Plan Review Stops For Permit 19100548 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2022-08-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-08-01 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-08-01 |
Time |
10:37 |
Sent To |
|
|
Notes |
2022-08-01 10:37:44 | WORK TO BE DONE ON THE NORTH DOWNSTAIRS UNIT WITH THE | | ADDRESS OF 416 42ND ST # A, UPDATED PERMIT. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2021-06-09 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-06-09 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-06-09 |
Time |
16:56 |
Sent To |
|
|
Notes |
2021-06-09 16:57:17 | PREVIOUS COMMENTS NOT ADDRESSED, PLEASE CONTACT | | [email protected] TO DISCUSS ADDRESSING ISSUES. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2021-03-09 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2021-03-09 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2021-03-09 |
Time |
15:07 |
Sent To |
|
|
Notes |
2021-03-09 15:07:53 | PARCEL CURRENTLY HAS 4 UNITS IDENTIFIED, PLEASE SPECIFY | | THE UNITS EFFECTED BY THIS PERMIT. PLEASE EMAIL | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-08-15 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-08-12 |
Time |
18:14 |
Sent To |
|
|
Notes |
2022-08-15 13:51:50 | RESIDENTIAL (R3) ALTERATION SEVENTH BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT #:19100548 416 42ND ST # A | | | | NOTE: | | LEVEL 3 ALTERATION. SEC. 505 FBC-EXISTING BUILDING. | | SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | NOTE: | | ADDITIONS SEC. 507 FBC-EXISTING BUILDING. SEC. 1101.1 | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | R101.5 FBC-ENERGY CONSERVATION. | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID | | CONFLICTS/DELAYS. | | | | A)FORM R405-2020 SUBMITTED IS THE WRONG FORM. THIS | | PROJECT IS REVIEWED UNDER THE 2017 CODE. PROVIDE | | CORRECT FORM R405-2017 AS DONE ON PREVIOUS SUBMITTAL. | | | | B) THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR | | OTHER AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER | | SHALL CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF | | FORM THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, | | AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO | | RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | RENOVATION AS REQUIRED BY SECTION R101.5.1.1.2 | | FBC-RESIDENTIAL. | | | | C)CONDITIONED FLOOR AREA ON PAGE ONE DOESN'T MATCH AREA | | SHOWN ON PLANS. | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | NOTE: IT IS NOT CLEAR IF THE ENERGY CALCULATIONS ARE | | DONE FOR ENTIRE FIRST FLOOR OR JUST THE REBUILT FIRST | | FLOOR BEDROOM. REVISE AS REQUIRED. | | ENERGY CALCULATIONS MAY DONE JUST FOR THE NEW | | CONSTRUCTION OF THE BEDROOM AS SHOWN ON PLANS TO AVOID | | MORE CONFLICTS/DELAYS. | | | | D)REVISE WALL TYPE INFORMATION ON PAGE ONE. COORDINATE | | WITH ITEM #1(B) ABOVE. | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | E) REVISE BLOCKS, SPACES, FLOORS, ROOF AND ATTIC | | INFORMATION ON PAGE 2. COORDINATE WITH ITEM #1(B) | | ABOVE. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | F)REVISE CEILING, WALL, DOORS, WINDOWS AND HEATING | | SYSTEM INFORMATION ON PAGE 3. COORDINATE WITH ITEM | | #1(B) ABOVE. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | G)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE | | LEVEL (EPL) DISPLAY CARD SUBMITTED SEC. R405.4.3 FBC- | | ENERGY CONSERVATION. | | | | 2- OK. | | | | | | NOTE: | | ARCHITECTURAL PLANS SUBMITTED ARE OLD PLANS. THEY WERE | | SIGNED AND SEALED BY THE ARCHITECT OF RECORD ON | | 7/21/20. THE FOLLOWING COMMENTS ARE BASED ON THESE OLD | | PLANS. | | | | | | 3- SHEET 1.1: NEED TO SPECIFY MIN. 5/8" ROOF SHEATHING | | AS REQUIRED BY SEC. TABLE R803.1 FBC-RESIDENTIAL. | | NOTE: THIS COMMENT APPLIES TO TYPICAL WOOD FRAME WALL | | SECTION ON SHEET 3.1 ALSO. | | | | 4- OK | | | | 5- DOOR AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET 2.1 | | ARE TOO LOW IF THEY ARE DONE USING TABLE R301.2(2) | | FBC-RESIDENTIAL AND HEIGHT AND EXPOSURE ADJUSTMENT | | TABLE R301.2(3) FBC-RESIDENTIAL. REVISE AS REQUIRED. | | USE THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA | | AS REQUIRED BY FOOTNOTE "B" OF THE SAME TABLE OR | | PROVIDE CALCULATIONS FOR THE ACTUAL WINDOW SIZE BASED | | ON THE LOCATION (INTERIOR/END ZONE), MEAN ROOF HEIGHT | | AND BUILDING EXPOSURE. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | 6- SHEET 3.1: NEED TO SPECIFY TOP AND THE BOTTOM | | CONNECTORS AT THE STRUCTURAL FRAME MEMBERS OF THE | | SECTION AT WOOD FRAME IN-FILL DETAIL. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | 7- PRODUCT APPROVALS | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | A)OUTSWING ENTRY DOOR AND ENLARGED BEDROOM EXTERIOR | | DOOR AS SHOWN ON PLANS. | | DESIGN PRESSURES (+/- 35) SHOWN ON DOOR FLORIDA PRODUCT | | APPROVAL FL11861-R8 SUBMITTED DON'T MEET THE DESIGN | | PRESSURES REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. | | NEED TO PROVIDE PRODUCT APPROVAL FOR DOOR THAT MEETS | | THE CALCULATED DESIGN PRESSURES. NOTE: NEED TO | | COORDINATE WITH REVISED DESIGN PRESSURES ON ITEM #5 | | ABOVE. | | | | B)HURRICANE SHUTTERS IF DOORS/WINDOWS PRODUCT APPROVALS | | DON'T HAVE IMPACT GLAZING. | | NOTE: NEED TO PROVIDE ALSO A SHUTTERS COMPLETE | | INSTALLATION SCHEDULE AS REQUIRED BY CITY | | IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT | | PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY | | SAMPLE. | | | | C)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS (NOTE: | | INCLUDING THE ONES ALREADY SUBMITTED) AS REQUIRED BY | | SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 9- FLOOR PLANS AND ELEVATIONS STATE THAT THE NEW STAIRS | | TO THE SECOND FLOOR ARE TO BE DONE BY OTHERS. DESIGNER | | OF RECORD NEEDS TO PROVIDE THE DETAILS AND | | SPECIFICATIONS FOR THE CONSTRUCTION OF THE STAIRS. | | ALSO, DESIGNER OF RECORD NEEDS TO PROVIDE THE DETAILS | | AND SPECIFICATIONS FOR THE CONSTRUCTION OF THE | | HANDRAILS AND GUARDRAILS AS REQUIRED BY TABLE R301.5, | | SEC. R311.7.8 AND SEC. R312.1 FBC-RESIDENTIAL. | | NOTE: SUBSEQUENT HANDRAIL/GUARDRAIL SHOP DRAWINGS ARE | | TO CONFIRM THAT DESIGN DETAILS AND SPECIFICATIONS ARE | | MET. | | | | 10- ORIGINAL STAIRWAY WAS LOCATED IN THE MIDDLE OF THE | | BUILDING. NEW STAIRWAY IS LOCATED ON THE EXTERIOR SIDE | | OF THE BUILDING. ARCHITECT OF RECORD NEEDS TO SHOW HOW | | THE SECOND FLOOR WAS AFFECTED TO ALLOW THE NEW | | STAIRWAY. SHOW ALL REQUIRED CONSTRUCTION TO ALLOW NEW | | STAIRWAY TO SERVE THE SECOND FLOOR ENTRY TO THE | | APARTMENT. SHOW ALL EXTERIOR CONSTRUCTION SHOWN ON THE | | WEST ELEVATION. ON SHEET 2.1. SEC. 107.2.1 CITY | | AMENDMENTS. THIS WAS REMOVED TO ALLOW FOR FIRST FLOOR | | BEDROOM RECONSTRUCTION. | | | | 11- ROOF FRAMING PLAN AND TYPICAL WALL SECTION DON'T | | SPECIFY THE CONNECTION OF THE 2X12 ROOF JOIST. SPECIFY | | CONNECTOR. SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 12- TYPICAL WALL SECTION ON SHEET 3.1: | | A) SPECIFY CEILING INSULATION. SEC. R103.2.1 FBC-ENERGY | | CONSERVATION. | | | | B)SPECIFIED VENT 6"X26" SCREEN VENT AT 6'-0" DOESN'T | | PROVIDE CROSS VENTILATION. THIS IS A FLAT ROOF. REVISE | | AS REQUIRED. SEC. R806 FBC-RESIDENTIAL. