Plan Review Details - Permit 19100611
Plan Review Stops For Permit 19100611
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-10-11 Cont ID  
Sent By skennedy Date 2019-10-11 Time 10:19 Rev Time 0.00
Received By skennedy Date 2019-10-11 Time 10:19 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-10-15 Cont ID  
Sent By sathomas Date 2019-10-15 Time 00:00 Rev Time 0.00
Received By sathomas Date 2019-10-15 Time 00:00 Sent To B
Notes
2019-10-15 15:22:34PROVISO:
 1. PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
 PROVIDE TYPE K EXTINGUISHERS WHEN COOKING WITH GREASE
 OR WHEN PRODUCING SMOKE OR GREASE-LADEN VAPORS.
 2. TENTS SHALL BE LOCATED AT LEAST 10 FEET AWAY FROM
 BUILDING STRUCTURES.
 3. TENT SHALL BE OF THE OPEN AREA/NO SIDEWALL TYPE,
 OTHERWISE EMERGENCY LIGHTING AND ILLUMINATED EXIT SIGNS
 ARE REQUIRED FOR TENTS EXCEEDING 1,200 SQUARE FEET.
 4. POST WEATHERPROOF NO SMOKING SIGNS IN CONSPICUOUS
 LOCATIONS.
 5. PROVIDE NONCOMBUSTIBLE FLAME CERTIFICATE FOR THE
 CANOPY MATERIAL.
 6. GENERATORS AND OTHER INTERNAL COMBUSTION POWER
 SOURCES SHALL BE SEPARATED FROM TENTS BY A MINIMUM OF 5
 FEET AND SHALL BE PROTECTED FROM CONTACT BY FENCING OR
 ENCLOSURE.
 7. OPEN-AIR MERCANTILE OPERATIONS: PER NFPA 101 SECTION
 36.4.3.3, MERCANTILE OPERATIONS THAT ARE CONDUCTED IN
 ROOFED-OVER AREAS SHALL BE TREATED AS MERCANTILE
 BUILDINGS, PROVIDED THAT CANOPIES OVER INDIVIDUAL SMALL
 STANDS TO PROTECT MERCHANDISE FROM THE WEATHER ARE NOT
 CONSTRUED AS CONSTITUTING BUILDINGS FOR THE PURPOSE OF
 THIS CODE. THE INTENT OF 36/37.4.3.3 IS TO EXEMPT SMALL
 MERCHANDISE STANDS WITH CANOPIES FROM CLASSIFICATION AS
 MERCANTILE BUILDINGS. ALL OTHER ROOFED-OVER AREAS
 SHOULD BE TREATED AS BUILDINGS CLASSIFIED BY AREA AND
 HEIGHT AS CLASS A, CLASS B, OR CLASS C MERCANTILE
 OCCUPANCIES AND ARE SUBJECT TO THE APPROPRIATE
 PROVISIONS OF CHAPTERS 36 AND 37 OF THE LIFE SAFETY
 CODE.
  
 S. THOMAS
 561-804-4728

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-16 Cont ID  
Sent By sholder Date 2019-10-16 Time 16:48 Rev Time 0.00
Received By sholder Date 2019-10-10 Time 17:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-10-15 Cont ID  
Sent By eschneid Date 2019-10-15 Time 09:51 Rev Time 0.25
Received By eschneid Date 2019-10-15 Time 09:51 Sent To  
Notes
***NONE***