Plan Review Details - Permit 19100754
Plan Review Stops For Permit 19100754
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2019-11-04 Cont ID  
Sent By jwitmer Date 2019-11-04 Time 10:17 Rev Time 0.00
Received By jwitmer Date 2020-01-13 Time 06:18 Sent To  
Notes
2019-11-04 10:17:31BUILT IN 2004.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-01-13 Cont ID  
Sent By jwitmer Date 2020-01-13 Time 07:40 Rev Time 0.00
Received By jwitmer Date 2020-01-13 Time 07:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-11-04 Cont ID  
Sent By jwitmer Date 2019-11-04 Time 10:17 Rev Time 0.00
Received By jwitmer Date 2019-11-04 Time 05:45 Sent To  
Notes
2019-11-04 10:16:532017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19100754
 ADD: 801 S. OLIVE AVE. SUITE: 1105
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-588-5070
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. NOV. 04TH/ 2019
 ACTION: DENIED
  
 1) SHEET A-1 THE COVERSHEET:
 1A) THE COVERSHEET LIST THE BUILDING TYPE AS
 CONSTRUCTION TYPE II SPRINKLERED. THIS HIGHRISE IS A 15
 STORY BUILDING. THE CONSTRUCTION TYPE UNDER THE 2017
 FBC-B TABLE 504.4 IS CONSTRUCTION TYPE I-A. PLEASE
 CORRECT.
  
 1B) THE COVERSHEET LIST THE OCCUPANCY TYPE AS R-3. A
 R-3 OCCUPANCY IN THE 2017 FBC-B WOULD BE A MIXED USE
 BUILDING, FOR EXAMPLE, MERCANTILE 1ST FLOOR, AND A
 SINGLE RESIDENTIAL UNIT ON THE 2ND FLOOR, THIS WHERE A
 R-3 OCCUPANCY COULD OCCUR UNDER THE COMMERCIAL CODE.
 APARTMENT BUILDINGS WITH NON-TRANSIENT OCCUPANTS AND
 CONDOMINIUM BUILDINGS WITH LONG TERM NON-TRANSIENT
 RESIDENTS ARE CONSIDERED AN R-2 OCCUPANCY. SEE 2017
 FBC-B SECTION 310.4.
  
 1C) IN THE COVERSHEET/ DEMOLITION PLAN INDICATES TO
 DEMOLISH THE ENTIRE MASTER BATH. IF THIS IS SO, THEN
 COMPLIANCE WITH FLOOR INSULATION WILL BE REQUIRED.
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2017)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS (NOT SALES BROCHURES)
 SHOWING COMPLIANCE WITH:
  
 1C)(1) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1C)(2) FBC-B 2017 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 1C)(3) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 2) SHEET A-2:
 2A) SHEET A-2 HAS A DETAIL B TYPICAL SOFFIT WITH A NOTE
 TO USE TAPCONS ? INCH DIAMETER, AND A MAXIMUM EMBEDMENT
 OF ? INCH. IN GOING TO THE TAPCON TECHNICAL
 SPECIFICATIONS FOR TAPCON CONCRETE SCREWS THE MINIMUM
 TAPCON SIZE SHOWN ON THE CHARTS IS 1 ? INCH IN LENGTH.
 THE MINIMUM EMBEDMENT LENGTH IS 1 INCH. WITH THIS
 KNOWLEDGE YOU WILL NEED NOTE SO ON THE PLANS TO HAVE
 THE SLAB X-RAYED BEFORE DRILLING FOR TAPCONS TO LOCATE
 THE EXISTING POST-TENSION TENDONS EMBEDDED WITHIN THE
 SLAB. PLEASE ALSO UPDATE THE PLANS AS TO THE MINIMUM
 LENGTH OF THE TAPCON. SHOW COMPLIANCE WITH FBC-B
 1703.6.2.
  
 2B) THE FLOOR PLAN OF THE MASTER BATHROOM AND SHOWER
 SHOWS A NICHE IN THE 1 HOUR RATED CORRIDOR WALL COMMON
 TO THE SHOWER. THERE IS ALSO A NOTE THAT 5/8 INCH TYPE
 X DRYWALL ARE TO BE ATTACHED TO ALL SIDES OF THE NICHE.
 PLEASE NOTE THERE IS ANOTHER CONCERN NOT ONLY THE FIRE
 RATING BUT ALSO THE REQUIREMENTS FOUND IN SECTION
 2509.2 BASE FOR TILE.
  
 2017 FBC-B2509.2 BASE FOR TILE. MATERIALS USED AS A
 BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND
 CEILING PANELS IN SHOWER AREAS SHALL BE OF MATERIALS
 LISTED IN TABLE 2509.2 AND INSTALLED IN ACCORDANCE WITH
 THE MANUFACTURER?S RECOMMENDATIONS. WATER-RESISTANT
 GYPSUM BACKING BOARD SHALL BE USED AS A BASE FOR TILE
 IN WATER CLOSET COMPARTMENT WALLS WHEN INSTALLED IN
 ACCORDANCE WITH GA-216 OR ASTM C840 AND THE
 MANUFACTURER?S RECOMMENDATIONS. REGULAR GYPSUM
 WALLBOARD IS PERMITTED UNDER TILE OR WALL PANELS IN
 OTHER WALL AND CEILING AREAS WHEN INSTALLED IN
 ACCORDANCE WITH GA-216 OR ASTM C840.
  
 TABLE 2509.2
 BACKERBOARD MATERIALS
  
 MATERIAL_______________________________________
 STANDARD
 GLASS MAT GYPSUM BACKING PANEL ____________________ASTM
 C1178
 NONASBESTOS FIBER-CEMENT BACKER BOARD__________ ASTM
 C1288 OR ISO 8336,
 _______________________________________________CATEGORY
 C
  
 NONASBESTOS FIBER-MAT REINFORCED ___________________
 ASTM C1325
 CEMENTITIOUS BACKER UNIT
  
 2509.3 LIMITATIONS. WATER-RESISTANT GYPSUM BACKING
 BOARD SHALL NOT BE USED IN THE FOLLOWING LOCATIONS:
 1.OVER A VAPOR RETARDER IN SHOWER OR BATHTUB
 COMPARTMENTS.
 2.WHERE THERE WILL BE DIRECT EXPOSURE TO WATER OR IN
 AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY.
  
 2C) WITHIN THE MASTER BATHROOM THE PLANS ALSO INDICATE
 THE USE OF TRANSLUCENT BYPASS DOOR ENCLOSURE TO THE
 WATER CLOSET ROOM. THE USE OF GLASS PRODUCTS IN THIS
 APPLICATION IS CONSIDERED A HAZARDOUS LOCATION SEE THE
 2017 FBC-B SECTION 2406.4.1.
 2406.2 IMPACT TEST. WHERE REQUIRED BY OTHER SECTIONS OF
 THIS CODE, GLAZING SHALL BE TESTED IN ACCORDANCE WITH
 CPSC 16 CFR PART 1201. GLAZING SHALL COMPLY WITH THE
 TEST CRITERIA FOR CATEGORY II, UNLESS OTHERWISE
 INDICATED IN TABLE 2406.2(1).
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-01-09 Cont ID  
Sent By jpearson Date 2020-01-09 Time 12:57 Rev Time 0.00
Received By jpearson Date 2020-01-09 Time 07:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-11-06 Cont ID  
Sent By jpearson Date 2019-11-06 Time 12:49 Rev Time 0.00
Received By jpearson Date 2019-11-05 Time 11:14 Sent To I
Notes
2019-11-06 12:49:53CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE
 OUTLETS IN BATHROOM. PROVIDE CORRECTION. NEC 210.8
 2. PROVIDE TAMPER RESISTANT RECEPTACLES PER NEC 406.12.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-01-03 Cont ID  
Sent By pleduc Date 2020-01-03 Time   Rev Time 0.00
Received By pleduc Date 2020-01-03 Time 11:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-10-21 Cont ID  
Sent By pleduc Date 2019-10-21 Time   Rev Time 0.00
Received By pleduc Date 2019-10-21 Time 12:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-01-13 Time   Rev Time 0.00
Received By lmarchan Date 2019-12-27 Time 13:54 Sent To  
Notes
2019-12-27 13:54:08B03

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-11-06 Time   Rev Time 0.00
Received By lmarchan Date 2019-10-16 Time 13:05 Sent To  
Notes
2019-10-17 13:05:54B01

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-01-06 Cont ID  
Sent By ccole Date 2020-01-06 Time 10:19 Rev Time 0.00
Received By ccole Date 2020-01-06 Time 10:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-10-31 Cont ID  
Sent By ccole Date 2019-10-31 Time 16:28 Rev Time 0.00
Received By ccole Date 2019-10-31 Time 15:26 Sent To  
Notes
2019-10-31 16:31:031ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19100754
 10/31/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-3: IT APPEARS THE NEW EXHAUST FAN WILL BE
 LOCATED IN AN ENCLOSED TOILET COMPARTMENT. HOW WILL
 EXHAUST VENTILATION BE PROVIDED FOR THE REST OF THE
 BATHROOM - TABLE 403.3.1.1 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-01-23 Cont ID  
Sent By jesmith Date 2020-01-23 Time 12:21 Rev Time 0.00
Received By jesmith Date 2020-01-23 Time 11:55 Sent To  
Notes
2020-01-23 12:20:52PLUMBING COMMENTS: APPROVED
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-01-02 Cont ID  
Sent By jesmith Date 2020-01-02 Time 14:48 Rev Time 0.00
Received By jesmith Date 2020-01-02 Time 14:47 Sent To  
Notes
2020-01-02 14:48:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 2ND REVIEW
  
  
 PLUMBING COMMENTS: DENIED
  
 1. PER WPB FBC 107.2.1, PROVIDE CLEAR FLOOR SPACES FOR
 APPLICABLE BATHROOMS TO SHOW COMPLIANCE WITH THE FAIR
 HOUSING ACT. COMPLIED
  
 2. THE SANITARY ISOMETRIC FOR THE WASHER/SHOWER/WATER
 CLOSET STACKS IS NON-COMPLIANT. PER WPB FBC 107.2.1,
 SHOW HOW THE FIXTURES ARE BEING VENTED IN ACCORDANCE
 WITH THE REQUIREMENTS OF FBC PL CHAPTER 9.
 DID NOT COMPLY: A SANITARY ISOMETRIC IS STILL REQUIRED
 TO SHOW CAPPED TUB DRAIN, CONNECTIONS OF THE TWO
 RECONFIGURED LAVATORIES AND CAPPING OF RELOCATED
 LAVATORY WHICH WAS ADJACENT TO THE SHOWER. SHOW VENTING
 AND DRAINAGE OF ALL FIXTURES AND CONNECTIONS TO STACKS.
  
 3. ANY NEW FLOOR PENETRATIONS SHALL MEET THE
 REQUIREMENTS OF FBC CHAPTER 7.
 DID NOT COMPLY
 THE WATER CLOSET FLOOR PENETRATION WILL HAVE TO BE
 RELOCATED IN ORDER TO PHYSICALLY ACCOMMODATE THE
 RECONFIGURATION OF THE FIXTURE.
 ADDITIONALLY THE DELETED TUB PENETRATION OPENING WILL
 HAVE TO BE SAFED
  
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19100754 801 S OLIVE AVE 1105
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-10-22 Cont ID  
Sent By jesmith Date 2019-10-22 Time 14:31 Rev Time 0.00
Received By jesmith Date 2019-10-22 Time 14:31 Sent To  
Notes
2019-10-22 14:31:41CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
 1. PER WPB FBC 107.2.1, PROVIDE CLEAR FLOOR SPACES FOR
 APPLICABLE BATHROOMS TO SHOW COMPLIANCE WITH THE FAIR
 HOUSING ACT.
 2. THE SANITARY ISOMETRIC FOR THE WASHER/SHOWER/WATER
 CLOSET STACKS IS NON COMPLIANT. PER WPB FBC 107.2.1,
 SHOW HOW THE FIXTURES ARE BEING VENTED IN ACCOERDANCE
 WITH THE REQUIREMENTS OF FBC PL CHAPTER 9.
 3. ANY NEW FLOOR PENETRATIONS SHALL MEET THE
 REQUIREMENTS OF FBC CHAPTER 7.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19100754 801 S OLIVE AVE 1105
  