Plan Review Details - Permit 19100555
Plan Review Stops For Permit 19100555 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-11-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-10-30 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-10-30 |
Time |
17:22 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-10-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-10-15 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-10-15 |
Time |
07:59 |
Sent To |
|
|
Notes |
2019-10-15 08:07:41 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT SIGNED AND SEALED GENERATOR PAD AND ANCHORING | | DETAILS. THE ONES THAT WERE SUBMITED ARE COPIES. | | 61G15-23.003 PROCEDURES FOR PHYSICALLY SIGNING AND | | SEALING PLANS, SPECIFICATIONS, REPORTS OR OTHER | | DOCUMENTS. | | ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER | | DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN | | ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025, | | F.S., AND RULE 61G15-23.001, F.A.C. MUST BE PHYSICALLY | | SIGNED, DATED AND SEALED AS PROVIDED HEREIN BY THE | | PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE. | | (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE | | LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE | | SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR | | COPIED IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE | | USED. | | (2) THE LICENSEE MUST THEN USE A WET SEAL, A DIGITALLY | | CREATED SEAL, OR AN EMBOSSING SEAL PLACED PARTIALLY | | OVERLAPPING THE LICENSEE?S SIGNATURE ON EACH PAGE | | REQUIRED TO BE SEALED. THE PLACEMENT OF THE SEAL SHALL | | NOT RENDER THE SIGNATURE ILLEGIBLE. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-10-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-10-16 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-10-16 |
Time |
08:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-10-17 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-10-17 |
Time |
07:58 |
Sent To |
|
|
Notes |
2019-10-17 07:59:25 | 10/17/19 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-10-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-11-04 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-10-29 |
Time |
15:35 |
Sent To |
|
|
Notes |
2019-10-30 15:36:01 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-10-17 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-10-10 |
Time |
14:12 |
Sent To |
|
|
Notes |
2019-10-10 14:12:34 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-10-11 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2019-10-11 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2019-10-11 |
Time |
13:32 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy