Plan Review Details - Permit 19101506
Plan Review Stops For Permit 19101506
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-03-30 Cont ID  
Sent By jgomez Date 2020-03-30 Time 15:19 Rev Time 0.00
Received By jgomez Date 2020-03-30 Time 13:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-02-25 Cont ID  
Sent By jgomez Date 2020-02-25 Time 11:13 Rev Time 0.00
Received By jgomez Date 2020-02-24 Time 18:21 Sent To  
Notes
2020-02-24 18:27:23RESIDENTIAL (R3) ALTERATION/ADDITION THIRD BUILDING
 REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #19101506.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 ORIGINAL COMMENT:
 1- THERE IS A NEW OPENING PROPOSED ON THE EAST WALL FOR
 THE INSTALLATION OF THE A/C WALL UNIT. OPENINGS ARE NOT
 ALLOWED ON THE WALL WHEN THE WALL IS LOCATED LESS THAN
 3 FEET FROM THE PROPERTY LINE. REVISE LOCATION OF THE
 A/C WALL UNIT. TABLE R302.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REVISED PLANS NOW SHOW TWO NEW OPENINGS ON THE NORTH
 WALL. ONE WINDOW OPENING AND ONE OPENING FOR THE
 PROPOSED A/C UNIT. SAME COMMENT APPLIES TO THIS NEW
 OPENINGS. OPENINGS ARE NOT ALLOWED ON THIS WALL EITHER
 BECAUSE IT IS LESS THAN 3 FEET FROM THE PROPERTY LINE.
 TABLE R302.1 FBC-RESIDENTIAL. SEE SURVEY AND REVISE AS
 REQUIRED.
  
 2- OK
  
 3- OK.
  
 ORIGINAL COMMENT:
 4- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE
 SPACE. PLANS WERE REVISED SHOWING A NEW DEN ROOM.
  
 A)OK.
  
 B) OK.
  
 ORIGINAL COMMENT:
 C) CLEARLY DENOMINATE THE OTHER ROOM. WHAT IS THE
 PROPOSED USE OF THIS ROOM. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NAME OF THE ROOM IS NOT SPECIFIED ON
 PLANS.
  
 D) OK.
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
  
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
 ****REVIEW IN PROGRESS.........

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-12-31 Cont ID  
Sent By jgomez Date 2019-12-31 Time 14:49 Rev Time 0.00
Received By jgomez Date 2019-12-31 Time 13:40 Sent To  
Notes
2019-12-31 13:45:57RESIDENTIAL (R3) ALTERATION/ADDITION SECOND BUILDING
 REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #19101506.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 ORIGINAL COMMENT:
 1- THERE IS A NEW OPENING PROPOSED ON THE EAST WALL FOR
 THE INSTALLATION OF THE A/C WALL UNIT. OPENINGS ARE NOT
 ALLOWED ON THE WALL WHEN THE WALL IS LOCATED LESS THAN
 3 FEET FROM THE PROPERTY LINE. REVISE LOCATION OF THE
 A/C WALL UNIT. TABLE R302.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOW REVISED PLANS SHOW A NEW ROOM AND
 AN ADDITIONAL OPENING WAS PROPOSED FOR THE INSTALLATION
 OF ANOTHER A/C WALL UNIT ON THE NEW ROOM. NOW THERE ARE
 TWO OPENINGS ON THE EAST WALL. OPENINGS ARE NOT ALLOWED
 ON THE EAST WALL. TABLE R302.1 FBC-RESIDENTIAL. REVISE
 AS REQUIRED.
  
 ORIGINAL COMMENT:
 2- PROPOSED A/C WALL UNIT DOESN'T HAVE HEATING. NEED TO
 PROVIDE UNIT WITH HEATING AS REQUIRED BY SEC. R303.10
 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. AND, NOW 2 UNITS SHOWN
 ON PLANS NEED TO HAVE HEATING.
  
