Plan Review Details - Permit 19100232
Plan Review Stops For Permit 19100232
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-12-05 Cont ID  
Sent By rmcdouga Date 2019-12-05 Time 08:53 Rev Time 0.00
Received By rmcdouga Date 2019-12-04 Time 19:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-28 Cont ID  
Sent By rmcdouga Date 2019-10-28 Time 17:12 Rev Time 0.00
Received By rmcdouga Date 2019-10-28 Time 16:39 Sent To  
Notes
2019-10-28 16:42:22PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 REVISION IS DENIED BY BUILDING.
 THE REVISION TO PERMIT NUMBER 17110857 IS DENIED.
 PLEASE ADDRESS THE FOLLOWING COMMENTS.
  
 1) REMOVING THE LOWER TERRACE AREA FROM THE NORTH SIDE
 OF THE BUILDING WILL ELIMINATE THE NORTHEAST EMERGENCY
 EXIT UNTIL THE TERRACE HAS BEEN COMPLETED. SUBMIT A
 REVISED FIRST FLOOR LIFE SAFETY PLAN. FBC 107.2.1
  
 2) SPECIFY HOW FALL PROTECTION WILL BE PROVIDED AT THE
 LANDING AND STAIRS THAT ARE ADJACENT TO THE LOWER
 TERRACE AREA. FBC 1015
  
 3) A SEPARATE PERMIT APPLICATION, PLANS AND REVIEWS
 WILL BE REQUIRED FOR THE FIRST FLOOR TERRACE AND ENTRY
 CHANGES. FBC 105 AND 107
  
 4) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-10-23 Cont ID  
Sent By jpearson Date 2019-10-23 Time 10:19 Rev Time 0.00
Received By jpearson Date 2019-10-23 Time 10:19 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-10-09 Cont ID  
Sent By J.Walker Date 2019-10-09 Time   Rev Time 0.00
Received By jwalker Date 2019-10-09 Time   Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-05 Cont ID  
Sent By rmcdouga Date 2019-12-05 Time 09:49 Rev Time 0.00
Received By rmcdouga Date 2019-11-14 Time 09:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-12 Cont ID  
Sent By lmarchan Date 2019-11-12 Time 10:05 Rev Time 0.00
Received By lmarchan Date 2019-10-04 Time 14:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-12-05 Cont ID  
Sent By rmcdouga Date 2019-12-05 Time 09:49 Rev Time 0.00
Received By rmcdouga Date 2019-12-05 Time 09:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-10-28 Cont ID  
Sent By rmcdouga Date 2019-10-28 Time 17:12 Rev Time 0.00
Received By rmcdouga Date 2019-10-28 Time 17:12 Sent To  
Notes
2019-10-28 17:14:10ALL SIGNATURES ARE APPROVED AT THIS TIME, HOWEVER, ALL
 NEW PAGES WIIL HAVE TO BE REVIEWED.

Review Stop Z ZONING
Rev No 2 Status P Date 2019-11-27 Cont ID  
Sent By aaponte Date 2019-11-27 Time 11:00 Rev Time 0.00
Received By aaponte Date 2019-11-27 Time 10:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-11-08 Cont ID  
Sent By aaponte Date 2019-11-08 Time 16:47 Rev Time 0.00
Received By aaponte Date 2019-11-08 Time 16:47 Sent To  
Notes
2019-11-08 16:51:231. PLEASE CALL OUT THE MATERIALS OF THE NORTH FACADE
 WEST OF THE FOLDING DOOR AT GROUND LEVEL. IS THAT STILL
 WINDOWS? IDENTIFY THE AREA THAT CHANGED FROM PREVIOUS
 APPROVAL.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.