Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-03-16 Cont ID  
Sent By rmcphers Date 2020-03-16 Time 13:01 Rev Time 0.00
Received By rmcphers Date 2020-03-16 Time 12:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-01-21 Cont ID  
Sent By shill Date 2020-01-21 Time 10:22 Rev Time 0.00
Received By shill Date 2020-01-21 Time 10:22 Sent To  
Notes
2020-01-21 10:23:09****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. A STRUCTURAL PAGE (A001) WAS SUBMITTED WITHOUT A
 TITLE BLOCK. A SIMILAR PAGE, BUT WITH THE ENGINEER'S
 SEAL AND SIGNATURE AND TITLE BLOCK, WAS UPLOADED TO THE
 SIGNATURE FOLDER. AS THE DRAWINGS FOLDE PLAN PAGES ARE
 THE PERMIT RECORD DOCUMENTS, AND THE STRUCTURAL PAGE
 LACKS INFORMATION REGARDING WHO IS RESPONSIBLE FOR THE
 INFORMATION, PLEASE PROVIDE THE PAGE WITH THE
 ENGINEER'S INFORMATION IN THE DRAWINGS FOLDER.
  
 THE PAGE IN THE SIGNATURE FOLDER IS NOT THE SAME AS THE
 PAGE IN THE DRAWINGS FOLDER. UPLOAD A DIGITALLY SIGNED
 PAGE A001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 15:19 Rev Time 0.00
Received By shill Date 2019-12-18 Time 15:19 Sent To  
Notes
2019-12-18 15:24:49****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. A STRUCTURAL PAGE (A001) WAS SUBMITTED WITHOUT A
 TITLE BLOCK. A SIMILAR PAGE, BUT WITH THE ENGINEER'S
 SEAL AND SIGNATURE AND TITLE BLOCK, WAS UPLOADED TO THE
 SIGNATURE FOLDER. AS THE DRAWINGS FOLDE PLAN PAGES ARE
 THE PERMIT RECORD DOCUMENTS, AND THE STRUCTURAL PAGE
 LACKS INFORMATION REGARDING WHO IS RESPONSIBLE FOR THE
 INFORMATION, PLEASE PROVIDE THE PAGE WITH THE
 ENGINEER'S INFORMATION IN THE DRAWINGS FOLDER.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-18 Cont ID  
Sent By jleahy Date 2019-12-18 Time 09:57 Rev Time 0.00
Received By jleahy Date 2019-12-18 Time 09:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-12 Cont ID  
Sent By jleahy Date 2019-12-12 Time 13:58 Rev Time 0.00
Received By jleahy Date 2019-12-12 Time 13:58 Sent To  
Notes
2019-12-12 14:00:35FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 VALUE FOR WORK IS FOR LABOR ONLY NEED TO SUBMIT VALUE
 OF THE SIGN.
  
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-16 Cont ID  
Sent By lmarchan Date 2020-03-16 Time 14:22 Rev Time 0.00
Received By lmarchan Date 2020-03-12 Time 09:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-01-21 Cont ID  
Sent By shill Date 2020-01-21 Time 10:28 Rev Time 0.00
Received By shill Date 2019-12-24 Time 08:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 15:28 Rev Time 0.00
Received By shill Date 2019-11-21 Time 10:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-03-16 Cont ID  
Sent By rmcphers Date 2020-03-16 Time 13:01 Rev Time 0.00
Received By rmcphers Date 2020-03-16 Time 13:01 Sent To  
Notes
2020-03-16 13:02:36SIGNED PLANS ARE IN "SIGNATURES" FOLDER

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-01-21 Cont ID  
Sent By shill Date 2020-01-21 Time 10:28 Rev Time 0.00
Received By shill Date 2020-01-21 Time 10:28 Sent To  
Notes
2020-01-21 10:28:19SEE BUILDING REVIEW
  
2019-12-24 08:08:21NEW DIGITALLY SIGNED SET OF PLANS IN "SIGNATURES"

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 15:28 Rev Time 0.00
Received By shill Date 2019-12-18 Time 15:28 Sent To  
Notes
2019-12-18 15:28:38SEE BUILDING REVIEW
  

Review Stop Z ZONING
Rev No 3 Status P Date 2020-03-16 Cont ID  
Sent By jroach Date 2020-03-16 Time 14:10 Rev Time 0.00
Received By jroach Date 2020-03-16 Time 14:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2019-12-18 Cont ID  
Sent By jroach Date 2019-12-18 Time 08:56 Rev Time 0.00
Received By jroach Date 2019-12-18 Time 08:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-11-25 Cont ID  
Sent By jroach Date 2019-11-25 Time 09:37 Rev Time 0.00
Received By jroach Date 2019-11-25 Time 09:24 Sent To  
Notes
2019-11-25 09:37:17ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 11.25.2019
 PERMIT NO.: 19110964
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PLANS SUBMITTED INDICATE THAT THE TENANT SPACE HAS A
 FRONTAGE OF 64 FEET, WHICH IS INCORRECT. BASED UPON THE
 INTERIOR BUILD-OUT PLAN, THE SPACE IS ONLY 29?6? IN
 WIDTH.
  
 2. THE PLANS DID NOT PROVIDE THE DIMENSIONS OF THE
 LETTERS. AS REQUIRED BY THE HOME DEPOT COMMERCIAL
 PLANNED DEVELOPMENT, INDIVIDUAL LETTERS ARE NOT TO
 EXCEED 30? IN HEIGHT.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved