Plan Review Details - Permit 19110642
Plan Review Stops For Permit 19110642
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-01-07 Cont ID  
Sent By dbattles Date 2020-01-07 Time 14:19 Rev Time 0.00
Received By dbattles Date 2020-01-07 Time 14:19 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-01-02 Cont ID  
Sent By dbattles Date 2020-01-02 Time 13:05 Rev Time 0.00
Received By dbattles Date 2020-01-02 Time 07:45 Sent To  
Notes
2020-01-02 13:08:03PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: HTTP://PALM
 BEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICES/ENVIRONME
 NTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-RENOVATION.
 HTML. THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA
 EMAIL TO [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT
 LINE.
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-01-07 Cont ID  
Sent By dbattles Date 2020-01-07 Time 14:19 Rev Time 0.00
Received By dbattles Date 2020-01-07 Time 14:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-02 Cont ID  
Sent By dbattles Date 2020-01-02 Time 13:08 Rev Time 0.00
Received By dbattles Date 2020-01-02 Time 07:45 Sent To  
Notes
2020-01-02 13:08:38BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19110642
 REVIEWED: JANUARY 2, 2020
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
  
 308.3.2 FBC[A]OBSTRUCTED HIGH REACH. WHERE A CLEAR
 FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN
 ELEMENT AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION,
 THE HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES (865
 MM) MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE
 24 INCHES (610 MM) MAXIMUM. THE HIGH SIDE REACH SHALL
 BE 48 INCHES (1220 MM) MAXIMUM FOR A REACH DEPTH OF 10
 INCHES (255 MM) MAXIMUM. WHERE THE REACH DEPTH EXCEEDS
 10 INCHES (255 MM), THE HIGH SIDE REACH SHALL BE 46
 INCHES (1170 MM) MAXIMUM FOR A REACH DEPTH OF 24 INCHES
 (610 MM) MAXIMUM.
 -PLEASE REVIEW REACH RANGE FOR MICROWAVE IN THE KITCHEN
 UPPER CABINETS.
 HOW WOULD THE CURRENT LAYOUT MEET 308.3.3 AND 309?
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-12-17 Cont ID  
Sent By jleahy Date 2019-12-17 Time 11:57 Rev Time 0.00
Received By jleahy Date 2019-12-17 Time 11:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-11-18 Cont ID  
Sent By pleduc Date 2019-11-18 Time   Rev Time 0.00
Received By pleduc Date 2019-11-18 Time 15:58 Sent To  
Notes
2019-11-18 16:01:09THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO AND CONSTRUCTION.
  
  
 2) ANY WORK ON THE FS & FA SYSTEMS SHALL BE DONE UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS.
  
  
 3) ACCESS CONTROL SHALL BE SUBMITTED UNDER SEPARATE
 PERMIT AND COMPLY WITH NFPA 101, CH 7 MEANS OF EGRESS
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-01-16 Cont ID  
Sent By lmarchan Date 2020-01-16 Time 12:17 Rev Time 0.00
Received By lmarchan Date 2020-01-07 Time 10:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-02 Cont ID  
Sent By dbattles Date 2020-01-02 Time 13:10 Rev Time 0.00
Received By dbattles Date 2019-11-13 Time 16:07 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-01-02 Cont ID  
Sent By dbattles Date 2020-01-02 Time 13:10 Rev Time 0.00
Received By dbattles Date 2020-01-02 Time 07:45 Sent To  
Notes
2020-01-02 13:11:26NO CHANGE IN OCCUPANCY AND NO ADDITIONAL SQ. FOOTAGE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-12-24 Cont ID  
Sent By ccole Date 2019-12-23 Time 07:41 Rev Time 0.00
Received By ccole Date 2019-12-23 Time 16:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-01-16 Cont ID  
Sent By tklarge Date 2020-01-16 Time 10:07 Rev Time 0.00
Received By tklarge Date 2020-01-16 Time 06:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-12-20 Cont ID  
Sent By gjohnson Date 2019-12-20 Time 13:21 Rev Time 0.00
Received By gjohnson Date 2019-12-20 Time 11:19 Sent To  
Notes
2019-12-20 13:55:021ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE SHOW THE FOLLOWING ACCESSIBILITY REQUIREMENTS
 PER FBC ACC
  
 602.2 CLEAR FLOOR SPACE. UNITS SHALL HAVE A CLEAR FLOOR
 OR GROUND SPACE COMPLYING WITH 305 POSITIONED FOR A
 FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE
 CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED.
  
 602.4 SPOUT HEIGHT. SPOUT OUTLETS SHALL BE 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. SPOUT
 OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS
 SHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR OR GROUND.
  
 604.2 LOCATION.THE WATER CLOSET SHALL BE POSITIONED
 WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE.
 THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES
 MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR
 PARTITION
  
 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE
 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM
 THE REAR WALL.
  
 604.4 SEATS. THE SEAT HEIGHT OF A WATER CLOSET ABOVE
 THE FINISH FLOOR SHALL BE 17 INCHES MINIMUM AND 19
 INCHES MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS
 SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION.
  
 604.5.1 SIDE WALL. THE SIDE WALL GRAB BAR SHALL BE 42
 INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE
 REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR
 WALL.
  
 604.5.2 REAR WALL.THE REAR WALL GRAB BAR SHALL BE 36
 INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF
 THE WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24
 INCHES MINIMUM ON THE OTHER SIDE.
  
 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE
 INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM
 AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED
 TO THE TOP OF THE GRIPPING SURFACE
  
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-01-07 Cont ID  
Sent By dbattles Date 2020-01-07 Time 14:20 Rev Time 0.00
Received By dbattles Date 2020-01-07 Time 14:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-01-02 Cont ID  
Sent By dbattles Date 2020-01-02 Time 13:03 Rev Time 0.00
Received By dbattles Date 2020-01-02 Time 13:03 Sent To  
Notes
2020-01-02 13:04:26ALL SHEETS OK FOR FIRST REVIEW.
  
 ANY ADDITIONAL SHEETS PROVIDED FOR COMMENT RESPONSE
 WILL NEED TO BE DIGITALLY SIGNED.