Plan Review Details - Permit 19110257
Plan Review Stops For Permit 19110257
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2020-01-07 Cont ID  
Sent By cpuell Date 2020-01-07 Time 11:26 Rev Time 0.00
Received By cpuell Date 2020-01-07 Time 11:26 Sent To  
Notes
2020-01-07 11:27:18ADDRESS CREATED 1/7/19

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 15:44 Rev Time 0.00
Received By shill Date 2019-12-18 Time 15:43 Sent To  
Notes
2019-12-18 15:44:23FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL):
  
 MICHAEL ORIO
 GIS SUPPORT SPECIALIST
 [email protected]
 CITY OF WEST PALM BEACH
 INFORMATION TECHNOLOGY DEPARTMENT
 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401
 P: 561.494.1080
  
 AFTER AN ADDRESS HAS BEEN ASSIGNED, OR IF IT IS
 CONFIRMED THAT THE ADDRESS WILL REMAIN THE SAME, PLEASE
 FORWARD MR. ORIO'S EMAIL TO [email protected].
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-12-18 Cont ID  
Sent By rmcphers Date 2020-12-18 Time 10:18 Rev Time 0.00
Received By rmcphers Date 2020-12-18 Time 10:11 Sent To  
Notes
2020-12-18 10:18:40PRIVISO - NEED ORIGINAL SIGNED AND SEALED DRAWINGS OR
 ELECTRONICALLY/DIGITALLY SIGNED DRAWINGS FOR DRAWINGS
 IN PROJECTDOX MARKED - "RAMPS AND STEPS", "SURVEY",
 "FOUNDATION PLAN", "AE101" AND "S001"

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-12-17 Cont ID  
Sent By jwitmer Date 2019-12-17 Time 08:14 Rev Time 0.00
Received By jwitmer Date 2019-12-16 Time 15:10 Sent To  
Notes
2019-12-17 08:14:432017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19110257
 ADD: 5015 ROEBUCK RD.
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-494-1091
 E-MAIL: KCVOLBRECHT
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. DEC. 17/ 2019
 ACTION: DENIED
  
 1) ARCHITECTURAL SHEETS 26 OF 35 AND 27 OF 35 NEITHER
 SHOW THEY HAVE AN ELECTRONIC SIGNATURE. ARCHITECT
 DIGITAL SIGNING & SEALING PLANS. 61G1-16.005 PROCEDURES
 FOR DIGITALLY SIGNING AND SEALING AND FOR
 ELECTRONICALLY TRANSMITTING PLANS, SPECIFICATIONS,
 REPORTS OR OTHER DOCUMENTS.
  
 2) SHEET 26 OF 35 SPECIAL NOTE 2 REQUIRES A FIRE
 SPRINKLER SYSTEM. IN THE 2017 FBC-B SECTIONS 420.6 AND
 903.2.8. THERE WERE NO PLANS SUBMITTED IN THIS PACKAGE.
  
 3) SHEET 26 OF 35 INDICATE WITH GENERAL NOTE D THAT THE
 EXISTING FRAME AND FABRIC AWNING ARE TO BE DEMOLISHED.
 IT APPEARS THEY ARE BEING REUSED AND THERE IS NOT
 ENOUGH INFORMATION. SHEET 34 IS A STRUCTURAL SHEET FOR
 THE LAYOUT OF THE CANOPY FOR THE FOUNDATION, WIND
 DESIGN CRITERIA IS GIVEN ON THE STRUCTURAL SHEET 33 BUT
 THERE IS NO SIZE OF THE STRUCTURAL MEMBERS, THERE IS A
 NOTE STATING THAT THE CANOPY FRAME IS STEEL BUT NO
 OTHER INFORMATION ON THE STEEL FRAMING MEMBERS NOR THE
 REQUIRED WELD INFO TO ASSEMBLE THE USED STEEL FRAME.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
 WELDED OR BOLTED CONNECTIONS
 THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION. IN ACCORDANCE WITH THE
 AMERICAN WELDING SOCIETY.
 2017 FBC-B 2204.1 WELDING
 2017 FBC-B 2204.2 BOLTING.
 IF THERE IS ANY QUESTIONS ABOUT THE CODE REQUIREMENTS
 FOR THIS SECTION, PLEASE CONTACT THE CHIEF BUILDING
 INSPECTOR KEN CONRAD AT 561-805-6666. THANK YOU.
  
 4) ARCHITECTURAL SHEET 26 OF 28 GENERAL NOTE E STATES
 SEE AE101 AND AE 201 FOR ADDITIONAL INFORMATION ON THE
 EXISTING TRAILER PLANS AND ELEVATIONS. ALSO SEE AE101
 FOR THE PLAN OF NEW ALUMINUM WALKWAY COVER. THESE PLANS
 WERE NOT PART OF THIS SUBMITTAL PACKAGE. 107.2.1.2.
 ADDITIONAL INFORMATION IS REQUIRED.
  
 5) WITHIN THIS PERMIT PACKAGE SUBMITTAL THERE WAS NO
 ENGINEERING FOR THE TIE DOWN INFORMATION FOR THE 180
 MILES PER HOUR WIND DESIGN. 107.2.1.2 ADDITIONAL
 INFORMATION IS REQUIRED. 2017 FBC-B 1604.4 ANALYSIS.
 LOAD EFFECTS ON STRUCTURAL MEMBERS AND THEIR
 CONNECTIONS SHALL BE DETERMINED BY METHODS OF
 STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT EQUILIBRIUM,
 GENERAL STABILITY, GEOMETRIC COMPATIBILITY AND BOTH
 SHORT- AND LONG-TERM MATERIAL PROPERTIES. EVERY
 STRUCTURE SHALL BE DESIGNED TO RESIST THE OVERTURNING
 EFFECTS CAUSED BY THE LATERAL FORCES SPECIFIED IN THIS
 CHAPTER. SEE SECTION 1609 FOR WIND LOADS.
 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-04-14 Cont ID  
Sent By jleahy Date 2020-04-14 Time 09:34 Rev Time 0.00
Received By jleahy Date 2020-04-14 Time 09:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-16 Cont ID  
Sent By jleahy Date 2019-12-16 Time 08:56 Rev Time 0.00
Received By jleahy Date 2019-12-16 Time 08:56 Sent To  
Notes
2019-12-16 09:03:18FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E.201
  
 1) NOTE #8 200A DISCONNECT OR A 150A DISCONNECT???
  
 2) 250.94 INTERSYSTEM BONDING STRIP REQUIRED.
  
 3) OUTLET REQIIRED AT SERVICE RACK 210.64
  
 4) PANELS IN TRAILERS ARE ONLY RATED FOR 125A. OCP
 CANNOT BE HIGHER THAN 125A.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2020-12-16 Cont ID  
Sent By rrossano Date 2020-12-16 Time   Rev Time 0.00
Received By rrossano Date 2020-12-16 Time   Sent To  
Notes
2020-12-16 09:58:30REVIEWED UNDER ENGINEERING SUBMITTAL E19100037.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 15:44 Rev Time 0.00
Received By shill Date 2019-12-18 Time 15:44 Sent To  
Notes
2019-12-18 15:44:58CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  
 IF YOU HAVE AN ISSUED ENGINEERING PERMIT, OR A PENDING
 APPLICATION, PLEASE ADVISE VIA EMAIL ([email protected])
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-11-15 Cont ID  
Sent By pleduc Date 2019-11-15 Time   Rev Time 0.00
Received By pleduc Date 2019-11-15 Time 13:25 Sent To  
Notes
2019-11-15 13:26:55THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) EXISTING FIRE SPRINKLER AND FIRE ALARM SYSTEMS
 REQUIRE SEPARATE PERMITS AND SHOP DRAWINGS TO ENSURE
 PROPER TESTING AND FUNCTIONALITY PER THE APPLICABLE
 CODES.
  
  
 2) UNDERGROUND FIRE LINE SHALL BE UNDER SEPRARTE PERMIT
 AND SHOP DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-21 Cont ID  
Sent By ajones Date 2020-12-21 Time 09:51 Rev Time 0.00
Received By ajones Date 2020-12-17 Time 12:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-27 Cont ID  
Sent By lmarchan Date 2019-12-27 Time 11:10 Rev Time 0.00
Received By lmarchan Date 2019-11-08 Time 16:16 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-12-17 Cont ID  
Sent By jwitmer Date 2019-12-17 Time 08:14 Rev Time 0.00
Received By jwitmer Date 2019-12-16 Time 15:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2019-12-17 Cont ID  
Sent By ccole Date 2019-12-16 Time 17:31 Rev Time 0.00
Received By ccole Date 2019-12-16 Time 17:19 Sent To  
Notes
2019-12-17 07:38:35SEPARATE PERMITS REQUIRED FOR ON-SITE MECHANICAL WORK
 INCLUDING, BUT NOT LIMITED TO,
 KITCHEN EXHAUST HOODS AND FORE SUPPRESSION SYSTEMS.
2019-12-16 17:52:38 
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-12-19 Cont ID  
Sent By gjohnson Date 2019-12-19 Time 10:08 Rev Time 0.00
Received By gjohnson Date 2019-12-19 Time 08:33 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2020-12-18 Cont ID  
Sent By rmcphers Date 2020-12-18 Time 10:19 Rev Time 0.00
Received By rmcphers Date 2020-12-18 Time 10:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 16:02 Rev Time 0.00
Received By shill Date 2019-12-16 Time 15:10 Sent To  
Notes
2019-12-18 16:02:59SEE BUILDING REVIEW
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-12-18 Cont ID  
Sent By rmcphers Date 2020-12-18 Time 10:20 Rev Time 0.00
Received By rmcphers Date 2020-12-18 Time 10:20 Sent To  
Notes
2020-12-18 10:21:03PRIVISO - NEED ORIGINAL SIGNED AND SEALED DRAWINGS OR
 ELECTRONICALLY/DIGITALLY SIGNED DRAWINGS FOR DRAWINGS
 IN PROJECTDOX MARKED - "RAMPS AND STEPS", "SURVEY",
 "FOUNDATION PLAN", "AE101" AND "S001"

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-12-18 Cont ID  
Sent By shill Date 2019-12-18 Time 16:02 Rev Time 0.00
Received By shill Date 2019-12-18 Time 15:45 Sent To  
Notes
2019-12-18 15:51:07****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
  
 1. PAGES WERE NOT NAMED AND UPLOADED CORRECTLY. PLEASE
 SEE THE GUIDELINES IN THE PROJECTDOX QUICKSTART GUIDE,
 AVAILABLE ON OUR WEBSITE. (GOOGLE CITY OF WEST PALM
 BEACH ELECTRONIC PLAN REVIEW). CONTACT
 [email protected] TO COORDINATE; IT APPEARS THAT
 ALL DOCUMENTS WILL NEED TO BE DELETED AND UPLOADED
 CORRECTLY.
  
 APPLICATION STATES THAT THIS IS A MODULAR BUILDING.
 MODULAR PLANS WHICH HAVE ALREADY BEEN REVIEWED AND ARE
 ON FILE WITH THE STATE OF FLORIDA SHOULD NOT BE
 UPLOADED AS PLAN PAGES, BUT ARE TREATED LIKE PRODUCT
 APPROVALS (UPLOADED INTO THE SUPPORTING DOCUMENTS
 FOLDER).
  
 2. SURVEY IS NOT DIGITALLY SIGNED. EITHER PROVIDE A
 DIGITALLY SIGNED SURVEY OR ONE PAPER ORIGINAL WILL BE
 REQURIED TO BE SUBMITTED PRIOR TO ISSUANCE.
  
 3. SURVEY WAS UPLOADED AS A MULTIPAGE PDF INTO THE
 DRAWINGS FOLDER; NEEDS TO BE INDIVIDUAL PAGES NAMED
 CORRECTLY.
  
 4. LANDSCAPE PAGES HAVE BEEN REMOVED. SUBMIT LANDSCAPE
 PLANS UNDER SEPARATE PERMIT. WAS LANDSCAPE VALUE
 INCLUDED IN THE VALUE FOR THE PROJECT? IF YES, THIS
 NEEDS TO BE REMOVED. PLEASE EMAIL ME FOR FURTHER
 GUIDANCE.
  
 5. DIGITAL SIGNATURES ARE OK.
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-12-21 Cont ID  
Sent By ajones Date 2020-12-21 Time 09:51 Rev Time 0.00
Received By ajones Date 2020-12-21 Time 09:50 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-12-19 Cont ID  
Sent By cglass Date 2019-12-19 Time 12:54 Rev Time 0.00
Received By cdglass Date 2019-12-19 Time 12:54 Sent To  
Notes
2019-12-19 12:56:06PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON THE
 PROPERTY, A TREE ALTERATION PERMIT SHALL BE SUBMITTED,
 REVIEWED, AND APPROVED BY THE PLANNING DIVISION. PLEASE
 SUBMIT APPROPRIATE LANDSCAPE PERMITS.
  
 CAROLINE GLASS
 GIS PLANNER
 [email protected]


Account Summary | Usage Policy | Privacy Policy