Plan Review Details - Permit 19110738
Plan Review Stops For Permit 19110738
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-12-02 Cont ID  
Sent By rmcdouga Date 2019-12-02 Time 17:17 Rev Time 0.00
Received By rmcdouga Date 2019-12-02 Time 17:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-11-18 Cont ID  
Sent By rmcdouga Date 2019-11-18 Time 18:59 Rev Time 0.00
Received By rmcdouga Date 2019-11-18 Time 18:59 Sent To I
Notes
2019-11-18 18:59:25PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 REVISION DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SYSTEM NUMBER W-2 ON PAGE 2 OF 3 OF PRODUCT
 APPROVAL FL9487-R5 FOR WOOD DECKS WITH MECHANICALLY
 ATTACHED INSULATION AND BONDED ROOF COVER HAS A MAXIMUM
 DESIGN PRESSURE OF -82.5 PSF. THIS TWO STORY BUILDING
 IS LOCATED IN EXPOSURE CATEGORY C WITH A VULT WIND
 SPEED OF 170 MPH. THE UPLIFT FOR ROOF ZONE 3 (CORNERS)
 IS -102 PSF AND EXCEEDS THE MAXIMUM DESIGN PRESSURE OF
 THE SPECIFIED SYSTEM.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-02 Cont ID  
Sent By rmcdouga Date 2019-12-02 Time 17:17 Rev Time 0.00
Received By rmcdouga Date 2019-11-22 Time 14:49 Sent To  
Notes
2019-11-25 14:49:40RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-18 Cont ID  
Sent By rmcdouga Date 2019-11-18 Time 18:59 Rev Time 0.00
Received By rmcdouga Date 2019-11-15 Time 15:31 Sent To  
Notes
2019-11-18 15:31:19REVISION ROUTED TO RMCDOUGAL