P Date 2020-05-11 Cont ID  
Sent By eschneid Date 2020-05-11 Time 10:40 Rev Time 0.25
Received By eschneid Date 2020-05-11 Time 10:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-01-28 Cont ID  
Sent By eschneid Date 2020-01-28 Time 14:34 Rev Time 0.75
Received By eschneid Date 2020-01-28 Time 13:10 Sent To  
Notes
2020-01-28 14:34:16FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) PRIOR TO ZONING APPROVAL OF THIS PERMIT. YOU MUST
 SUBMIT A TREE ALTERATION PERMIT TO THE PLANNING
 DIVISION AND IT MUST BE APPROVED.
  
 2) THE LANDSCAPE AND IRRIGATION PLANS ARE BEING REMOVED
 FROM THIS PERMIT SUBMITTAL. SEPARATE PERMITS WITH PLANS
 MUST BE SUBMITTED FOR THE LANDSCAPE AND THE IRRIGATION.
  
 3) THE BUILDING PLANS THEMSELVES MEET THE APPROVED
 MINOR AMENDMENT AND ZONING REQUIREMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]