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2021-06-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-06-24 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-06-24 |
Time |
13:35 |
Sent To |
|
|
Notes |
2021-06-24 15:44:41 | RESIDENTIAL (R3) ADDITION/ALTERATION, SIXTH BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT # 19100548 | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | ORIGINAL COMMENT: | | 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. 908 FBC-EXISTING BUILDING AND SEC. R101.5 | | FBC-ENERGY CONSERVATION. | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID | | CONFLICTS/DELAYS. | | | | RESPONSE: | | ENERGY CALCULATIONS SUBMITTED: | | | | NOTE: | | FORM R405-2020 SUBMITTED NOW IS THE WRONG FORM. THIS | | PROJECT IS REVIEWED UNDER THE 2017 CODE. PROVIDE | | CORRECT FORM R405-2017 AS DONE ON PREVIOUS SUBMITTAL. | | | | REPEAT COMMENT (THREE TIMES): | | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY | | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO | | BEGIN CONSTRUCTION. | | | | B) OK. | | C) OK. | | | | REPEAT COMMENT. | | D) REVISE THE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 | | TO MATCH PLANS. THIS IS FOR ENTIRE FIRST FLOOR. SEE | | PLANS/ELEVATIONS AND REVISE AS REQUIRED. CHECK WINDOWS | | OVERHANG AND SEPARATION ALSO. SEC. R101.5.1.1.2 | | FBC-ENERGY CONSERVATION. | | | | E)OK. | | | | REPEAT COMMENT. | | F)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE | | LEVEL (EPL) DISPLAY CARD SUBMITTED SEC. R405.4.3 FBC- | | ENERGY CONSERVATION. | | | | NEW COMMENTS: | | G) ITEM #3 IS INCORRECT. COORDINATE WITH ITEM 1(G) | | ABOVE AND REVISE AS REQUIRED. | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | 2- OK. | | 3- OK | | 4- OK. | | 5- OK. | | 6- OK | | | | ORIGINAL COMMENT. | | 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | | | A)EXTERIOR DOORS AS SHOWN ON PLANS. | | | | RESPONSE: | | REPEAT COMMENT. | | DESIGN PRESSURES (+/- 35) SHOWN ON DOOR FLORIDA PRODUCT | | APPROVAL FL11861-R8 SUBMITTED DON'T MEET THE DESIGN | | PRESSURES REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. | | NEED TO PROVIDE PRODUCT APPROVAL FOR DOOR THAT MEETS | | THE CALCULATED DESIGN PRESSURES. NOTE: NEED TO | | COORDINATE WITH REVISED DESIGN PRESSURES ON ITEM #5 | | ABOVE. | | | | B)OK | | | | C) HURRICANE SHUTTERS IF DOORS/WINDOWS PRODUCT | | APPROVALS DON'T HAVE IMPACT GLAZING. | | PROTECTION OF OPENINGS IS REQUIRED BY SEC. R301.2.1.2 | | FBC-RESIDENTIAL. SEC. 801.3 FBC-EXISTING BUILDING | | | | NOTE: NEED TO PROVIDE ALSO A SHUTTERS COMPLETE | | INSTALLATION SCHEDULE AS REQUIRED BY CITY | | IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT | | PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY | | SAMPLE | | | | REPEAT COMMENT: | | D) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 9- FLOOR PLANS AND ELEVATIONS STATE THAT THE NEW STAIRS | | TO THE SECOND FLOOR ARE TO BE DONE BY OTHERS. PROVIDE | | COMPLETE DETAILS AND SPECIFICATIONS FOR THIS STAIRWAY | | OR CLARIFY IF SUBMITTING THIS INFORMATION UNDER A | | SEPARATE PERMIT. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | RESPONSE: | | DESIGNER OF RECORD TO PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS OR INDICATE IF THIS WORK IS | | UNDER A SEPARATE PERMIT. | | | | 10- OK. | | | | 11- OK. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-03-12 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-03-11 |
Time |
17:41 |
Sent To |
|
|
Notes |
2021-03-12 12:05:42 | RESIDENTIAL (R3) ADDITION/ALTERATION, FIFTH BUILDING | | REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT # 19100548 | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | ORIGINAL COMMENT: | | 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. 908 FBC-EXISTING BUILDING AND SEC. R101.5 | | FBC-ENERGY CONSERVATION. | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID | | CONFLICTS/DELAYS. | | | | RESPONSE: | | ENERGY CALCULATIONS SUBMITTED: | | | | REPEAT COMMENT. | | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY | | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO | | BEGIN CONSTRUCTION. | | | | REPEAT COMMENT. | | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2 FBC- | | ENERGY CONSERVATION. | | | | REPEAT COMMENT. | | C) CONDITIONED FLOOR AREA ON ITEM #6 ON PAGE 1 OF 4 IS | | INCORRECT. IT DOESN'T MATCH PLANS. SEE PLANS AND REVISE | | AS REQUIRED. | | SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | REPEAT COMMENT. | | D) REVISE THE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 | | TO MATCH PLANS. THIS IS FOR ENTIRE FIRST FLOOR. SEE | | PLANS/ELEVATIONS AND REVISE AS REQUIRED. CHECK WINDOWS | | OVERHANG AND SEPARATION ALSO. SEC. R101.5.1.1.2 | | FBC-ENERGY CONSERVATION. | | | | E)ROOF TYPE AND MATERIAL SPECIFIED ON PAGE 3 OF 4 | | DOESN'T MATCH PLANS/ELEVATIONS. PLANS SHOW FLAT ROOF NO | | HIP. SEE PLANS AND REVISE AS REQUIRED. | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | F)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE | | LEVEL (EPL) DISPLAY CARD SUBMITTED SEC. R405.4.3 FBC- | | ENERGY CONSERVATION. | | | | 2- OK. | | 3- OK | | 4- OK. | | | | ORIGINAL COMMENT: | | 5- DOOR AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET 2.1 | | ARE TOO LOW IF THEY ARE DONE USING TABLE R301.2(2) | | FBC-RESIDENTIAL AS SPECIFIED ON PLANS. SEE TABLE | | R301.2(2) FBC-RESIDENTIAL AND REVISE AS REQUIRED. USE | | THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA AS | | REQUIRED BY FOOTNOTE "B" OF THE SAME TABLE OR PROVIDE | | CALCULATIONS FOR THE ACTUAL WINDOW SIZE BASED ON THE | | LOCATION (INTERIOR/END ZONE), MEAN ROOF HEIGHT AND | | BUILDING EXPOSURE. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | REVISE DESIGN PRESSURES AGAIN. PRESSURES GIVEN ARE | | TAKING FROM TABLE R301.2(2) FBC-RESIDENTIAL. THIS | | BUILDING IS IN EXPOSURE "C". NEED TO MULTIPLE PRESSURES | | BY COEFFICIENT SHOWN ON TABLE R301.2(3) FBC-RESIDENTIAL | | BASED ON THE HEIGHT OF THE BUILDING. REVISE AS | | REQUIRED. NOTE: THIS IS A TWO STORY BUILDING. | | | | 6- OK | | | | ORIGINAL COMMENT. | | 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL) | | | | A)EXTERIOR DOORS AS SHOWN ON PLANS. | | | | RESPONSE: | | DESIGN PRESSURES (+/- 35) SHOWN ON DOOR FLORIDA PRODUCT | | APPROVAL FL11861-R8 SUBMITTED DON'T MEET THE DESIGN | | PRESSURES REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. | | NEED TO PROVIDE PRODUCT APPROVAL FOR DOOR THAT MEETS | | THE CALCULATED DESIGN PRESSURES. NOTE: NEED TO | | COORDINATE WITH REVISED DESIGN PRESSURES ON ITEM #5 | | ABOVE. | | | | B)SINGLE HUNG WINDOWS. OK | | | | C) HURRICANE SHUTTERS IF DOORS/WINDOWS PRODUCT | | APPROVALS DON'T HAVE IMPACT GLAZING. | | PROTECTION OF OPENINGS IS REQUIRED BY SEC. R301.2.1.2 | | FBC-RESIDENTIAL. SEC. 801.3 FBC-EXISTING BUILDING | | | | RESPONSE: | | SWING DOOR PRODUCT APPROVAL SUBMITTED DON'T HAVE IMPACT | | GLAZING. COORDINATE WITH ITEM # 7.A) ABOVE. | | | | NOTE: NEED TO PROVIDE ALSO A SHUTTERS COMPLETE | | INSTALLATION SCHEDULE AS REQUIRED BY CITY | | IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT | | PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY | | SAMPLE | | | | D) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AT ALL. CONTRACTOR DIDN'T | | EVEN SPECIFIED IF SUBMITTING LATER AS A DEFERRED | | SUBMITTAL. | | | | 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 9- FLOOR PLANS AND ELEVATIONS STATE THAT THE NEW STAIRS | | TO THE SECOND FLOOR ARE TO BE DONE BY OTHERS. PROVIDE | | COMPLETE DETAILS AND SPECIFICATIONS FOR THIS STAIRWAY | | OR CLARIFY IF SUBMITTING THIS INFORMATION UNDER A | | SEPARATE PERMIT. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 10- ALL DRAWINGS SUBMITTED ARE NOT SIGNED AND SEALED BY | | THE ARCHITECT OF RECORD. ARCHITECT TO SIGN AND SEAL | | DRAWING AS REQUIRED BY 61G1-16.001FAC AND CHAPTER 481 | | F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC | | RECORDS. | | | | NOTE: PLANS MAY BE SUBMITTED WITH A DIGITAL SIGNATURE | | OR HARD COPIES WITH LICENSED DESIGN PROFESSIONAL SEAL | | AND SIGNATURE MAY BE DROPPED (OR MAILED) TO CITY HALL | | FOR RECORDS RETENTION. | | | | 11- ARCHITECT TO REVISE TYPICALLY WALL SECTION ON SHEET | | 3.1. | | SCREEN VENTS SPACED AT 6'-0" O.C. DON'T PROVIDE CROSS | | VENTILATION AS REQUIRED BY SEC. R806 FBC-RESIDENTIAL. | | THIS IS A FLAT ROOF WITH SOLID 2X12 ROOF JOISTS. | | TYPICALLY, A CONTINUOUS VENT IS INSTALLED IN THIS TYPE | | OF ROOFS. REVISE AS REQUIRED. SPECIFY VENT TYPE AND | | SIZE THAT WILL PROVIDE REQUIRED CROSS VENTILATION. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2020-09-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-29 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-29 |
Time |
11:39 |
Sent To |
|
|
Notes |
2020-09-29 13:36:57 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC 2014 | | | | 4TH REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | BELOW ARE THE COMMENTS FROM THE 2ND REVIEW. NO 3RD | | REVIEW WAS PERFORMED DUE TO FEES NOT BEING PAID. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | PREVIOUS COMMENTS. | | | | | | RESIDENTIAL (R3) ALTERATION LEVEL 3, SECOND BUILDING | | REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES APPLY. CONTRACTOR TO | | ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME OR | | IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | ISSUANCE. | | | | ****IMPORTANT***** | | ENERGY CALCULATIONS NEED TO BE SIGNED/DATED BY THE | | OWNER PRIOR TO PASSING THE BUILDING REVIEW WITH | | PROVISO. | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. 908 FBC-EXISTING BUILDING AND SEC. R101.5 | | FBC-ENERGY CONSERVATION. | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID | | CONFLICTS/DELAYS. | | | | RESPONSE: | | ENERGY CALCULATIONS SUBMITTED: | | | | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY | | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO | | BEGIN CONSTRUCTION. | | | | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2 FBC- | | ENERGY CONSERVATION. | | | | C) ITEM #1 ON PAGE 1 OF 4 IS INCORRECT. THIS IS NOT NEW | | CONSTRUCTION. THIS IS EXISTING BUILDING. REVISE AS | | REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | D) CONDITIONED FLOOR AREA ON ITEM #6 ON PAGE 1 OF 4 IS | | INCORRECT. REVISE AS REQUIRED. CLARIFY WHY THE AREAS | | DON'T MATCH AREAS SHOWN ON THE PROPERTY APPRAISER | | WEBSITE IF THE FOOTPRINT SEEMS TO BE THE SAME. SEC. | | R101.5.1.1.2 FBC-RESIDENTIAL. | | | | E) REVISE THE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 | | TO MATCH PLANS. REVISE OVERHANG DEPTH AND SEPARATION TO | | MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | NEW COMMENT: 4TH REVIEW | | | | ENERGY SUBMITTAL MISSING FROM SUBMITTAL. | | | | 2- OK. | | | | 3- OK | | | | 4- OK. | | | | 5- DOOR AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET 2.1 | | ARE TOO LOW IF THEY ARE DONE USING TABLE R301.2(2) | | FBC-RESIDENTIAL AS SPECIFIED ON PLANS. SEE TABLE | | R301.2(2) FBC-RESIDENTIAL AND REVISE AS REQUIRED. USE | | THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA AS | | REQUIRED BY FOOTNOTE "B" OF THE SAME TABLE OR PROVIDE | | CALCULATIONS FOR THE ACTUAL WINDOW SIZE BASED ON THE | | LOCATION (INTERIOR/END ZONE), MEAN ROOF HEIGHTT AND | | BUILDING EXPOSURE. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | RESPONSE: | | REVISE DESIGN PRESSURES AGAIN. PRESSURES GIVEN ARE | | TAKING FROM TABLE R301.2(2) FBC-RESIDENTIAL. THIS TABLE | | IS BASED ON BUILDING EXPOSURE "B". THIS BUILDING IS IN | | EXPOSURE "C". NEED TO MULTIPLE PRESSURES BY COEFFICIENT | | SHOWN ON TABLE R301.2(3) FBC-RESIDENTIAL BASED ON THE | | HEIGH OF THE BUILDING.. REVISE AS REQUIRED. NOTE: THIS | | IS A TWO STORY BUILDING. | | | | NEW COMMENT: 4TH REVIEW | | | | PRESSURES FROM TABLE R301.2(2) HAVE NOT BEEN ADJUSTED | | BY CO-EFFIEIENT SHOWN ON TABLE R301.2(3) | | | | 6- OK | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL) | | | | A)EXTERIOR DOORS AS SHOWN ON PLANS. | | NOTE: NOA 16-0617.02 SUBMITTED IS FOR SLIDING GLASS | | DOORS. THERE ARE NOT SLIDING GLASS DOORS ON THIS | | PROJECT. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T | | SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL. | | | | B)SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T | | SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL. | | | | C) HURRICANE SHUTTERS IF DOORS/WINDOWS PRODUCT | | APPROVALS DON'T HAVE IMPACT GLAZING. | | PROTECTION OF OPENINGS IS REQUIRED BY SEC. R301.2.1.2 | | FBC-RESIDENTIAL. SEC. 801.3 FBC-EXISTING BUILDING | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T | | SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL. | | | | NOTE: NEED TO PROVIDE ALSO A SHUTTERS COMPLETE | | INSTALLATION SCHEDULE AS REQUIRED BY CITY | | IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT | | PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY | | SAMPLE | | | | D) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | (INCLUDING THE ONES ALREADY SUBMITTED) AS REQUIRED BY | | SEC. 107.3.4.1 CITY AMENDMENTS. | | | | NEW COMMENT: 4TH REVIEW | | | | PRODUCT APPROVALS ARE MISSING FROM SUBMITTAL | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-01-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-01-14 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-01-14 |
Time |
11:14 |
Sent To |
|
|
Notes |
2020-01-14 11:30:36 | PLAN REVIEW FEES ARE NO PAID. REVIEW NO DONE. UNTIL | | FEES ARE PAID. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-12-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-10 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-10 |
Time |
10:15 |
Sent To |
|
|
Notes |
2019-12-10 10:47:23 | RESIDENTIAL (R3) ALTERATION LEVEL 3, SECOND BUILDING | | REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | PERMIT # 19100548 | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES APPLY. CONTRACTOR TO | | ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME OR | | IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | ISSUANCE. | | | | ****IMPORTANT***** | | ENERGY CALCULATIONS NEED TO BE SIGNED/DATED BY THE | | OWNER PRIOR TO PASSING THE BUILDING REVIEW WITH | | PROVISO. | | | | | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | | | 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. 908 FBC-EXISTING BUILDING AND SEC. R101.5 | | FBC-ENERGY CONSERVATION. | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID | | CONFLICTS/DELAYS. | | | | RESPONSE: | | ENERGY CALCULATIONS SUBMITTED: | | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED | | AND DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY | | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO | | BEGIN CONSTRUCTION. | | | | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2 FBC- | | ENERGY CONSERVATION. | | | | C) ITEM #1 ON PAGE 1 OF 4 IS INCORRECT. THIS IS NOT NEW | | CONSTRUCTION. THIS IS EXISTING BUILDING. REVISE AS | | REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | D) CONDITIONED FLOOR AREA ON ITEM #6 ON PAGE 1 OF 4 IS | | INCORRECT. REVISE AS REQUIRED. CLARIFY WHY THE AREAS | | DON'T MATCH AREAS SHOWN ON THE PROPERTY APPRAISER | | WEBSITE IF THE FOOTPRINT SEEMS TO BE THE SAME. SEC. | | R101.5.1.1.2 FBC-RESIDENTIAL. | | | | E) REVISE THE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 | | TO MATCH PLANS. REVISE OVERHANG DEPTH AND SEPARATION TO | | MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | 2- OK. | | | | 3- OK | | | | 4- OK. | | | | 5- DOOR AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET 2.1 | | ARE TOO LOW IF THEY ARE DONE USING TABLE R301.2(2) | | FBC-RESIDENTIAL AS SPECIFIED ON PLANS. SEE TABLE | | R301.2(2) FBC-RESIDENTIAL AND REVISE AS REQUIRED. USE | | THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA AS | | REQUIRED BY FOOTNOTE "B" OF THE SAME TABLE OR PROVIDE | | CALCULATIONS FOR THE ACTUAL WINDOW SIZE BASED ON THE | | LOCATION (INTERIOR/END ZONE), MEAN ROOF HEIGHTT AND | | BUILDING EXPOSURE. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | RESPONSE: | | REVISE DESIGN PRESSURES AGAIN. PRESSURES GIVEN ARE | | TAKING FROM TABLE R301.2(2) FBC-RESIDENTIAL. THIS TABLE | | IS BASED ON BUILDING EXPOSURE "B". THIS BUILDING IS IN | | EXPOSURE "C". NEED TO MULTIPLE PRESSURES BY COEFFICIENT | | SHOWN ON TABLE R301.2(3) FBC-RESIDENTIAL BASED ON THE | | HEIGH OF THE BUILDING.. REVISE AS REQUIRED. NOTE: THIS | | IS A TWO STORY BUILDING. | | | | 6- OK | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL) | | | | | | A)EXTERIOR DOORS AS SHOWN ON PLANS. | | NOTE: NOA 16-0617.02 SUBMITTED IS FOR SLIDING GLASS | | DOORS. THERE ARE NOT SLIDING GLASS DOORS ON THIS | | PROJECT. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T | | SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL. | | | | B)SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T | | SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL. | | | | C) HURRICANE SHUTTERS IF DOORS/WINDOWS PRODUCT | | APPROVALS DON'T HAVE IMPACT GLAZING. | | PROTECTION OF OPENINGS IS REQUIRED BY SEC. R301.2.1.2 | | FBC-RESIDENTIAL. SEC. 801.3 FBC-EXISTING BUILDING | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR DIDN'T | | SPECIFIED IF SUBMITTING LATER AS A DEFERRED SUBMITTAL. | | | | NOTE: NEED TO PROVIDE ALSO A SHUTTERS COMPLETE | | INSTALLATION SCHEDULE AS REQUIRED BY CITY | | IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT | | PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY | | SAMPLE | | | | NEW COMMENT BASED ON REVISED PLANS. | | D) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | (INCLUDING THE ONES ALREADY SUBMITTED) AS REQUIRED BY | | SEC. 107.3.4.1 CITY AMENDMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-10-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-24 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-24 |
Time |
09:14 |
Sent To |
|
|
Notes |
2019-10-24 17:27:05 | RESIDENTIAL (R3) ALTERATION LEVEL 3, BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | | | 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | BY SEC. 908 FBC-EXISTING BUILDING AND SEC. R101.5 | | FBC-ENERGY CONSERVATION. | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID | | CONFLICTS/DELAYS. | | | | 2- PLANS SHOW REMOVING ONE EXTERIOR DOOR FROM THE | | BEDROOM. NONE OF THE PROPOSED WINDOWS SEEM TO COMPLY | | WITH THE EGRESS REQUIREMENTS. SEC. 702.5 FBC-BUILDING. | | REVISE AS REQUIRED. AND, CLEARLY SPECIFY THE ACTUAL | | SIZE OF THE PROPOSED EGRESS WINDOW AND PROVIDE | | MANUFACTURER'S CUT SHEETS SHOWING THAT THE SPECIFIED | | WINDOW COMPLIES WITH ALL THE EGRESS REQUIREMENTS. | | | | 3- SHEET 1.1: | | A)BASED ON DRAWINGS SUBMITTED, THIS IS AN ALTERATION | | LEVEL 3 NOT LEVEL 2. SEE SEC. 505 FBC-EXISTING | | BUILDING. REVISE INFORMATION GIVEN UNDER "PROJECT | | DATA". | | | | B) REVISE THE "PLYWOOD SHEATHING NAILING SCHEDULE". | | NEED TO SPECIFY RING SHANK NAILS AS REQUIRED BY SEC. | | 801.3 FBC-EXISTING BUILDING AND SEC. R803.2.3.1 | | FBC-RESIDENTIAL. | | NOTE: NEED TO COORDINATE THIS INFORMATION WITH | | INFORMATION SHOWN ON THE "TYPICAL WOOD FRAME WALL | | SECTION" ON SHEET 3.1 TO AVOID CONFLICTS/DELAYS. | | | | C) REVISE THE "A" DIMENSION SPECIFIED ON THE PLAN SHOWN | | ABOVE THE "PLYWOOD SHEATHING NAILING SCHEDULE". NEED TO | | SPECIFY 4 FEET MIN. AS REQUIRED BY FIGURE R301.2(7) | | FBC-RESIDENTIAL AND SEC. 801.3 FBC-EXISTING BUILDING | | | | 4- PLANS SHOW NEW ROOF WITH A ROOF PITCH OF 2.5 PER | | FOOT. NEED TO SPECIFY TWO LAYERS OF UNDERLAYMENT AS | | REQUIRED BY SEC. R905.2.2 FBC-RESIDENTIAL. SEC. 801.3 | | FBC-EXISTING BUILDING | | | | 5- DOOR AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET 2.1 | | ARE TOO LOW IF THEY ARE DONE USING TABLE R301.2(2) | | FBC-RESIDENTIAL AS SPECIFIED ON PLANS. SEE TABLE | | R301.2(2) FBC-RESIDENTIAL AND REVISE AS REQUIRED. USE | | THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA AS | | REQUIRED BY FOOTNOTE "B" OF THE SAME TABLE OR PROVIDE | | CALCULATIONS FOR THE ACTUAL WINDOW SIZE BASED ON THE | | LOCATION (INTERIOR/END ZONE), MEAN ROOF HEIGHT AND | | BUILDING EXPOSURE. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | 6- SHEET 3.1: | | A) NEED TO SPECIFY ALL THE CONNECTORS AT THE BOTTOM OF | | ALL STRUCTURAL FRAME MEMBERS OF THE TYPICAL WINDOW | | OPENING IN FRAME WALL DETAIL. SEC. 801.3 FBC-EXISTING | | BUILDING. SEC. R301.1 FBC-RESIDENTIAL. | | | | B) NEED TO SPECIFY ALL THE CONNECTORS AT THE STRUCTURAL | | FRAME MEMBERS OF THE SECTION AT WOOD FRAME IN-FILL | | DETAIL. SEC. 801.3 FBC-EXISTING BUILDING. SEC. R301.1 | | FBC-RESIDENTIAL. | | NOTE: CLARIFY/REVISE THE FINISH MATERIALS ON THE | | INTERIOR AND EXTERIOR SIDE OF THE WALL. DETAIL PROVIDE | | IS SPECIFYING 5/8" DRYWALL ON BOTH SIDES. REVISE AS | | REQUIRED. | | | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | | | A)EXTERIOR DOORS AS SHOWN ON PLANS. | | NOTE: NOA 16-0617.02 SUBMITTED IS FOR SLIDING GLASS | | DOORS. THERE ARE NOT SLIDING GLASS DOORS ON THIS | | PROJECT. | | | | B)SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | | C) HURRICANE SHUTTERS IF DOORS/WINDOWS PRODUCT | | APPROVALS DON'T HAVE IMPACT GLAZING. | | PROTECTION OF OPENINGS IS REQUIRED BY SEC. R301.2.1.2 | | FBC-RESIDENTIAL. SEC. 801.3 FBC-EXISTING BUILDING | | | | NOTE: NEED TO PROVIDE ALSO A SHUTTERS COMPLETE | | INSTALLATION SCHEDULE AS REQUIRED BY CITY | | IMPLEMENTATION STANDARD FOR WIND-BORNE DEBRIS IMPACT | | PROTECTION FOR THE FLORIDA BUILDING CODE. SEE CITY | | SAMPLE | | | | | | 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | (INCLUDING THE ONES ALREADY SUBMITTED) AS REQUIRED BY | | SEC. 107.3.4.1 CITY AMENDMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-08-15 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-08-15 |
Time |
11:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-06-16 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-06-16 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2021-03-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-03-15 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-03-15 |
Time |
16:33 |
Sent To |
|
|
Notes |
2021-03-15 16:39:50 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | ALL ELECTRICAL PAGES ARE LOCKED I CAN NOT REVIEW A | | LOCKED PAGE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-09-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-09-21 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-09-21 |
Time |
12:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-12-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-12-20 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-12-20 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-10-31 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-10-31 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-10-31 |
Time |
06:37 |
Sent To |
|
|
Notes |
2019-10-31 14:20:31 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PERMIT APPLICATION STATES THIS IS A FULL RENOVATION. | | THERE ARE NO ELECTRICAL PLANS FOR THE SECOND FLOOR. | | PROVIDE FULL SET OF PLANS FOR REVIEW. WPB FBC 107.2.1 | | 2. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1, | | 801.2, OR 901.2 AS APPLICABLE. | | 3. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | R314.3(4), NFPA 72:29.8.3.4 | | 4. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
N |
Date |
2022-08-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-08-08 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-08-08 |
Time |
07:08 |
Sent To |
|
|
Notes |
2022-08-08 07:24:05 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2021-06-22 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-06-22 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-06-22 |
Time |
14:39 |
Sent To |
|
|
Notes |
2021-06-22 14:40:04 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | SEC. 105.1. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2021-03-16 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-03-16 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-03-16 |
Time |
17:34 |
Sent To |
|
|
Notes |
2021-03-16 17:35:43 | SEPERATE GAS PERMIT REQUIRED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-08-15 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-08-02 |
Time |
16:11 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2021-06-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-06-24 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-06-08 |
Time |
13:00 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2021-03-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-03-17 |
Time |
07:11 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-03-08 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-09-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-29 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-15 |
Time |
14:36 |
Sent To |
|
|
Notes |
2020-01-21 08:42:59 | VERIFY PLAN REVIEW FEES ARE PAID PRIOR TO ROUTING FOR | | REVIEW S.HILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-01-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-01-14 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-01-03 |
Time |
13:23 |
Sent To |
I |
|
Notes |
2020-01-06 13:23:55 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-12-20 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-12-05 |
Time |
15:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-10-31 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-10-10 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-08-15 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-08-15 |
Time |
09:15 |
Sent To |
|
|
Notes |
2022-08-15 09:15:58 | IMPACT FEES | | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2021-06-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-06-24 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-06-24 |
Time |
15:48 |
Sent To |
|
|
Notes |
2021-06-24 15:49:32 | IMPACT FEES | | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-08-09 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-08-09 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-16 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-16 |
Time |
10:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2021-03-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-03-10 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-03-10 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2020-09-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-17 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-17 |
Time |
07:37 |
Sent To |
|
|
Notes |
2020-09-17 07:45:27 | PLEASE RESPOND TO COMMENTS FOR 3RD REVIEW DATED | | 09/16/2020. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-16 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-16 |
Time |
13:15 |
Sent To |
|
|
Notes |
2020-09-16 13:52:28 | PLEASE SEE 1ST CYCLE MECHANICAL REVIEWERS NOTES. I DO | | NOT SEE THE INFORMATION ASKED FOR IN CYCLE 1 REVIEW. | | PLEASE SUBMIT THE ENERGY AND MECHANICAL UNIT SIZING | | CALCULATIONS. PLEASE ALSO PROVIDE SPECIFICATIOONS FOR | | THE MINI SPLIT SYSTEMS. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-12-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-10 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-10 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-10-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-24 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-24 |
Time |
17:48 |
Sent To |
|
|
Notes |
2019-10-24 17:50:22 | RESIDENTIAL (R3) ALTERATION LEVEL 3 MECHANICAL REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- PROVIDE COMPLETE EQUIPMENT LOAD CALCULATIONS. SEC. | | 801.3 FBC-EXISTING BUILDING AND SEC. R403.7 FBC-ENERGY | | CONSERVATION. | | NOTE: SPECIFY THE EQUIPMENT MANUFACTURER AND MODEL AS | | REQUIRED BY SEC. R403.7.1 FBC-ENERGY CONSERVATION. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
P |
Date |
2022-08-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-08-08 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-08-08 |
Time |
06:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2021-06-22 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2021-06-22 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2021-06-22 |
Time |
14:40 |
Sent To |
|
|
Notes |
2021-06-22 14:40:29 | 06/22/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2021-03-16 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-03-16 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-03-16 |
Time |
17:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2020-09-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-09-21 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-09-21 |
Time |
09:59 |
Sent To |
|
|
Notes |
2020-09-21 09:59:48 | 09/21/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-09-16 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-09-16 |
Time |
08:27 |
Sent To |
|
|
Notes |
2020-09-16 08:28:46 | 09/16/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-12-19 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-12-19 |
Time |
14:57 |
Sent To |
|
|
Notes |
2019-12-19 14:57:11 | PLUMBING COMMENTS: APPROVED | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-10-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-10-22 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-10-22 |
Time |
08:15 |
Sent To |
|
|
Notes |
2019-10-22 13:47:15 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. PROVIDE DETAILED SCOPE OF PLUMBING WORK BEING DONE | | PLAN IS UNCLEAR. PER WPB AMEND TO FBC 107.2.1 | | | | 2. BY INCLUDING THE SANITARY ISOMETRIC DRAWING IT | | APPEARS THAT THE SANITARY PIPING SYSTEM IS BEING | | REPLACED IF YOU ONLY MOVING THE TOILET A ISOMETRIC | | DRAWING IS NOT REQUIRED PLEASE CORRECT THE FOLLOWING | | CODE VIOLATIONS ON THE ISOMETRIC. | | A)THE KITCHEN BRANCH DRAIN CAN NOT CONNECT TO BATHROOM | | GROUP SHALL CONNECT DOWN STREAM. PER FBC RES P3108.1 | | B)SHOWER SHALL CONNECT TO BATHROOM GROUP AND BE VENTED | | BY LAVATORY OR BE INDIVIDUALLY VENTED.PER FBC RES | | P3108.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
6 |
Status |
F |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-08-15 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-08-15 |
Time |
13:51 |
Sent To |
|
|
Notes |
2022-08-15 13:52:49 | ROOFING REVIEW: | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | ************************ | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
F |
Date |
2021-06-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-06-24 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-06-24 |
Time |
15:49 |
Sent To |
|
|
Notes |
2021-06-24 15:50:43 | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | ************************ | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-03-12 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-03-12 |
Time |
11:47 |
Sent To |
|
|
Notes |
2021-03-12 11:50:59 | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL) | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED AT ALL. CONTRACTOR DIDN'T | | EVEN SPECIFIED IF SUBMITTING LATER AS A DEFERRED | | SUBMITTAL. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | ************************ | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2020-09-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-29 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-29 |
Time |
13:43 |
Sent To |
|
|
Notes |
2020-09-29 13:44:51 | PLAN REVIEW / BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC 2014 | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PRODUCT APPROVALS ARE MISSING FROM | | SUBMITTAL. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-12-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-20 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-20 |
Time |
14:24 |
Sent To |
|
|
Notes |
2019-12-20 14:24:37 | OWENS CORNING SHINGLES NOA 17-1211.02. | | | | TAMKO UNDERLAYMENT NOA 17-0531.01 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2019-10-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-24 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-24 |
Time |
17:22 |
Sent To |
|
|
Notes |
2019-10-24 17:24:59 | OWENS CORNING SHINGLES NOA 17-1211.02. | | | | TAMKO UNDERLAYMENT NOA 17-0531.01 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-08-09 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-08-09 |
Time |
10:51 |
Sent To |
|
|
Notes |
2022-08-09 13:01:22 | HARD COPY DRAWINGS 1.1, 2.1, 3.1 AND 4.1 HAVE | | ARCHITECT'S EMBOSSED SEAL AND WET SIGNATURE. DRAWING | | C.1 HAS DIGITAL SIGNATURE. JG. | 2022-08-09 10:13:36 | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-06-16 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-06-16 |
Time |
10:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-03-12 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-03-12 |
Time |
11:46 |
Sent To |
|
|
Notes |
2021-03-12 11:07:36 | 1-SURVEY NEEDS SEAL/SIGNATURE. | | | | 2- ALL DRAWINGS SUBMITTED ARE NOT SIGNED AND SEALED BY | | THE ARCHITECT OF RECORD. ARCHITECT TO SIGN AND SEAL | | DRAWING AS REQUIRED BY 61G1-16.001FAC AND CHAPTER 481 | | F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC | | RECORDS. | | | | NOTE: PLANS MAY BE SUBMITTED WITH A DIGITAL SIGNATURE | | OR HARD COPIES WITH LICENSED DESIGN PROFESSIONAL SEAL | | AND SIGNATURE MAY BE DROPPED (OR MAILED) TO CITY HALL | | FOR RECORDS RETENTION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-09-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-09-29 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-09-29 |
Time |
11:39 |
Sent To |
|
|
Notes |
2020-09-29 13:42:35 | PLAN REVIEW / SIGNATURES | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A DIGITAL SIGNATURE OF THE DESIGN | | PROFESSIONAL IS REQUIRED. | | | | EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF | | (OR MAIL) ONE PAPER ORIGINAL WITH A WET SEAL AND | | SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
7 |
Status |
F |
Date |
2022-08-12 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2022-08-12 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2022-08-12 |
Time |
|
Sent To |
|
|
Notes |
2022-08-12 14:57:49 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE VALUE OF THE CONSTRUCTION ($60,000) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($106,046) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | [10/11/2019, 12/16/2019, 1/8/2020, 9/8/2020, 3/12/2021 | | AND 6/22/2021 REPEAT COMMENT - PLEASE NOTE THAT A | | LANDSCAPE PERMIT MUST BE SUBMITTED PRIOR TO ZONING'S | | APPROVAL OF THIS PERMIT. THIS COMMENT HAS NOT BEEN | | ADDRESSED ON MULTIPLE REVIEWS.] | | | | | | NOTES: | | | | * VOICE MESSAGE LEFT FOR KRISTEN CASTANO OF ACTION | | CONSTRUCTION GROUP AND FOLLOW UP EMAIL MADE TO | | [email protected] TO NOTIFY CONTRACTOR OF REQUIREMENT | | FOR A LANDSCAPE PERMIT PRIOR ZONING APPROVAL BACK ON | | 3/2021. | | | | * LANDSCAPE PERMIT REQUIRED PRIOR TO ZONING APPROVAL - | | HOLD PLACED ON THE C.O. | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * GREEN CARD #7-191 (3 UNITS = 1 RESIDENCE (SOUTH | | BUILDING) + DUPLEX (NORTH BUILDING)). | | | | *SCOPE OF WORK: INTERIOR RENOVATIONS AND INFILL/REPLACE | | WINDOWS AND/OR DOORS TO NORTH BUILDING (DUPLEX) ON | | FIRST FLOOR ONLY. | | . | | * ZONE: SF7 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
F |
Date |
2021-06-22 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2021-06-22 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2021-06-22 |
Time |
|
Sent To |
|
|
Notes |
2021-06-22 16:31:29 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE VALUE OF THE CONSTRUCTION ($60,000) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($106,046) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | [10/11/2019, 12/16/2019, 1/8/2020, 9/8/2020 AND | | 3/12/2021 REPEAT COMMENT - PLEASE NOTE THAT A LANDSCAPE | | PERMIT MUST BE SUBMITTED PRIOR TO ZONING'S APPROVAL OF | | THIS PERMIT. THIS COMMENT HAS NOT BEEN ADDRESSED ON | | MULTIPLE REVIEWS.] | | | | | | NOTES: | | | | * VOICE MESSAGE LEFT FOR KRISTEN CASTANO OF ACTION | | CONSTRUCTION GROUP AND FOLLOW UP EMAIL MADE TO | | [email protected] TO NOTIFY CONTRACTOR OF REQUIREMENT | | FOR A LANDSCAPE PERMIT PRIOR ZONING APPROVAL BACK ON | | 3/2021. | | | | * LANDSCAPE PERMIT REQUIRED PRIOR TO ZONING APPROVAL - | | HOLD PLACED ON THE C.O. | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * GREEN CARD #7-191 (3 UNITS = 1 RESIDENCE (SOUTH | | BUILDING) + DUPLEX (NORTH BUILDING)). | | | | *SCOPE OF WORK: INTERIOR RENOVATIONS AND INFILL/REPLACE | | WINDOWS AND/OR DOORS TO NORTH BUILDING (DUPLEX) ON | | FIRST FLOOR ONLY. | | . | | * ZONE: SF7 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2021-03-12 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2021-03-12 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
llouie |
Date |
2021-03-12 |
Time |
09:11 |
Sent To |
|
|
Notes |
2021-03-12 09:12:35 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE VALUE OF THE CONSTRUCTION ($60,000) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($106,046) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | [10/11/2019, 12/16/2019, 1/8/2020 AND 9/8/2020 REPEAT | | COMMENT - PLEASE NOTE THAT A LANDSCAPE PERMIT MUST BE | | SUBMITTED PRIOR TO ZONING'S APPROVAL OF THIS PERMIT. | | THIS COMMENT HAS NOT BEEN ADDRESSED ON MULTIPLE | | REVIEWS.] | | | | | | NOTES: | | | | * VOICE MESSAGE LEFT FOR KRISTEN CASTANO OF ACTION | | CONSTRUCTION GROUP AND FOLLOW UP EMAIL MADE TO | | [email protected] TO NOTIFY CONTRACTOR OF REQUIREMENT | | FOR A LANDSCAPE PERMIT PRIOR ZONING APPROVAL. | | | | * LANDSCAPE PERMIT REQUIRED PRIOR TO ZONING APPROVAL - | | HOLD PLACED ON THE C.O. | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * GREEN CARD #7-191 (3 UNITS = 1 RESIDENCE (SOUTH | | BUILDING) + DUPLEX (NORTH BUILDING)). | | | | *SCOPE OF WORK: INTERIOR RENOVATIONS AND INFILL/REPLACE | | WINDOWS AND/OR DOORS TO NORTH BUILDING (DUPLEX) ON | | FIRST FLOOR ONLY. | | . | | * ZONE: SF7 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2020-09-18 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-09-18 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-09-18 |
Time |
|
Sent To |
|
|
Notes |
2020-09-18 12:55:39 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE VALUE OF THE CONSTRUCTION ($60,000) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($106,046) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | [10/11/2019, 12/16/2019 AND 1/8/2020 REPEAT COMMENT - | | PLEASE NOTE THAT A LANDSCAPE PERMIT MUST BE SUBMITTED | | PRIOR TO ZONING'S APPROVAL OF THIS PERMIT] | | | | | | NOTES: | | | | * VOICE MESSAGE LEFT FOR KRISTEN CASTANO OF ACTION | | CONSTRUCTION GROUP AND FOLLOW UP EMAIL MADE TO | | [email protected] TO NOTIFY CONTRACTOR OF REQUIREMENT | | FOR A LANDSCAPE PERMIT PRIOR ZONING APPROVAL. | | | | * LANDSCAPE PERMIT REQUIRED PRIOR TO ZONING APPROVAL - | | HOLD PLACED ON THE C.O. | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * GREEN CARD #7-191 (3 UNITS = 1 RESIDENCE (SOUTH | | BUILDING) + DUPLEX (NORTH BUILDING)). | | | | *SCOPE OF WORK: INTERIOR RENOVATIONS AND INFILL/REPLACE | | WINDOWS AND/OR DOORS TO NORTH BUILDING (DUPLEX) ON | | FIRST FLOOR ONLY. | | . | | * ZONE: SF7 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2020-01-08 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-01-08 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-01-08 |
Time |
|
Sent To |
B |
|
Notes |
2020-01-08 09:18:12 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE VALUE OF THE CONSTRUCTION ($60,000) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($106,046) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. [10/11/2019 AND | | 12/16/2019 REPEAT COMMENT - PLEASE NOTE THAT A | | LANDSCAPE PERMIT MUST BE SUBMITTED PRIOR TO ZONING'S | | APPROVAL OF THIS PERMIT] | | | | | | NOTES: | | | | * VOICE MESSAGE LEFT FOR KRISTEN CASTANO OF ACTION | | CONSTRUCTION GROUP AND FOLLOW UP EMAIL MADE TO | | [email protected] TO NOTIFY CONTRACTOR OF REQUIREMENT | | FOR A LANDSCAPE PERMIT PRIOR ZONING APPROVAL. | | | | * LANDSCAPE PERMIT REQUIRED PRIOR TO ZONING APPROVAL - | | HOLD PLACED ON THE C.O. | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * GREEN CARD #7-191 (3 UNITS = 1 RESIDENCE (SOUTH | | BUILDING) + DUPLEX (NORTH BUILDING)). | | | | *SCOPE OF WORK: INTERIOR RENOVATIONS AND INFILL/REPLACE | | WINDOWS AND/OR DOORS TO NORTH BUILDING (DUPLEX) ON | | FIRST FLOOR ONLY. | | . | | * ZONE: SF7 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2019-12-16 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-12-16 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2019-12-13 |
Time |
|
Sent To |
|
|
Notes |
2019-12-16 10:12:14 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) UPDATED SIGNED AND SEALED SURVEY OF THE PROPERTY IS | | MISSING FROM THE APPLICATION. PLEASE PROVIDE. | | [10/11/2019 REPEAT COMMENT] | | | | 2.) SCOPE OF WORK SPECIFIES "FULL RENOVATION," BUT IT | | DOES NOT SPECIFY WHICH BUILDING ON THE PROPERTY IS | | SUBJECT TO THE SCOPE OF WORK. PLEASE ADDRESS IN WRITING | | AND IN THE REQUIRED SITE PLAN. [10/11/2019 MODIFIED | | COMMENT] | | | | 3.) PROJECT LOCATION MAP IS NOT CORRECT ON SHEET C.1. | | [10/11/2019 MODIFIED COMMENT] | | | | 4.) PROVIDE A SITE PLAN SHOWING ALL EXISTING AND | | PROPOSED (I.E. A/C UNIT) STRUCTURES ON THE PROPERTY. | | PLEASE NOTE THAT THE SETBACK DIMENSIONS FROM ALL | | PROPOSED NEW STRUCTURES SHALL ALSO BE PROVIDED IN THE | | SITE PLAN. [10/11/2019 REPEAT COMMENT] | | | | 5.) THE PROJECT DATA ON SHEET 1.1 INDICATES THAT THERE | | IS A COVERED PATIO, BUT IT IS NOT ILLUSTRATED IN THE | | FLOOR PLAN. ARE THERE ANY PROPOSED CHANGES? PLEASE | | CLARIFY. [10/11/2019 REPEAT COMMENT] | | | | 6.) THE VALUE OF THE CONSTRUCTION ($60,000) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($106,046) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. [10/11/2019 REPEAT | | COMMENT - PLEASE NOTE THAT A LANDSCAPE PERMIT MUST BE | | SUBMITTED PRIOR TO ZONING'S APPROVAL OF THIS PERMIT] | | | | | | NOTES: | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * GREEN CARD #7-191 (3 UNITS, 1 RESIDENCE + DUPLEX) | | | | * ZONE: SF7 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-10-11 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-10-11 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2019-10-11 |
Time |
|
Sent To |
|
|
Notes |
2019-10-11 12:40:47 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) UPDATED SIGNED AND SEALED SURVEY OF THE PROPERTY | | MISSING FROM THE APPLICATION. PLEASE PROVIDE. | | | | 2.) SCOPE OF WORK SPECIFIES "FULL RENOVATION," BUT IT | | DOES NOT SPECIFY WHICH BUILDING ON THE PROPERTY IS | | SUBJECT TO THE SCOPE OF WORK. | | | | 3.) PROJECT LOCATION MAP IS MISSING ON SHEET C.1 | | | | 4.) PROVIDE A SITE PLAN SHOWING ALL EXISTING AND | | PROPOSED (I.E. NEW A/C UNIT) STRUCTURES ON THE | | PROPERTY. PLEASE NOTE THAT SETBACK DIMENSIONS FROM ALL | | PROPOSED NEW STRUCTURES SHALL ALSO BE PROVIDED IN THE | | SITE PLAN. | | | | 5.) DISCREPANCIES DETECTED IN THE BUILDING | | CALCULATIONS. THE PROJECT DATA ON SHEET 1.1 INDICATES | | THAT THERE IS A COVERED PATIO, BUT IT IS NOT | | ILLUSTRATED IN THE FLOOR PLAN. ARE THERE ANY PROPOSED | | CHANGES? PLEASE CLARIFY. | | | | 6.) THE VALUE OF THE CONSTRUCTION ($60,000) EXCEEDS 50% | | OF THE STRUCTURE'S VALUE ($106,046) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | | | NOTES: | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * GREEN CARD #7-191 (3 UNITS, 1 RESIDENCE + DUPLEX) | | | | * ZONE: SF7 | | |
|
|