Plan Review Details - Permit 19100096
Plan Review Stops For Permit 19100096
Review Stop ENG-P ENGINEERING PLANNING REVIEW
Rev No 2 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2019-12-10 09:02:17LOCATION: HOWARD PARK SOUTH OF OKEECHOBEE BLVD
  
 DRAWING:
 1) SH C-1A NO CITY UTILITIES LOCATED.
  
 CONTACT: GORDON PATRIE / [email protected] OR
 561-494-1082

Review Stop ENG-P ENGINEERING PLANNING REVIEW
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2019-10-07 09:21:44PERMIT 19100096 1300 PARKER AVE.
  
 PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE
 DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401
 OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE
 COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION.
 THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO
 REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF
 HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS,
 THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION,
 NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE
 APPROVED.
  
 1) ENGINEERING PLANS:
  
 A. ALL DRAWINGS TO BE SHOWN OVER AERIALS SHOWING ALL
 CITY OF WEST PALM BEACH UTILITIES.
  
 B. SUBMIT COPIES OF ALL AS-BUILT AND UTILITITY LOCATE
 DRAWINGS FROM THE CITY OF WPB.
  
 C. IRRIGATION LINES NOT SHOWN.
  
 2) SURVEY OF UNDERGROUND FACILITIES:
  
 A. ALL UNDERGROUND UTILITIES NEED TO BE PROVIDED ON THE
 SURVEY. THE PROVIDED SURVEY SPECIFICALLY STATES THAT NO
 UNDERGROUND UTILITY LOCATES WERE DONE, WHICH DOES NOT
 COMPLY WITH THE CITY CODE REQUIREMENTS.
  
 B. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS
 SURVEY INFORMATION.
  
 3) SURVEY OF ABOVEGROUND FACILITIES - A NEW POLE IS
 BEING INSTALLED ABOVEGROUND SO THIS IS REQUIRED.
  
 A. PLEASE NOTE THAT THE SURVEY DOES NOT PROVIDE THE
 SIZE OF THE PROPOSED POLE BASE DIAMETER, WHICH WILL
 NEED TO BE CORRECTED ON THE REVISED SURVEY.
  
 B. IDENTIFY ALL ABOVEGROUND COMMUNICATION FACILITIES IN
 THE AREA TO INCLUDE AN INVENTORY OF THE REGISTRANT'S
 EXISTING FACILITIES - NO INFORMATION ON EXISTING
 FACILITIES WAS PROVIDED. SHOW THIS INFORMATION ON THE
 PLANS AND PROVIDE A NARRATIVE. IF THERE ARE NO
 FACILITIES, THIS SHALL BE NOTED ON THE SURVEY.
  
 4) ALL RESTORATION PER CITY OF WEST PALM BEACH
 STANDARDS.
  
 5) CONCEALMENT METHODS DESCRIPTIONS - NO CONCEALMENT
 INFORMATION WAS PROVIDED. PLEASE NOTE THAT THE PROPOSED
 SUPPORT POLE DOES NOT MEET THE CITY CONCEALMENT
 STANDARDS OUTLINED IN SECTION 78-411 OF THE CITY CODE.
 PROVIDE PLANS AND NARRATIVE ON HOW THE INSTALLATION
 COMPLIES WITH THE CITY'S CONCEALMENT REQUIREMENT.
  
 6) RESTORATION ESTIMATE - YOU MUST PROVIDE A
 RESTORATION ESTIMATE FOR THE SPECIFIC LOCATION OF THE
 POLE, NOT A GENERIC ESTIMATE THAT IS NOT LINKED TO THE
 SPECIFIC LOCATION AND WORK TO BE DONE.
  
 7) RADIO FREQUENCY INTERFERENCE - NO INFORMATION WAS
 PROVIDED THAT THE PROPOSED FACILITIES WILL NOT CAUSE
 RADIO FREQUENCY INTERFERENCE WITH THE CITY'S PUBLIC
 SAFETY COMMUNICATIONS EQUIPMENT. PROVIDE A STATEMENT
 REGARDING RADIO FREQUENCY INTERFERENCE.
  
 8) EVIDENCE OF INSURANCE COVERAGE
  
 A. THE CERTIFICATE OF LIABILITY INSURANCE LISTS ONLY
 THE CITY OF WEST PALM BEACH AS THE ADDITIONAL INSURED.
 THE CERTIFICATE OF LIABILITY INSURANCE NEEDS TO BE
 REVISED TO NAME THE CITY OF WEST PALM BEACH, ITS
 COMMISSIONERS, OFFICERS, EMPLOYEES AND AGENTS AS
 ADDITIONAL INSURED.
  
 B. THE CERTIFICATE OF LIABILITY INSURANCE STATES THAT
 THE INSTALLATION IS IN ST. LUCIE COUNTY. THE WORK IS
 ACTUALLY WITHIN WEST PALM BEACH AND THE CERTIFICATE OF
 LIABILITY INSURANCE NEEDS TO BE CHANGED TO REFLECT
 THIS.
  
 9) START OF OPERATION - AN ATTESTATION FROM THE
 COMMUNICATIONS FACILITIES SERVICE PROVIDER THAT
 COMMUNICATIONS SERVICES FACILITIES WILL BE INSTALLED
 AND OPERATIONAL ON THE PROPOSED STRUCTURE NO LATER THAN
 NINE MONTHS AFTER THE DATE THE APPLICATION IS APPROVED
 IS REQUIRED. PROVIDE THE REQUIRED ATTESTATION.
  
  
 10) ELECTRONIC FORMAT OF SUBMITTAL - THE SUBMITTAL WAS
 NOT PROVIDED IN ELECTRONIC FORM. A COPY OF ALL OF THE
 SUBMITTAL MATERIAL MUST BE SUBMITTED IN ELECTRONIC
 FORMAT.
  
 11) PROOF OF MAILING NOTICE TO OWNERS, ONE COPY OF
 ADDRESS LIST OF PROPERTY OWNER'S ADDRESSES WITHIN 250
 FEET AND ONE COPY OF RADIUS MAP PROVIDED BY THE PAPA
 SHOWING THOSE PROPERTIES WITHIN 250 FEET OF AFFECTED
 RIGHTS-OF-WAY - A COPY OF THE RADIUS MAP WAS NOT
 SUBMITTED. THE OWNER'S ADDRESS LIST, WHILE SUBMITTED IS
 SUCH A SMALL FONT THAT IT IS NOT EASILY READABLE.
 PLEASE PROVIDE THE RADIUS MAP FROM PAPA AND THE ADDRESS
 LIST AT A BIGGER, READABLE FONT.
  
 12) NO WIND LOAD CALCULATIONS WERE PROVIDED.
  
 CONTACT GORDON PATRIE @ (561) 494-1082
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2019-12-18 Cont ID  
Sent By eschneid Date 2019-12-18 Time 15:49 Rev Time 0.25
Received By eschneid Date 2019-12-18 Time 15:49 Sent To  
Notes
2019-12-18 15:49:58FAILED - DO NOT RESUBMIT UNDER THIS PERMIT NUMBER
  
 PERMIT 19100096 SPRINT SPECTRUM 1300 PARKER MI90XS878-M
  
 THE LOCATION OF THIS POLE IS NOT ON A RIGHT-OF-WAY, BUT
 RATHER PROPERTY OWNED BY THE CITY OF WEST PALM BEACH,
 SPECIFICALLY HOWARD PARK. THIS LOCATION WITHIN HOWARD
 PARK IS NOT DESIGNATED AS A COMMUNICATION FACILITY
 LOCATION ON THE PUBLIC LAND INVENTORY SITES LISTED IN
 THE CITY'S WIRELESS MASTER PLAN. THE HOWARD PARK SITE
 IS FURTHER SOUTH AT FIRE STATION NO. 4.
  
 SINCE YOU HAVE PROPOSED TO INSTALL A NON-CONCEALED
 ATTACHED ANTENNA TO AN EXISTING FPL POLE ON CITY
 PROPERTY, YOU WILL NEED TO SUBMIT A WIRELESS
 COMMUNICATION APPLICATION FOR A LEVEL II REVIEW IN
 ACCORDANCE WITH SECTION 94-325 OF THE CITY'S ZONING AND
 DEVELOPMENT REGULATIONS. THE APPLICATION IS AVAILABLE
 ON LINE AT HTTPS://WPB.ORG/GETATTACHMENT/DEPARTMENTS/DE
 VELOPMENT-SERVICES/PLANNING/FORMS/2017-WIRELESS-COMMUNI
 CATION-FACILITIES-APPLICATION-02-22-2017.PDF;?LANG=EN-U
 S
  
 PLEASE NOTE THAT AS PART OF THE APPLICATION YOU WILL
 NEED TO PROVIDE THE CONSENT FROM FPL FOR THE ATTACHMENT
 TO THEIR POLE. CONTRARY TO THE RESPONSE TO THESE
 COMMENTS THE CONSENT WAS NOT INCLUDED. ADDITIONALLY,
 THE ATTACHMENTS MUST BE CONTAINED WITHIN CANISTERS,
 WHICH IS NOT THE CASE WITH THE PROPOSED DESIGN.
  
 THE GROUND MOUNTED EQUIPMENT BOX IS ON CITY PROPERTY,
 SO IT REQUIRES AN EASEMENT LEASE WITH THE CITY OF WEST
 PALM BEACH. PLEASE CONTACT ELIZABETH HERINGTON-SMITH,
 CITYSCAPE CONSULTANTS, INC., (561) 542-3104. AS THE
 CITY'S WIRELESS CONSULTANT SHE CAN BEGIN THE DISCUSSION
 ON THE LEASE FOR THE WIRELESS GROUND EQUIPMENT. GROUND
 MOUNTED EQUIPMENT IS REQUIRED TO BE SCREENED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-10-07 Cont ID  
Sent By eschneid Date 2019-10-07 Time 15:01 Rev Time 0.50
Received By eschneid Date 2019-10-07 Time 15:01 Sent To  
Notes
2019-10-07 15:20:26FAILED
  
 PROVIDE WRITTEN RESPONSE TO COMMENTS.
  
 PERMIT 19100096 SPRINT SPECTRUM 1300 PARKER MI90XS878-M
  
 THE LOCATION OF THIS POLE IS NOT ON A RIGHT-OF-WAY, BUT
 RATHER PROPERTY OWNED BY THE CITY OF WEST PALM BEACH,
 SPECIFICALLY HOWARD PARK. THIS LOCATION WITHIN HOWARD
 PARK IS NOT DESIGNATED AS A COMMUNICATION FACILITY
 LOCATION ON THE PUBLIC LAND INVENTORY SITES LISTED IN
 THE CITY'S WIRELESS MASTER PLAN. THE HOWARD PARK SITE
 IS FURTHER SOUTH AT FIRE STATION NO. 4.
  
 IF YOU ARE INTERESTED IN PURSUING A TOWER AT THIS
 LOCATION, PLEASE CONTACT ELIZABETH HERINGTON-SMITH,
 CITYSCAPE CONSULTANTS, INC., (561) 542-3104. CITYSCAPE
 IS THE CITY'S WIRELESS CONSULTANT AND WILL BE ABLE TO
 PROVIDE INFORMATION ON THIS LOCATION, TO INCLUDE THE
 PROPER APPLICATION PROCESS.
  
 PLEASE NOTE THAT YOUR APPLICATION NOTES THAT THIS IS A
 NEW TOWER. AS SUCH, THE PROPOSED SUPPORT POLE WITH
 EXTERIOR CABLES, NON-CONCEALED ANTENNAS AND A REMOTE
 EQUIPMENT CABINET DO NOT COMPLY WITH THE CONCEALMENT
 STANDARDS OUTLINED IN SECTION 78-411 OF THE CITY CODE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]