Plan Review Details - Permit 19100244
Plan Review Stops For Permit 19100244
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-11-07 Cont ID  
Sent By jbrooks Date 2019-11-07 Time 07:32 Rev Time 0.00
Received By jbrooks Date 2019-11-07 Time 07:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-11-05 Cont ID  
Sent By jbrooks Date 2019-11-05 Time 08:53 Rev Time 0.00
Received By jbrooks Date 2019-11-05 Time 08:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-10-10 Cont ID  
Sent By jbrooks Date 2019-10-10 Time 12:41 Rev Time 0.00
Received By jbrooks Date 2019-10-10 Time 12:41 Sent To HIST
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2019-11-06 Cont ID  
Sent By aborngra Date 2019-11-06 Time 13:53 Rev Time 0.00
Received By aborngra Date 2019-11-06 Time 13:52 Sent To PC
Notes
2019-11-06 13:53:16THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
  
 1. ALL SINGLE-HUNG WINDOWS WILL HAVE A 6/1 LITE PATTERN
 WITH EXTERNAL OGEE DIMENSIONAL MUNTINS. OPENINGS #1,
 17, 2, 4, 5, 11, 13, 15.
 2. OPENING #12 WILL HAVE A 6 LITE PATTERN WITH 2 HORIZ.
 WITH CENTER VERT. MUNTINS.
 3. MUNTINS WILL HAVE AN OGEE PROFILE AS REQUIRED BY
 HISTORICAL.
 4. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR
 CLEAR GLASS WITH LOW-E COATING. TINTED OR PRIVACY GLASS
 IS PROHIBITED.
 5. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE
 DIMENSIONAL MUNTINS. (EXCEPTION ? NO MUNTINS FOR SGD
 #14)
 6. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME OPENING AND THE LOCATION/INSET/DEPTH
 WITHIN THE ORIGINAL FRAME OPENING.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2019-11-04 Cont ID  
Sent By aborngra Date 2019-11-04 Time 13:34 Rev Time 0.00
Received By aborngra Date 2019-10-29 Time 15:43 Sent To B
Notes
2019-11-04 13:34:30THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. ALL SINGLE-HUNG WINDOWS WILL BE REQUIRED TO HAVE A
 6/1 LITE PATTERN WITH EXTERNAL OGEE DIMENSIONAL
 MUNTINS. PLEASE INCLUDE THIS INFORMATION ON THE PLANS.
 (#1, 17, 2, 4, 5, 11, 13, 15)
 2. WINDOW OPENING #12 SHALL HAVE A 6 LITE PATTERN (2
 HORIZONTAL MUNTINS WITH A CENTER VERTICAL MUNTIN) WITH
 EXTERNAL OGEE DIMENSIONAL MUNTINS.
 3. THE PROPOSED MUNTIN DETAIL IS FOR A RAISED EXTERNAL
 DIMENSIONAL MUNTIN. THE PROPOSED MUNTIN MUST HAVE AN
 OGEE PROFILE. AN ALTERNATIVE ALUMINUM PRODUCT MAY BE
 NECESSARY.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL,
 ADDITIONAL CONDITIONS MAY BE ADDED AFTER RESUBMITTAL.
 PLEASE CONFIRM THAT THESE CONDITIONS WILL BE COMPLIED
 WITH.
  
 A. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR
 CLEAR GLASS WITH LOW-E COATING. TINTED OR PRIVACY GLASS
 IS PROHIBITED.
 B. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE
 DIMENSIONAL MUNTINS. (EXCEPTION ? NO MUNTINS ON SGD
 #14)
 C. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME OPENING AND THE LOCATION/INSET/DEPTH
 WITHIN THE ORIGINAL FRAME OPENING.
  
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-10-11 Cont ID  
Sent By aborngra Date 2019-10-11 Time 12:19 Rev Time 0.00
Received By aborngra Date 2019-10-11 Time 12:19 Sent To PC
Notes
2019-10-11 12:19:43THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. A HORIZONTAL ROLLER IS AN INAPPROPRIATE WINDOW STYLE
 FOR THIS STRUCTURE. PLEASE REVISE TO TWO SINGLE-HUNG
 WINDOWS WITH A MULLION WITH AT LEAST TWO TO FOUR INCHES
 WIDE. (WINDOW #1 AND #17)
 2. A SINGLE-HUNG WINDOW IS INAPPROPRIATE FOR WINDOW
 OPENING #7 AND #9. REVISE TO A CASEMENT. THE CASEMENTS
 SHALL HAVE A 3 LITE PATTERN WITH TWO HORIZONTAL
 EXTERNAL OGEE DIMENSIONAL MUNTINS.
 3. CLARIFY OPENING #12. WHAT IS CM? I DO NOT SEE A
 PRODUCT APPROVAL INCLUDED FOR THIS OPENING.
 4. ALL SINGLE-HUNG WINDOWS WILL BE REQUIRED TO HAVE A
 6/1 LITE PATTERN WITH EXTERNAL OGEE DIMENSIONAL
 MUNTINS. PLEASE INCLUDE THIS INFORMATION ON THE PLANS.
 5. ALL PROPOSED FRENCH DOORS SHALL REPLICATE THE
 EXISTING LITE PATTERN WITH OGEE DIMENSIONAL MUNTINS.
 6. PROVIDE DETAILS OF GLASS. GLASS MUST BE CLEAR OR
 CLEAR GLASS WITH LOW-E. TINTED OR PRIVACY GLASS IS
 PROHIBITED.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL,
 ADDITIONAL CONDITIONS MAY BE ADDED AFTER RESUBMITTAL.
 PLEASE CONFIRM THAT THESE CONDITIONS WILL BE COMPLIED
 WITH.
  
 A. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR
 CLEAR GLASS WITH LOW-E COATING. TINTED OR PRIVACY GLASS
 IS PROHIBITED.
 B. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE
 DIMENSIONAL MUNTINS.
 C. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME OPENING AND THE LOCATION/INSET/DEPTH
 WITHIN THE ORIGINAL FRAME OPENING.
  
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-11-07 Cont ID  
Sent By jbrooks Date 2019-11-07 Time 07:32 Rev Time 0.00
Received By jbrooks Date 2019-10-28 Time 14:58 Sent To  
Notes
2019-10-29 14:58:57RESUB ROUTED TO HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-11 Cont ID  
Sent By jbrooks Date 2019-10-11 Time 12:42 Rev Time  
Received By cpuell Date 2019-10-04 Time 10:39 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved