Plan Review Details - Permit 19100988
Plan Review Stops For Permit 19100988
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-12-12 Cont ID  
Sent By cthroop Date 2019-12-12 Time 11:29 Rev Time 0.00
Received By cthroop Date 2019-12-12 Time 11:12 Sent To  
Notes
2019-12-12 11:12:48PLAN PAGE REPLACED. BUILDING AND ZONING STAMPS REMOVED.
 CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-11-14 Cont ID  
Sent By cthroop Date 2019-11-14 Time 12:05 Rev Time 0.00
Received By cthroop Date 2019-11-06 Time 16:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-18 Cont ID  
Sent By jpearson Date 2019-12-18 Time 11:17 Rev Time 0.00
Received By jpearson Date 2019-12-18 Time 06:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-11-05 Cont ID  
Sent By jpearson Date 2019-11-05 Time 14:54 Rev Time 0.00
Received By jpearson Date 2019-11-05 Time 11:15 Sent To  
Notes
2019-11-05 14:54:48CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3
 2. NO ELECTRICAL PLAN IS PROVIDED FOR SECOND FLOOR. AT
 A MINIMUM, PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 SMOKE ALARMS, OR PROVIDE A NOTE REQUIRING COMPLIANCE.
 IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS NEW
 INSTALLATIONS. IF THERE IS ANY ADDITIONAL ELECTRICAL
 WORK TO BE COMPLETED ON THE SECOND FLOOR, PROVIDE
 ELECTRICAL PLAN FOR REVIEW. FBC RE R314.3, R315.1; WPB
 FBC 107.2.1
 3. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
 4. FEED TO INTERIOR PANEL IS REQUIRED TO HAVE AN
 EQUIPMENT GROUNDING CONDUCTOR, SIZED PER CODE. PROVIDE
 CORRECTION. NEC 250.122; FBC RE E3704.6, 3607.3.1
 5. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3
 6. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 7. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE
 INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG
 THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET
 FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS
 FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS
 SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE
 IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A
 RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES
 NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION.
 NEC 210.52(C)(1); FBC RE E3901
 8. PLAN SHOWS THE BATHROOM ON A 15 AMP CIRCUIT WITH 14
 GAUGE WIRE. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT
 SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE
 OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS.
 PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4
 9. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE. SEE
 FBC RESIDENTIAL SECTION 3602 FOR FORMULA AND FORMAT
 REQUIRED. NEC 215.2, 220, 408.30; FBC RE E3602.2
 10. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A
 GROUNDING ELECTRODE. THIS GROUNDING ELECTRODE NEEDS TO
 BE AUGMENTED BY AN ADDITIONAL ELECTRODE AT LEAST 6 FEET
 AWAY OR PROVIDE EVIDENCE OF RESISTANCE TO GROUND OF 25
 OHMS OR LESS. PROVIDE CORRECTION. NEC 250.53(A)(2); FBC
 RE E3608.4
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-12-12 Cont ID  
Sent By jesmith Date 2019-12-12 Time 10:44 Rev Time 0.00
Received By jesmith Date 2019-12-10 Time 15:30 Sent To  
Notes
2019-12-12 10:44:36GAS PROVISO
 1. A SEPARATE GAS PERMIT IS REQUIRED. PER WPB FBC
 107.2.1, CONTRACTOR SHALL SUBMIT WITH THE PERMIT
 APPLICATION THE MANUFACTURER?S DATA
 SHEETS/SPECIFICATION/INSTALLATION GUIDE FOR THE GAS
 REGULATOR. REGULATOR SHALL BE APPROVED FOR OUTDOOR USE.
 THE DOCUMENTS SHALL BE SUBMITTED, APPROVED AND ON SITE
 PRIOR TO PERMIT ISSUE.
 2. REFER TO PLAN SHEETS A1.0, A2.1 AND A2.2 FOR
 EXISTING AND RELOCATION INFORMATION CONCERNING THE GAS
 METER.
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-10-24 Cont ID  
Sent By gjohnson Date 2019-10-24 Time 12:04 Rev Time 0.00
Received By gjohnson Date 2019-10-24 Time 12:04 Sent To  
Notes
2019-10-24 12:05:131ST REVIEW: 19100988
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 GAS COMMENTS:
  
 1. SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2017 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & 2017 FUEL GAS CODE
 SEC. 402.4.1.
  
 2. PROVIDE SIZING TABLE FROM FBC FG 402.4 TABLE
 402.4(1-37)
  
 3. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT AND REGULATORS TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND FBC-2017 FUEL GAS SEC.
 402.2
  
 4. PROVIDE SITE PLAN SHOWING ALL GAS PIPING AND GAS
 METER TO CLARIFY NOTE ON GAS RISER PIPING FROM MAIN
 HOUSE TO METER.
  
