Plan Review Details - Permit 19120626
Plan Review Stops For Permit 19120626 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-01-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-01-14 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-01-14 |
Time |
10:00 |
Sent To |
|
|
Notes |
2020-01-14 10:36:36 | THE BUILDING HAS A 15 FT MEAN ROOF HEIGHT AND IS | | LOCATED IN EXPOSURE CATEGORY B. THE ROOF HAS A 3 FOOT | | PARAPET AROUND THE ENTIRE PERIMETER WHICH ALLOWS THE | | NEGATIVE PRESSURES FOR ROOF ZONE 3 TO BE EQUAL TO ZONE | | 2 PER ASCE7-10. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-12-19 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-12-18 |
Time |
12:58 |
Sent To |
|
|
Notes |
2019-12-18 12:59:58 | DISCUSSED WITH KEN CONRAD, CHIEF INSPECTOR. FROM THE | | PHOTOS THAT WERE SUBMITTED, IT APPEARS THAT THE 4'X4' | | INSULATION BOARD WAS ATTACHED TO THE WOOD DECK WITH 4 | | FASTENERS. THE PRODUCT APPROVAL THAT WAS APPROVED BY | | THE CITY REQUIRES ONE FASTENER PER SQUARE FOOT WHICH IS | | 16 FASTENERS FOR A 4'X4' (16 SQFT) ISO BOARD. GAVE ALL | | DOCUMENTS TO K.CONRAD TO MEET WITH CONTRACTOR TO | | RESOLVE THE ISSUE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-12-19 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-12-16 |
Time |
15:24 |
Sent To |
|
|
Notes |
2019-12-19 08:49:06 | NO FEE SUBMITTAL FOR FIELD ISSUE WAS GIVEN TO KEN | | CONRAD. RM | 2019-12-17 15:24:24 | REVISION ROUTED TO RMCDOUGAL |
|
|
|