Plan Review Details - Permit 19120743
Plan Review Stops For Permit 19120743
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2020-01-08 Cont ID  
Sent By dbattles Date 2020-01-08 Time 15:15 Rev Time 0.00
Received By dbattles Date 2020-01-08 Time 15:15 Sent To  
Notes
2020-01-08 15:20:32NO DEMO AND NO STRUCTURAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-01-29 Cont ID  
Sent By dbattles Date 2020-01-29 Time 15:10 Rev Time 0.00
Received By dbattles Date 2020-01-29 Time 15:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-09 Cont ID  
Sent By dbattles Date 2020-01-09 Time 09:56 Rev Time 0.00
Received By dbattles Date 2020-01-08 Time 14:32 Sent To  
Notes
2020-01-09 09:56:53BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19120743
 REVIEWED: JANUARY 9, 2020
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
  
 1) 1004 FBC[B]SHEET A-1 STATES NUMBER OF OCCUPANTS AS
 EXISTING. WHAT WAS THE NUMBER OF OCCUPANTS? THE LAYOUT
 HAS CHANGED WITH THE ADDITION OF A BAR AND PICK UP
 COUNTER. PLEASE RE-CALCULATE THE PROPOSED OCCUPANT LOAD
 AND SHOW ON A-1 DATA.
  
 2) 226.1 FBC[A]IF THERE IS TO BE SEATING AT THE BAR
 PLEASE SHOW ON PLANS.
 ALSO, COMPLY WITH ACCESSIBILITY 226.1.
  
 3) 1006.2.1 FBC[B]PLEASE PROVIDE LIFE SAFTY PLAN TO
 SHOW NUMBER OF EXITS AND COMMON PATH OF TRAVEL.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-01-26 Cont ID  
Sent By jpearson Date 2020-01-26 Time 11:54 Rev Time 0.00
Received By jpearson Date 2020-01-26 Time 11:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-25 Cont ID  
Sent By jpearson Date 2019-12-25 Time 08:19 Rev Time 0.00
Received By jpearson Date 2019-12-25 Time 08:19 Sent To  
Notes
2019-12-25 08:19:42CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL PLANS ARE MISSING A LOT OF INFORMATION, A
 COMPLETE REVIEW IS NOT POSSIBLE AT THIS TIME. PROVIDE
 LEGEND OF SYMBOLS USED ON PLAN. SHOW ALL RECEPTACLE AND
 LIGHTING SWITCHES AND OUTLETS ON PLAN. PROVIDE LIGHT
 FIXTURE SCHEDULE AND INDICATE FIXTURE TYPES ON PLAN.
 WPB FBC 107.2.1
 2. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-01-23 Cont ID  
Sent By pleduc Date 2020-01-23 Time   Rev Time 0.00
Received By pleduc Date 2020-01-23 Time 11:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-12-31 Cont ID  
Sent By pleduc Date 2019-12-31 Time   Rev Time 0.00
Received By pleduc Date 2019-12-31 Time 10:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-01-29 Cont ID  
Sent By dbattles Date 2020-01-29 Time 15:10 Rev Time 0.00
Received By dbattles Date 2020-01-22 Time 11:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-09 Cont ID  
Sent By dbattles Date 2020-01-09 Time 09:56 Rev Time 0.00
Received By dbattles Date 2019-12-24 Time 13:21 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-01-08 Cont ID  
Sent By dbattles Date 2020-01-08 Time 15:14 Rev Time 0.00
Received By dbattles Date 2020-01-08 Time 15:14 Sent To  
Notes
2020-01-08 15:15:25NO CHANGE IN USE AND NO CHANGE IN SQUARE FOOTAGE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2020-01-23 Cont ID  
Sent By ccole Date 2020-01-23 Time 15:55 Rev Time 0.00
Received By ccole Date 2020-01-23 Time 13:39 Sent To  
Notes
2020-01-23 15:56:10SEPARATE PERMIT AND PLANS REQUIRED FOR MECHANICAL.
 CCOLE

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-12-30 Cont ID  
Sent By ccole Date 2019-12-30 Time 14:29 Rev Time 0.00
Received By ccole Date 2019-12-30 Time 14:23 Sent To  
Notes
2019-12-30 14:34:081ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19120743
 12/30/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE MECHANICAL PLANS SHOWING ALL PLANNED
 ALTETRATIONS TO THE EXISTING SYSTEMS- SECTION 107.2.1
 WPB. IF NO MECHANICAL CHANGES OR NEW INSTALLATIONS ARE
 PROPOSED, PLEASE PLACE A NOTE ON THE PLAN.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-01-23 Cont ID  
Sent By jesmith Date 2020-01-23 Time 13:44 Rev Time 0.00
Received By jesmith Date 2020-01-23 Time 13:43 Sent To  
Notes
2020-01-23 13:43:55PLUMBING COMMENTS: APPROVED WITH PROVISO
 PUMP DISCHARGE SHALL NOT CONNECT TO THE FLOOR SINK
 FIXTURE DRAIN IN THE KITCHEN. PER FBC PL 712.3.5, PUMPS
 CONNECTED TO THE DRAINAGE SYSTEM SHALL CONNECT TO A
 BUILDING SEWER, BUILDING DRAIN, SOIL STACK, WASTE STACK
 OR HORIZONTAL BRANCH DRAIN. WHERE THE DISCHARGE LINE
 CONNECTS INTO HORIZONTAL DRAINAGE PIPING, THE
 CONNECTION SHALL BE MADE THROUGH A WYE FITTING INTO THE
 TOP OF THE DRAINAGE PIPING AND SUCH WYE FITTING SHALL
 BE LOCATED NOT LESS THAN 10 PIPE DIAMETERS FROM THE
 BASE OF ANY SOIL STACK, WASTE STACK OR FIXTURE DRAIN.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-01-06 Cont ID  
Sent By tklarge Date 2020-01-06 Time 11:00 Rev Time 0.00
Received By tklarge Date 2020-01-06 Time 05:27 Sent To  
Notes
2020-01-06 10:38:501) SUBMIT AN EXISTING AND PROPOSED FLOOR PLAN FOR
 REVIEW. WPB AMEND. TO FBC SEC. 107.2.1.
 2) SUBMIT A WATER RISER FOR REVIEW. WPB AMEND. TO FBC
 SEC. 107.3.5.1.3.
 3) SUBMIT A COPY OF THE MANUFACTURER'S SPECIFICATIONS
 FOR THE POINT OF USE WATER HEATER.WPB AMEND. TP FBC
 SEC. 107.2.1.
 4) THERE IS A NOTE BY THE VENT FOR THE HANDSINK THAT
 READS "PUMPED 2" TO FLOOR SINK IN KITCHEN". CLARIFY.
 5) IDENTIFY ALL INDIRECT WASTES ON THE SANITARY RISER.
 6) SHT. 3.0P SHOWS 2 FLOOR SINKS ON THE SANITARY RISER
 BUT THE FLOOR PLAN SHOWS 3. CLARIFY.
 7) SIZE THE VENT FOR THE HAND SINK. COMPLY WITH 2017
 FBC-PLUMBING SEC.906.1.
 8) SUBMIT COMPLETE SPECIFICATIONS FOR THE LIBERTY SUMP
 AND PUMP. THE SUMP SHALL COMPLY WITH 2017 FBC-PLUMBING
 SEC.712.3.2.
 9) SIZE THE VENT FOR THE SUMP/PUMP. COMPLY WITH
 MANUFACTURER'S INSTALLATION MANUAL.
 9) THE PUMP CANNOT BE INDIRECTLY WASTED AS SHOWN. THE
 EJECTOR SHALL CONNECT TO THE DRAINAGE SYSTEM IN
 ACCORDANCE WITH 2017 FBC-PLUMBING SEC.712.3.5.
 10) A CHECK VALVE AND A FULL OPEN GATE VALVE ARE
 REQUIRED IN THE PUMP EJECTOR DISCHARGE PIPING PER 2017
 FBC-PLUMBING SEC.712.2.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-01-29 Cont ID  
Sent By dbattles Date 2020-01-29 Time 15:10 Rev Time 0.00
Received By dbattles Date 2020-01-29 Time 15:10 Sent To  
Notes
2020-01-26 11:54:46ELECTRICAL SHEETS OK.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-01-08 Cont ID  
Sent By dbattles Date 2020-01-08 Time 14:39 Rev Time 0.00
Received By dbattles Date 2020-01-08 Time 14:39 Sent To  
Notes
2019-12-25 07:59:05ELECTRICAL SHEETS OK.