Plan Review Details - Permit 19100631
Plan Review Stops For Permit 19100631
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2019-11-06 Cont ID  
Sent By dbattles Date 2019-11-06 Time 15:29 Rev Time 0.00
Received By dbattles Date 2019-11-06 Time 15:29 Sent To  
Notes
2019-11-06 15:30:30ADDRESS UPDATED TO 263 BANYAN BLVD

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2019-11-06 Cont ID  
Sent By shill Date 2019-11-06 Time 06:34 Rev Time 0.00
Received By shill Date 2019-11-06 Time 06:13 Sent To  
Notes
2019-11-06 06:14:01PRIOR TO ISSUANCE, THE ADDRESS FOR THIS APPLICATION IS
 TO BE CHANGED TO 263 BANYAN BLVD. NO ACTION ON THE PART
 OF THE CUSTOMER IS REQUIRED; THIS IS BEING HANDLED
 INTERNALLY.
 [email protected], 561-805-6724
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2019-11-06 Cont ID  
Sent By dbattles Date 2019-11-04 Time 09:11 Rev Time 0.00
Received By dbattles Date 2019-11-01 Time 13:53 Sent To  
Notes
2019-11-06 15:25:58NEW CONSTRUCTION-NO ASBESTOS REQUIREMENTS
2019-11-04 09:25:02BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19100631
 REVIEWED: NOVEMBER 4, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
  
 105.9 ASBESTOS. THE ENFORCING AGENCY SHALL REQUIRE EACH
 BUILDING PERMIT FOR THE DEMOLITION OR RENOVATION OF AN
 EXISTING STRUCTURE TO CONTAIN AN ASBESTOS NOTIFICATION
 STATEMENT WHICH INDICATES THE OWNERS OR OPERATORS
 RESPONSIBILITY TO COMPLY WITH THE PROVISIONS OF SECTION
 469.003, FLORIDA STATUTES, AND TO NOTIFY THE DEPARTMENT
 OF ENVIRONMENTAL PROTECTION OF HIS OR HER INTENTIONS TO
 REMOVE ASBESTOS, WHEN APPLICABLE, IN ACCORDANCE WITH
 STATE AND FEDERAL LAW. REFER TO SECTION 105.3.6
 ""ASBESTOS REMOVAL CONTRACTOR EXEMPTION"" FOR
 ADDITIONAL REQUIREMENTS.
 - ANY ADDITIONAL REQUIREMENTS ARE THROUGH, PALM BEACH
 COUNTY HEALTH DEPARTMENT ENVIRONMENTAL HEALTH AND
 ENGINEERING ASBESTOS PROGRAM COORDINATOR (561)837-5900
  -IS THERE A DEMOLITION PLAN FOR THIS PROJECT? PLEASE
 PROVIDE THE DEMOLITION PLAN. ALSO, PROVIDE THE
 NOTIFICATION CORESPONDENCE THAT WAS TO BE PROVIDED TO
 THE PALM BEACH COUNTY HEALTH DEPARTMENT.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-11-21 Cont ID  
Sent By dbattles Date 2019-11-21 Time 15:03 Rev Time 0.00
Received By dbattles Date 2019-11-21 Time 15:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-11-04 Cont ID  
Sent By dbattles Date 2019-11-04 Time 09:11 Rev Time 0.00
Received By dbattles Date 2019-11-01 Time 13:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-11-06 Cont ID  
Sent By jpearson Date 2019-11-06 Time 07:03 Rev Time 0.00
Received By jpearson Date 2019-11-06 Time 07:03 Sent To  
Notes
2019-11-06 07:03:41PASSED WITH PROVISO FOR SEPARATE PERMITS

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-11-01 Cont ID  
Sent By jpearson Date 2019-11-01 Time 12:54 Rev Time 0.00
Received By jpearson Date 2019-11-01 Time 12:54 Sent To  
Notes
2019-11-01 12:54:06CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. FIRE ALARM AND LOW VOLTAGE ARE REQUIRED TO BE A
 SEPARATE PERMIT WITH SEPARATE PLAN SUBMITTAL. . PROVIDE
 A BLOCK NOTE INDICATING THE REQUIRED SEPARATE PERMITS
 AND PLAN SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT.
 WPB FBC 105.1, 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-10-16 Cont ID  
Sent By J.Walker Date 2019-10-16 Time   Rev Time 0.00
Received By jwalker Date 2019-10-16 Time   Sent To B
Notes
2019-10-16 12:08:14PROVISO:
 ANY MODIFICATIONS TO NEW OR EXISTING FIRE ALARM OR FIRE
 SPRINKLER SYSTEMS WILL REQUIRE SEPERATE PLANS AND
 PERMITS.
 NFPA 13
 NFPA 72

