Plan Review Details - Permit 19110914
Plan Review Stops For Permit 19110914 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-01-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-01-24 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-01-24 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-01-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-01-02 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-01-02 |
Time |
14:46 |
Sent To |
|
|
Notes |
2020-01-02 16:12:44 | PLAN REVIEW - BUILDING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. REMOVE ANY PLANS MARKED VOID FROM SUBMITTAL. | | | | 2. REMOVE ANY PLANS MARKED SUPERCEDED BY NEW PAGE A-1. | | | | 3. PLANS SHALL EITHER BE SIGNED AND SEALED BY A DESIGN | | PROFESSIONAL OR CONTRACTORS SHALL PRINT THEIR | | NAME/LICENSE NUMBER AND SIGN PLAN. | | | | 4. PROVIDE TWO COMPLETE SETS OF PLANS FOR REVIEW. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-11-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-11-26 |
Time |
07:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-11-26 |
Time |
07:48 |
Sent To |
|
|
Notes |
2019-11-26 07:53:40 | PLAN REVIEW - BUILDING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW 30 INCH EXTERIOR | | DOOR. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | 2. PROVIDE DESIGN PRESSURES FOR NEW OPENING. | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | | | 3. PROVIDE FRAMING DETAIL FOR EXTERIOR WALL AT EXTERIOR | | DOOR TO BE REMOVED. INCLUDE WALL TYPE, FRAMING AND | | CLADDING MATERIALS AND CONNECTOR SCHEDULE. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-01-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-01-24 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-01-24 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-12-26 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-12-26 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-12-26 |
Time |
09:36 |
Sent To |
|
|
Notes |
2019-12-26 09:36:14 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED(AND | | SEALED WHERE APPLICABLE) BY THE PERSON RESPONSIBLE FOR | | THE DESIGN. WPB FBC 107.2.1, 107.3.5; FS 471, 481 (EACH | | SHEET SUBMITTED MUST BE SIGNED BY THE PERSON | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION.) | | | | NEW COMMENTS: | | | | 2. A LOAD CALCULATION WAS PROVIDED THAT WAS SIGNED BY | | THE ELECTRICAL CONTRACTOR. THIS LOAD CALCULATION IS NOT | | PER CODE. HOWEVER, IF THERE IS NO LOAD BEING ADDED, A | | LOAD CALCULATION IS NOT REQUIRED. IS THERE ANY LOAD | | BEING ADDED? IF LOAD IS BEING ADDED, OR THE SERVICE IS | | BEING UPGRADED, THEN PROVIDE ACURATE LOAD CALCULATION | | PER METHOD DETAILED IN THE FBC RESIDENTIAL. NEC 215.2, | | 220, 408.30; FBC RE E3602.2 | | 3. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | ALARMS, OR PROVIDE A NOTE REQUIRING COMPLIANCE. IF NONE | | ARE EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. | | FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | 210.8(D); FBC RE E3902.10 | | 6. REMOVE ANY VOIDED SHEETS FROM PACKAGE. WPB FBC | | 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-11-21 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-11-21 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-11-21 |
Time |
09:37 |
Sent To |
|
|
Notes |
2019-11-21 09:36:59 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED(AND | | SEALED WHERE APPLICABLE) BY THE PERSON RESPONSIBLE FOR | | THE DESIGN. WPB FBC 107.2.1, 107.3.5; FS 471, 481 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-01-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-01-24 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-01-24 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-01-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-01-02 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-12-20 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-11-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-11-26 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-11-19 |
Time |
13:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2020-01-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-01-24 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-01-24 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-01-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-01-02 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-01-02 |
Time |
14:46 |
Sent To |
|
|
Notes |
2020-01-02 16:15:52 | PLAN REVIEW - PLUMBING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PLANS SHALL EITHER BE SIGNED AND SEALED BY A DESIGN | | PROFESSIONAL OR THE PLUMBING CONTRACTOR SHALL PRINT HIS | | NAME/LIC NUMBER AND SIGN PLAN. | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-11-26 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-11-26 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-11-26 |
Time |
06:43 |
Sent To |
|
|
Notes |
2019-11-26 06:44:31 | 11/26/2019 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. THE PLAN IS TOO SMALL TO READ NOTES, PLANS SHALL BE | | DRAWN TO A MINIMUM 1/8" INCH SCALE PER THE WPB | | AMENDMENT TO FBC SEC. 107.2.1.3 QUALITY OF BUILDING | | PLANS. | | 2. THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL | | FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING | | DIMENSIONS; AND ALL EXTERIOR ELEVATIONS IF APPLICABLE | | PER THE FBC WPB AMENDMENTS SEC. 107.3.5 MINIMUM PLAN | | REVIEW CRITERIA FOR BUILDINGS. | | 3. SIGNATURE (OR SEAL, OR TITLE BLOCK, OR ALL THREE) | | ARE NOT IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE | | 61G15-23.001, FLORIDA STATUTE 471. WPB AMENDMENTS TO | | THE FBC SEC. 107.1 GENERAL. | | 4. THE EXISTING PLAN ARE NOT CLEAR OF WHAT IS TO BE | | DONE. DRAWING INDEX HAS SHEET 1.4 AND 1.5 ELEVATION BUT | | THERE ARE NOT IN SET OF PLANS, PLEASE PROVIDE OR DELETE | | FROM INDEX PER THE WPB AMENDMENTS TO THE FBC SEC. 107.1 | | GENERAL. | | 5. ON THE SCOPE OF WORK, IT SAYS ALTER BATHROOM TO | | INCLUDE WASHING MACHINE, BUT THE MASTER IS LABELED AS | | FUTURE ON SHEET 1.1 AND ON PLUMBING SHEET 1.2 THE 1/2 | | BATH IN NOT SHOWN PLEASE CLARIFY PER THE WPB AMENDMENTS | | TO THE FBC SEC. 107.1 GENERAL. | | 6. ISOMETRIC DRAWING WHICH WAS SUBMITTED DOES NOT SHOW | | THE MASTER THAT IS LABELED AS FUTURE, IS IT PART OF THE | | SCOPE AND IF IT IS PLEASE INCORPORATE IT IN THE | | ISOMETRIC DRAWING. THE KITCHEN CAN NOT BE UP STREAM OF | | A BATHROOM GROUP AND THE WASHING MACHINE CAN NOT BE AN | | AAV ON 2" INCH, THE STANDPIPE HAS TO BE A 3" INCH | | MINIMUM ACCORDING TO AAV MANUFACTURES SPECIFICATION. | | W/M NEEDS TO BE DOWN STREAM OF THE BATHROOM GROUP AS | | WELL AND YOU CAN COMBINE WITH K/S, PLEASE MAKE CHANGES | | AS RESUBMIT WITH CLARITY PER THE WPB AMENDMENTS TO THE | | FBC SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING. | | 7. YOU ARE WELCOME TO CONTACT ME TO DISCUSS THIS REVIEW | | AND GO OVER CORRECTION. I AM AVAILABLE AS NOTED BELOW. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM | | [email protected] | | 561-701-6437 | | |
|
|
|