  
 ORIGINAL COMMENT:
 3- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE
 SPACE. TYPICALLY, GARAGES ARE BUILT WITHOUT A FLOOR
 VAPOR BARRIER. ENGINEER OF RECORD TO PROVIDE
 SPECIFICATIONS FOR THE CONCRETE SLAB VAPOR BARRIER AS
 REQUIRED BY SEC. R506.2.3 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 NEW COMMENT:
 4- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE
 SPACE. PLANS WERE REVISED SHOWING A NEW DEN ROOM.
 A) NEED TO SHOW COMPLIANCE WITH THE LIGHT AND
 VENTILATION REQUIREMENTS OF SEC. R303.1
 FBC-RESIDENTIAL.
  
 B) NEED TO SHOW COMPLIANCE WITH THE HEATING
 REQUIREMENTS OF SEC. R303.10 FBC-RESIDENTIAL.
  
 C) CLEARLY DENOMINATE THE OTHER ROOM. WHAT IS THE
 PROPOSED USE OF THIS ROOM. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 D) NEW DEN CAN NOT BE USED FOR SLEEPING PURPOSES
 BECAUSE IT DOESN'T HAVE EGRESS OPENINGS AS REQUIRED BY
 SEC. R310.1 FBC-RESIDENTIAL. CLEARLY STATE ON PLANS
 THAT THIS ROOM CAN NOT BE USED FOR SLEEPING PURPOSES.
 SEC. 107.2.1 CITY AMENDMENTS.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-11-25 Cont ID  
Sent By jgomez Date 2019-11-25 Time 09:52 Rev Time 0.00
Received By jgomez Date 2019-11-25 Time 08:36 Sent To  
Notes
2019-11-25 09:53:05RESIDENTIAL (R3) ALTERATION/ADDITION BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #19101506.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1- THERE IS A NEW OPENING PROPOSED ON THE EAST WALL FOR
 THE INSTALLATION OF THE A/C WALL UNIT. OPENINGS ARE NOT
 ALLOWED ON THE WALL WHEN THE WALL IS LOCATED LESS THAN
 3 FEET FROM THE PROPERTY LINE. REVISE LOCATION OF THE
 A/C WALL UNIT. TABLE R302.1 FBC-RESIDENTIAL.
  
 2- PROPOSED A/C WALL UNIT DOESN'T HAVE HEATING. NEED TO
 PROVIDE UNIT WITH HEATING AS REQUIRED BY SEC. R303.10
 FBC-RESIDENTIAL.
  
 3- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE
 SPACE. TYPICALLY, GARAGES ARE BUILT WITHOUT A FLOOR
 VAPOR BARRIER. ENGINEER OF RECORD TO PROVIDE
 SPECIFICATIONS FOR THE CONCRETE SLAB VAPOR BARRIER AS
 REQUIRED BY SEC. R506.2.3 FBC-RESIDENTIAL.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2020-03-30 Cont ID  
Sent By rmcdouga Date 2020-03-30 Time 18:38 Rev Time 0.00
Received By rmcdouga Date 2020-03-30 Time 18:05 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-02-24 Cont ID  
Sent By jpearson Date 2020-02-24 Time 10:58 Rev Time 0.00
Received By jpearson Date 2020-02-24 Time 10:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-01-02 Cont ID  
Sent By jpearson Date 2020-01-02 Time 11:54 Rev Time 0.00
Received By jpearson Date 2020-01-02 Time 09:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-11-20 Cont ID  
Sent By jpearson Date 2019-11-20 Time 15:14 Rev Time 0.00
Received By jpearson Date 2019-11-20 Time 13:31 Sent To  
Notes
2019-11-20 14:37:14CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. LOAD CALCULAITON SHOWS A DEMAND LOAD OF 128 AMPS.
 THE RISER DIAGRAM STATES THAT THIS IS A 100 AMP PANEL,
 WHICH WOULD BE UNDER SIZED. PROVIDE CORRECTION. NEC
 110.3, 408.30
 2. LOAD CALCULATION INCLUDES AN AHU AT 10,000 WATTS,
 BUT THIS IS NOT SHOWN IN PANEL SCHEDULE. PROVIDE
 ACCURATE LOAD CALCULATION INCLUDING ALL LOADS FOR THIS
 SUB-PANEL. NEC 220; FBC RE E3602.2
 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE
 E3602.2
 4. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A
 DISCONNECTING MEANS AT THE BUILDING OR SEPARATE
 STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR
 MAIN BREAKER AT THE SUB-PANEL. NEC 225.31, 225.32
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2020-03-27 Cont ID  
Sent By fmittner Date 2020-03-27 Time 15:32 Rev Time 0.00
Received By fmittner Date 2020-03-27 Time 15:32 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2020-02-28 Cont ID  
Sent By fmittner Date 2020-02-28 Time 09:53 Rev Time 0.00
Received By fmittner Date 2020-02-28 Time 09:53 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-01-06 Cont ID  
Sent By fmittner Date 2020-01-06 Time 16:13 Rev Time 0.00
Received By fmittner Date 2020-01-06 Time 16:12 Sent To  
Notes
2019-12-31 13:49:16REVISED DRAWINGS SUBMITTED. JG.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-11-04 Cont ID  
Sent By fmittner Date 2019-11-04 Time 11:53 Rev Time 0.00
Received By fmittner Date 2019-11-04 Time 11:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-04-07 Cont ID  
Sent By jgomez Date 2020-04-07 Time 13:42 Rev Time 0.00
Received By jgomez Date 2020-04-07 Time 13:40 Sent To I
Notes
2020-04-07 13:41:05JULIO,
 THE ABOVE REFERENCED PERMIT NUMBER WAS DENIED FOR
 IMPACT FEES
 I HAVE ATTACHED THE APPROVED IMPACT FEES FROM THE
 COUNTY.
 THANK YOU
  
 --
 MARK JENKINS
 ABACOA CONSTRUCTION LLC
 605 BELVEDERE RD
 WEST PALM BEACH FL 33405
 CGC 1513481
 (561)722-3890
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-03-30 Cont ID  
Sent By rmcdouga Date 2020-03-30 Time 18:39 Rev Time 0.00
Received By rmcdouga Date 2020-03-23 Time 08:18 Sent To  
Notes
2020-03-24 08:18:39R18

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-02-28 Cont ID  
Sent By lmarchan Date 2020-02-28 Time 13:55 Rev Time 0.00
Received By lmarchan Date 2020-02-11 Time 14:12 Sent To  
Notes
2020-02-12 14:13:04R12

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-01-07 Cont ID  
Sent By cpuell Date 2020-01-07 Time 14:12 Rev Time 0.00
Received By cpuell Date 2019-12-20 Time 14:09 Sent To  
Notes
2019-12-20 14:09:33R33

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-25 Cont ID  
Sent By jgomez Date 2019-11-25 Time 10:06 Rev Time 0.00
Received By jgomez Date 2019-10-29 Time 15:41 Sent To I
Notes
2019-10-30 15:41:53R12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 5 Status P Date 2020-04-07 Cont ID  
Sent By jgomez Date 2020-04-07 Time 13:42 Rev Time 0.00
Received By jgomez Date 2020-04-07 Time 13:35 Sent To  
Notes
2020-04-07 13:41:59NO FEES DUE. MU-2020-005529.
  
  
 JULIO,
 THE ABOVE REFERENCED PERMIT NUMBER WAS DENIED FOR
 IMPACT FEES
 I HAVE ATTACHED THE APPROVED IMPACT FEES FROM THE
 COUNTY.
 THANK YOU
  
 --
 MARK JENKINS
 ABACOA CONSTRUCTION LLC
 605 BELVEDERE RD
 WEST PALM BEACH FL 33405
 CGC 1513481
 (561)722-3890
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status F Date 2020-03-30 Cont ID  
Sent By jgomez Date 2020-03-30 Time 15:19 Rev Time 0.00
Received By jgomez Date 2020-03-30 Time 15:19 Sent To  
Notes
2020-03-30 15:19:42IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2020-02-25 Cont ID  
Sent By jgomez Date 2020-02-25 Time 11:22 Rev Time 0.00
Received By jgomez Date 2020-02-25 Time 11:22 Sent To  
Notes
2020-02-25 11:22:42IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-12-31 Cont ID  
Sent By jgomez Date 2019-12-31 Time 13:50 Rev Time 0.00
Received By jgomez Date 2019-12-31 Time 13:50 Sent To  
Notes
2019-12-31 13:51:05IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-11-25 Cont ID  
Sent By jgomez Date 2019-11-25 Time 09:57 Rev Time 0.00
Received By jgomez Date 2019-11-25 Time 09:56 Sent To I
Notes
2019-11-25 10:06:57IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2020-03-25 Cont ID  
Sent By medwards Date 2020-03-25 Time 12:54 Rev Time 0.00
Received By medwards Date 2020-03-25 Time 12:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2020-02-25 Cont ID  
Sent By jgomez Date 2020-02-25 Time 11:27 Rev Time 0.00
Received By jgomez Date 2020-02-25 Time 11:22 Sent To  
Notes
2020-02-25 11:27:25RESIDENTIAL (R3) ALTERATION/ADDITION THIRD MECHANICAL
 REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #19101506.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1- OK.
  
 ORIGINAL COMMENT:
 2- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE
 SPACE. IN ADDITION, PLANS WERE REVISED SHOWING A NEW
 DEN ROOM. NEED TO REVISE THE EQUIPMENT SIZING
 CALCULATIONS REFLECTING THE PROPOSED ROOMS. SEC.
 R403.7.1 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-12-31 Cont ID  
Sent By jgomez Date 2019-12-31 Time 14:50 Rev Time 0.00
Received By jgomez Date 2019-12-31 Time 14:50 Sent To  
Notes
2019-12-31 14:51:57RESIDENTIAL (R3) ALTERATION/ADDITION SECOND MECHANICAL
 REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #19101506.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 ORIGINAL COMMENT:
 1- PROPOSED A/C WALL UNIT DOESN'T HAVE HEATING. NEED TO
 PROVIDE UNIT WITH HEATING AS REQUIRED BY SEC. R303.10
 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. AND, NOW 2 UNITS SHOWN
 ON PLANS NEED TO HAVE HEATING.
  