 5.SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-11-04 Cont ID  
Sent By fmittner Date 2019-11-04 Time 10:38 Rev Time 0.00
Received By fmittner Date 2019-11-04 Time 10:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-01-05 Cont ID  
Sent By cpuell Date 2020-01-05 Time 08:32 Rev Time 0.00
Received By cpuell Date 2019-12-03 Time 15:27 Sent To  
Notes
2019-12-04 15:27:43R12

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-14 Cont ID  
Sent By cthroop Date 2019-11-14 Time 12:10 Rev Time 0.00
Received By cthroop Date 2019-10-18 Time 13:44 Sent To  
Notes
2019-10-21 13:44:55R03

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2019-12-12 Cont ID  
Sent By cthroop Date 2019-12-12 Time 11:25 Rev Time 0.00
Received By cthroop Date 2019-12-12 Time 11:25 Sent To  
Notes
2019-12-12 11:26:17MECHANICAL BY SEPERATE PERMIT PER APPLICANT. CT

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-11-14 Cont ID  
Sent By cthroop Date 2019-11-14 Time 12:05 Rev Time 0.00
Received By cthroop Date 2019-11-12 Time 14:16 Sent To  
Notes
2019-11-14 12:10:31PLAN REVIEW - MECHANICAL
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE ENERGY SUBMITTAL.
  
 FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3
 STORIES.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 2. PROVIDE MECHANICAL PLAN.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-12-12 Cont ID  
Sent By jesmith Date 2019-12-12 Time 10:58 Rev Time 0.00
Received By jesmith Date 2019-12-10 Time 15:54 Sent To  
Notes
2019-12-12 10:57:42PLUMBING COMMENTS: APPROVED W/PROVISO
 1. ROUGH-IN ONLY.
 2. EXTENT OF THE PLUMBING SANITARY ROUGH-IN SHALL BE:
 A. SANITARY UNDERGROUND
 B. IN-WALL SANITARY INCLUSIVE OF HORIZONTAL FIXTURE
 DRAINS, IN-WALL TRAPS, INWALL RECEPTACLES AND VENTS
 THROUGH THE ROOF
 3. IN-WALL WATER DISTRIBUTION INCLUSIVE OF REQUIRED
 IN-WALL WATER HAMMER ARRESTORS AND CONNECTIONS TO GAS
 TANKLESS WATER HEATER. WATER TO BE CAPPED AT FUTURE
 FIXTURE LOCATIONS.
 4. ANY ADDITIONAL CHANGE OR ADDITION TO THE NOTED SCOPE
 ABOVE INCLUDING BUT NOT LIMITED TO FINISHES, IN-WALL
 SHOWER CONTROL VALVES, SHOWER PAN SHALL REQUIRE A NEW
 PERMIT OR A PLAN REVISION NOTING THE CHANGES IN
 SCOPE.(PROVIDED PERMIT IS STILL OPEN)
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-10-24 Cont ID  
Sent By gjohnson Date 2019-10-24 Time 10:31 Rev Time 0.00
Received By gjohnson Date 2019-10-23 Time 16:22 Sent To  
Notes
2019-10-24 11:03:301ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. SHOW THE LAVATORY AND KITCHENETTE SINK ON FLOOR
 PLAN. PER WPB AMEND TO FBC 107.2.1
  
 2. SHOW THE DIMENSIONS OF THE BATHROOM TO DETERMINE
 CODE COMPLIANCE OF FBC RES P2705.1(5)
  
 3. THE SANITARY ISOMETRIC HAS A CODE VIOLATION NOT MORE
 THAN ONE WET-VENTED FIXTURE DRAIN SHALL DISCHARGE
 UPSTREAM OF THE DRY-VENTED FIXTURE DRAIN CONNECTION.THE
 LAVATORY FIXTURE DRAIN SHALL CONNECT BETWEEN THE WATER
 CLOSET AND THE SHOWER. PER FBC RES P3108.2.1
  
 4. PLEASE CLARIFY ON THE PLAN NOTE STATES ROUGH IN
 ONLY, IS IT FOR UNDERGROUND PIPING OR WILL THE WATER
 AND SANITARY BE INSTALLED IN THE WALLS ALSO. PER WPB
 AMEND TO FBC 107.2.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2019-11-14 Cont ID  
Sent By cthroop Date 2019-11-14 Time 12:11 Rev Time 0.00
Received By cthroop Date 2019-11-14 Time 12:11 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-01-03 Cont ID  
Sent By fmittner Date 2020-01-03 Time 15:53 Rev Time 0.00
Received By fmittner Date 2020-01-03 Time 15:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-11-04 Cont ID  
Sent By fmittner Date 2019-11-04 Time 10:38 Rev Time 0.00
Received By fmittner Date 2019-11-04 Time 10:38 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved