Plan Review Details - Permit 19100813
Plan Review Stops For Permit 19100813 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-11-20 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-11-20 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-10-28 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-10-28 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-10-28 |
Time |
08:54 |
Sent To |
|
|
Notes |
2019-10-28 13:32:45 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 19100813 | | REVIEWED: OCTOBER 28, 2019 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC[B] = FBC BUILDING | | | | 1) 107.5.3 FBC[AMENDED]PLEASE SHOW THE GENERATOR WITH | | ENCLOSURE IMPOSED ON A FLOOR PLAN TO SHOW HOW EGRESS | | WILL WORK. THE ENCLOSURE SHOWN ON THE GENERATOR | | SUBMITTAL IN PERMIT 19100815 SHOWS DIMENSIONS OF 10 | | FEET WIDE BY 28 FOOT 4 INCHES LONG. THE SUBMITTAL ALSO | | SHOWS THE ACCESS DOORS ARE 4 FOOT OUTSWING. | | SHEET C-400 APPEARS TO SHOW OUTLNE WITH 3 FEET AROUND | | THE UNIT FOR ACCESS. | | IS THE INTENTION TO HAVE ACCESS DOORS SWING ALL THE WAY | | OPEN? | | PLEASE VERIFY THE SIZE OF ACCESS DOORS AND IF THEY WILL | | BE OBSTRUCTED FROM FULL OPEN BY THE MASONRY WALL. | | | | 2) 107.2.1.1 FBC[AMENDED]PROVIDE PRODUCT APPROVAL FOR | | THE ROLLING DOOR ATTACHED TO WALL THAT IS BEING USED | | FOR ACCESS TO THE GENERATOR. | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | [email protected] | | | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2019-11-20 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2019-11-20 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2019-11-05 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2019-11-05 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2019-11-05 |
Time |
|
Sent To |
|
|
Notes |
2019-11-05 15:15:50 | 1) SHOW PROPOSED DUMPSTER ENCLOSURE TO BE COMPLIANT | | WITH CITY OF WPB STANDARD DETAIL GC-8. | | 2) PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | AREAS. | | 3) PLEASE RESPOND TO ALL COMMENTS IN WRITING. | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | CONCERNS, THANKS. | | | | RICK ROSSANO, PROJECT COORDINATOR | | ENGINEERING SERVICES DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 (MAILING ADDRESS: P.O. BOX | | 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 DIRECT: (561) 494-1098 FAX: | | (561) 494-1116 MOBILE: (561) 246-9525 | | EMAIL: [email protected] WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-11-20 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-11-20 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-11-14 |
Time |
09:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-11-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-11-05 |
Time |
18:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-10-17 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-11-20 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-11-20 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-10-28 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-10-28 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-10-28 |
Time |
09:04 |
Sent To |
|
|
Notes |
2019-10-28 09:05:04 | OK-INITIAL REVIEW SHEETS. | | IF ANY ADDITIONAL SHEETS ARE PROVIDED THEY WILL NEED TO | | BE DIGITALLY SIGNED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-11-20 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2019-11-20 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2019-11-20 |
Time |
10:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-11-05 |
|
|
Cont ID |
|
Sent By |
avann |
Date |
2019-11-05 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2019-11-05 |
Time |
16:16 |
Sent To |
|
|
Notes |
2019-11-05 16:18:59 | 11/5/19- FAILED. 1. IS PARKING BEING REMOVED REQUIRED | | PARKING? 2. A FIVE (5) FOOT LANDSCAPE BUFFER IS | | REQUIRED AROUND THE DUMPSTER AND GENERATOR ENCLOSURES. | | | | ANGELLA VANN, AICP | | 561-822-1441 | | [email protected] |
|
|
|