 NEW COMMENT:
 2- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE
 SPACE. IN ADDITION, PLANS WERE REVISED SHOWING A NEW
 DEN ROOM. NEED TO REVISE THE EQUIPMENT SIZING
 CALCULATIONS REFLECTING THE PROPOSED ROOMS. SEC.
 R403.7.1 FBC-ENERGY CONSERVATION.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-11-25 Cont ID  
Sent By jgomez Date 2019-11-25 Time 09:54 Rev Time 0.00
Received By jgomez Date 2019-11-25 Time 09:54 Sent To  
Notes
2019-11-25 09:55:52RESIDENTIAL (R3) ALTERATION/ADDITION MECHANICAL REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #19101506.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1- PROPOSED A/C WALL UNIT DOESN'T HAVE HEATING. NEED TO
 PROVIDE UNIT WITH HEATING AS REQUIRED BY SEC. R303.10
 FBC-RESIDENTIAL.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2020-02-25 Time   Rev Time 0.00
Received By jesmith Date 2020-02-25 Time 12:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-01-02 Cont ID  
Sent By jesmith Date 2020-01-02 Time 09:08 Rev Time 0.00
Received By jesmith Date 2020-01-02 Time 09:07 Sent To  
Notes
2020-01-02 09:08:27PLUMBING COMMENTS: APPROVED W/PROVISO
 1. WATER HEATER SHALL BE PROVIDED WITH ACCESS FOR
 INSPECTION, SERVICE, REPAIR AND REPLACEMENT WITHOUT
 REMOVAL OF PERMANENT CONSTRUCTION TO COMPLY WITH FBC PL
 502.5 PER FBC RES P2601.1
 2. PROVIDE A THERMAL EXPANSION CONTROL DEVICE IN COLD
 WATER SUPPLY TO THE WATER HEATER TO COMPLY WITH FBC RES
 P2903.4
 3. NEW VENTS TRHROUGH ROOF SHALL NOT PENETRATE OR
 PHYSICALLY INTRUDE UPON EXISTING CONCRETE TIE BEAM OR
 BEAM BLOCK.
 4. ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-11-14 Cont ID  
Sent By jesmith Date 2019-11-14 Time 14:41 Rev Time 0.00
Received By jesmith Date 2019-11-14 Time 13:38 Sent To  
Notes
2019-11-14 14:41:41CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
 1. PER WPB FBC 107.2.1, SHOW THAT THE ECOSMART 8 KW
 ELECTRIC TANKLESS WATER HEATER INDICATED ON PLAN SHEET
 E-1 IS CAPABLE OF PROVIDING ADEQUATE HOT WATER AS
 REQUIRED BY FBC RES P2108.1. PROVIDE MANUFACTURER?S
 SPECIFICATION FOR SELECTED WATER HEATER AND INDICATE
 THE DEVICE ON PLAN SHEET P-1.
 2. PLAN SHEET P-1 PROVIDES A SANITARY RISER DIAGRAM AND
 A SANITARY PLAN VIEW LAYOUT. PIPING ON THE TWO DIAGRAMS
 DO NOT MATCH. PER WPB FBC 107.2.1, PLEASE CLARIFY. SEE
 DETAILS BELOW.
 A. THE BUILDING DRAIN EXITS THE BUILDING ON DIFFERENT
 WALLS
 B. THE RISER DIAGRAM IS CODE COMPLIANT.; THE PLAN VIEW
 IS NOT. THE WASHER AND SINK SHALL CONNECT DOWNSTREAM OF
 THE TUB TO COMPLY WITH FBC RES P3108. 1 WET VENTING.
 THE WET VENT CONFIGURATIONS ON THE TWO DIAGRAMS ARE NOT
 IN AGREEMENT.
 3. RE: SANITARY RISER DIAGRAM: PER FBC RES P2604.4,
 SINK AND WASHER UNDER SLAB PIPING SHALL NOT RUN
 PARALLEL WITH BUILDING EDGE IN FOOTER.
 4. WASHER VENT THROUGH THE ROOF SHALL NOT PENETRATE OR
 PHYSICALLY INTRUDE ON THE EXISTING CONCRETE TIE BEAM OR
 BOND BEAM.
 5. HORIZONTAL WASHER DRAIN FROM TRAP TO VENT SHALL
 CONNECT TO VERTICAL ABOVE THE FLOOR TO COMPLY WITH FBC
 RES P2601.1 AND FBC PL 802.3.3 MAXIMUM STANDPIPE
 LENGTH.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19101506 513 45TH ST
  
  
  
  
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2020-03-27 Cont ID  
Sent By fmittner Date 2020-03-27 Time 15:32 Rev Time 0.00
Received By fmittner Date 2020-03-27 Time 15:32 Sent To  
Notes
2020-03-27 15:32:32NOT A SEPARATE UNIT. ONLY ONE UNIT PERMITTED ON SITE.

Review Stop Z ZONING
Rev No 3 Status P Date 2020-02-28 Cont ID  
Sent By fmittner Date 2020-02-28 Time 09:53 Rev Time 0.00
Received By fmittner Date 2020-02-28 Time 09:53 Sent To  
Notes
2020-02-28 09:53:50NOT PERMITTED AS STAND ALONE UNIT

Review Stop Z ZONING
Rev No 2 Status P Date 2020-01-06 Cont ID  
Sent By fmittner Date 2020-01-06 Time 16:11 Rev Time 0.00
Received By fmittner Date 2020-01-06 Time 16:11 Sent To  
Notes
2019-12-31 13:49:07REVISED DRAWINGS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2019-11-04 Cont ID  
Sent By fmittner Date 2019-11-04 Time 11:53 Rev Time 0.00
Received By fmittner Date 2019-11-04 Time 11:53 Sent To  
Notes
2019-11-04 11:54:17NOT PERMITTED AS A SEPERATE UNIT. NO COOKING FACILITIES
 ALLOWED.