Plan Review Details - Permit 19111313
Plan Review Stops For Permit 19111313
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2019-12-10 Cont ID  
Sent By jwitmer Date 2019-12-10 Time 15:23 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2019-12-10 15:24:21BUILT IN 1998. NO ASBESTOS. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-01-30 Cont ID  
Sent By pvalenti Date 2020-01-30 Time 10:16 Rev Time 0.00
Received By pvalenti Date 2020-01-30 Time 10:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-01-22 Cont ID  
Sent By pvalenti Date 2020-01-21 Time 12:39 Rev Time 0.00
Received By pvalenti Date 2020-01-21 Time 06:56 Sent To  
Notes
2020-01-21 08:17:06***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 2ND BUILDING REVIEW DENIED:
  
  
  
 1) OK
  
 2) OK
  
 3) FBC BN 2403.2 PROVIDE DETAILED CONSTRUCTION
 DOCUMENTS, SHOP DRAWINGS AND ANALYSIS OR TEST DATA
 ENSURING SAFE PERFORMANCE FOR INSTALLATION OF FRAMELESS
 GLASS SHOWER PANES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-12-10 Cont ID  
Sent By jwitmer Date 2019-12-10 Time 15:23 Rev Time 0.00
Received By jwitmer Date 2019-12-10 Time 14:46 Sent To  
Notes
2019-12-10 15:23:462017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19111313
 ADD: 101 N CLEMATIS ST. SUITE 503
 CONT: ARCH ENTERPRISES INC
 TEL: 561-838-3413
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: DEC. 10/2019
 ACTION: DENIED
  
 1) SHEET 01. BUILDING DATA:
  
 1A) THE PLAN INDICATES THIS IS BUILDING CONSTRUCTION
 TYPE V-B. PLEASE REVIEW THE 2017 FBC-B TABLE II-B FULLY
 SPRINKLERED WITH A NFPA 13 SYSTEM 5 STORY BUILDING.
  
 1B) THE PLAN INDICATES THE OCCUPANCY TYPE AS AN R3
 OCCUPANCY. PLEASE NOTE THIS IS A MID-RISE BUILDING AND
 OCCUPIED BY CONDOMINIUM UNITS. THE OCCUPANCY TYPE IS AN
 R2 PLEASE REVIEW THE 2017 FBC-B SECTION 310.4.
  
 2) THE PLANS ARE SILENT AS TO WHAT TYPE OF FLOOR FINISH
 IS GOING TO BE APPLIED TO THE CONCRETE SLAB. SUBMITTED
 IS A SALES BROCHURE FOR DREAM HOME ECO SILENT FLOOR
 INSULATION. THERE WAS NO TESTING FOR THIS PRODUCT
 SUBMITTED. PLEASE IDENTIFY THE TYPE OF FLOOR FINISH TO
 BE INSTALLED AND SHOW CODE COMPLIANCE BY SUBMITTING THE
 ACTUAL TEST RESULT. SEE THE REQUIREMENTS LISTED BELOW.
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2017)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS (NOT SALES BROCHURES)
 SHOWING COMPLIANCE WITH:
  
 2A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.SHEET
  
 2B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-01-30 Cont ID  
Sent By jpearson Date 2020-01-30 Time 13:57 Rev Time 0.00
Received By jpearson Date 2020-01-30 Time 09:48 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-19 Cont ID  
Sent By jpearson Date 2019-12-19 Time 15:27 Rev Time 0.00
Received By jpearson Date 2019-12-19 Time 06:41 Sent To  
Notes
2019-12-19 15:25:11CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION FOR 1200 AMP
 SERVICE, INCLUDE EXISTING AND NEW LOADS TO CONFIRM
 CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30
 2. IN THE DIAGRAM FOR NEW ELECTRIC, IT APPEARS THAT THE
 WALL SPACING REQUIREMENT FOR RECEPTACLES IS NOT BEING
 MAINTAINED. PROVIDE CLARIFICATION AND/OR CORRECTION.
 NEC 210.52
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-01-17 Cont ID  
Sent By pleduc Date 2020-01-17 Time   Rev Time 0.00
Received By pleduc Date 2020-01-17 Time 11:12 Sent To  
Notes
2020-01-17 11:12:48THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-12-04 Cont ID  
Sent By pleduc Date 2019-12-04 Time   Rev Time 0.00
Received By pleduc Date 2019-12-04 Time 15:14 Sent To  
Notes
2019-12-04 15:15:44THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-04 Cont ID  
Sent By shill Date 2020-01-30 Time 18:29 Rev Time 0.00
Received By jesmith Date 2020-02-04 Time 14:45 Sent To  
Notes
2020-01-14 13:34:53B09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-23 Cont ID  
Sent By gjohnson Date 2019-12-23 Time 15:28 Rev Time 0.00
Received By gjohnson Date 2019-11-26 Time 13:04 Sent To  
Notes
2019-11-27 13:04:43B09

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-01-21 Cont ID  
Sent By ccole Date 2020-01-21 Time 14:52 Rev Time 0.00
Received By ccole Date 2020-01-21 Time 14:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-12-23 Cont ID  
Sent By ccole Date 2019-12-23 Time 08:44 Rev Time 0.00
Received By ccole Date 2019-12-20 Time 11:46 Sent To  
Notes
2019-12-23 08:47:331ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19111313
 12/23/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 01: NOTE #4 CALLS OUT AC ALTERATIONS AND
 CALCULATIONS- PLEASE SUBMIT MECHANICAL PLANS- SECTION
 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-02-04 Cont ID  
Sent By jesmith Date 2020-01-16 Time 15:33 Rev Time 0.00
Received By jesmith Date 2020-01-16 Time 15:08 Sent To  
Notes
2020-01-16 15:33:06PLUMBING: APPROVED W/PROVISO
 PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE AS A
 DEFERRED SUBMITTAL, REVISED PLANS INDICATING THE
 LOCATION OF THE WASHER; INDICATE ON THE RISER DIAGRAMS
 WHERE CONNECTIONS ARE MADE. ADDITIONALLY, INDICATE ON
 THE SANITARY RISER DIAGRAM WHERE THE EXISTING HALF BATH
 CONNECTS. PLANS SHALL BE SUBMITTED, APPROVED AND ON
 SITE PRIOR TO FINAL INSPECTION. PROCEED AT YOUR OWN
 RISK.
  
  
 19111313 101 N CLEMATIS ST 503
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-12-23 Cont ID  
Sent By gjohnson Date 2019-12-23 Time 15:28 Rev Time 0.00
Received By gjohnson Date 2019-12-23 Time 15:28 Sent To  
Notes
2019-12-23 15:28:381ST REVIEW 19111313
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 FBC PL = FLORIDA BUILDING CODE PLUMBING 2017 6TH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THIS RESIDENTIAL UNIT WAS BUILT IN COMPLIANCE WITH
 THE FAIR HOUSING ACT AND IS REQUIRED TO STAY IN
 COMPLIANCE PLEASE INDICATE ON THE PLAN THE DESIGN SPEC
 THE BATHROOM IS BEING DESIGNED TO A OR BEACH
 SHOW THE CLEAR FLOOR SPACE FOR THE TOILET SHOWER AND
 LAVATORY AND THE HIGHT OF THE LAVATORY VANITY AND THE
 BACKING FOR GRAB BARS PER THE FAIR HOUSING ACT DESIGN
 MANUAL REQUIREMENTS 6+7 PGS. 6.3-6.7, 7.35, 7.43, 7.47,
 7.56 IF THE UNIT IS NOT BEING DESIGNED IN COMPLIANCE TO
 FAIR HOUSING PROVIDE A LETTER FROM THE DESIGNER OF
 RECORD AND THE UNIT OWNER ACKNOWLEDGING THAT FACT AND
 STATING THAT IF THE UNIT IS SOLD IT IS THE
 RESPONSIBILITY OF THE OWNER TO BRING THE UNIT BACK INTO
 COMPLIANCE.
  
 2. THE STUDOR VENTS SHALL NOT BE USED BELOW THE 4TH
 BRANCH INTERVAL OF THE SANITARY STACK BELOW THE TOP OF
 THE STACK. PER FBC PL 918.3.1
  
 3. PROVIDE A WATER ISOMETRIC. PER WPB AMEND TO FBC
 107.3.5.1.3(13)
  
 4. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTILLATION
 GUIDE FOR TANKLESS WATER HEATER. PER WPB AMEND TO FBC
 107.2.1
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  