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-05 Cont ID  
Sent By shill Date 2019-12-05 Time 12:06 Rev Time 0.00
Received By shill Date 2019-11-19 Time 11:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-14 Cont ID  
Sent By lmarchan Date 2019-11-14 Time 15:30 Rev Time 0.00
Received By lmarchan Date 2019-10-12 Time 08:51 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2019-11-14 Cont ID  
Sent By dbattles Date 2019-11-14 Time 09:46 Rev Time  
Received By lmarchan Date 2019-11-04 Time 09:25 Sent To  
Notes
2019-11-14 09:46:31IMPACT FEES PAID UNDER SHELL PERMIT - SEE RECEIPT
 2018-018063.
2019-11-06 15:26:39IMPACT PAID WITH SHELL PERMIT.
2019-11-04 09:27:04WHAT WAS THE PREVIOUS OCCUPANCY OF THIS SPACE?
 IS THIS A CHANGE OF OCCUPANCY?
  
 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE
 R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU
 ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE
 UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-10-24 Cont ID  
Sent By ccole Date 2019-10-24 Time 11:31 Rev Time 0.00
Received By ccole Date 2019-10-24 Time 09:49 Sent To  
Notes
2019-10-24 11:31:58MECH PROVISOS ON SHEETS M1.00 & M2.01

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-12-05 Cont ID  
Sent By shill Date 2019-12-05 Time 12:05 Rev Time 0.00
Received By shill Date 2019-11-22 Time 17:07 Sent To  
Notes
2019-12-05 12:06:02REVIEWED REMOTELY BY TIM HUNT
 APPROVED WITH RED LINE PROVISO**30MIN**
  
 1) SIDE GRAB BARS SHALL BE MIN 54? OVERALL. FBC-ACC
 604.5.1 ON SHT. A2.1.1
 2) TEMPERING DEVICE SHALL BE AN APPROVED ASSE 1070
 VALVE. FBC-PLB 607.1.2. ON SHT. P2.01
  
2019-12-03 09:11:10TIM HUNT REVIEWING REMOTELY

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-10-25 Cont ID  
Sent By gjohnson Date 2019-10-25 Time 09:35 Rev Time 0.00
Received By gjohnson Date 2019-10-24 Time 14:01 Sent To  
Notes
2019-10-31 07:20:371ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915
 MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP
 OF THE GRIPPING SURFACE. PER FBC PL 609.4
  
 2. SHT 2.1.1 DETAIL #B SHOWS CENTER OF TOILET AT 1'-6"
 OFF SIDE WALL DETAIL #7 SHOWS CENTER OF TOILET1'-5" OFF
 SIDE WALL PLEASE CLARIFY. PER FBC ACC 604.2
  
 3. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE REAR WALL
 AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL. PER
 FBC ACC 604.5.1
  
 4. A BACKFLOW IS REQUIRED ON ANY ICE MAKERS AND COFFEE
 MAKERS. PER FBC PL 608.3, 608.16.10
  
 5. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES
 AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET
 FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3. FBC PL 416.5
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-11-21 Cont ID  
Sent By dbattles Date 2019-11-21 Time 15:03 Rev Time 0.00
Received By dbattles Date 2019-11-21 Time 15:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-11-01 Cont ID  
Sent By dbattles Date 2019-11-01 Time 13:58 Rev Time 0.00
Received By dbattles Date 2019-11-01 Time 13:58 Sent To  
Notes
2019-11-01 14:01:30ANY NEW SHEETS PROVIDED NEED TO BE DIGITALLY SIGNED.
2019-11-01 12:47:09ELECTRICAL SHEETS: PER THE WPB AMENDMENTS TO THE FBC,
 EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED
 BY THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL
 PLAN REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD
 PARTY VERIFICATION. SELF-CERTIFICATION IS NOT
 ACCEPTABLE FOR ENGINEERS. ADDITIONALLY, THE DIGITAL
 SIGNATURE MUST INCLUDE THE STATEMENT "SIGNED AND
 SEALED" WHEN A DIGITAL SEAL IS NOT ON THE PLAN, AS PER
 FAC 61G15-23.004. PROVIDE CORRECTION. WPB FBC 107.1; FS
 471/481

Review Stop Z ZONING
Rev No 1 Status P Date 2019-11-14 Cont ID  
Sent By aaponte Date 2019-11-14 Time 15:28 Rev Time 0.00
Received By aaponte Date 2019-11-14 Time 15:28 Sent To  
Notes
***NONE***