Plan Review Stops For Permit 19091105 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-05-28 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-05-28 |
Time |
11:35 |
Sent To |
|
|
Notes |
2020-05-28 11:35:53 | NOTE: | | ENERGY CALCULATIONS SUBMITTED ON 05/18/2020 ARE NOT | | REVISED. THEY ARE THE SAME CALCULATIONS THAT WERE | | PREVIOUSLY SUBMITTED . THEY WERE PRINTED ON 03/03/2020. | | CALCULATIONS NEED TO BE REVISED. SEE PROVISO BELOW. | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-REVISE ENERGY CALCULATIONS: | | A) REVISE WINDOWS AREAS AND ORIENTATION TO MATCH PLANS. | | B) REVISE DOORS ORIENTATION TO MATCH PLANS. | | C) REVISE DOOR TYPE TO MATCH PLANS AND PRODUCT | | APPROVALS. (NO WOOD) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2020-03-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-24 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-24 |
Time |
11:59 |
Sent To |
|
|
Notes |
2020-03-24 15:09:08 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-REVISE ENERGY CALCULATIONS: | | A) REVISE WINDOWS AREAS AND ORIENTATION TO MATCH PLANS. | | B) REVISE DOORS ORIENTATION TO MATCH PLANS. | | C) REVISE DOOR TYPE TO MATCH PLANS AND PRODUCT | | APPROVALS. (NO WOOD) | | | | 2- REVISE THE DESIGN CRITERIA ON SHEET A-2. CURRENT | | CODE IS THE 2017 NOT 2007. BUILDING EXPOSURE IS "C" NOT | | "B". REVISE DESIGN PRESSURES ACCORDINGLY. | | NOTE: COORDINATE WITH DESIGN CRITERIA ON SHEET A-1 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2020-02-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-12 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-02-11 |
Time |
15:00 |
Sent To |
|
|
Notes |
2020-02-12 11:10:03 | DENIED: | | THIS BUILDING CAN NOT BE APPROVED WITH PROVISO. PLANS | | SUBMITTED ARE FOR THE 5 BEDROOM MODEL. ACCORDING TO | | CONTRACTOR A DIFFERENT MODEL NEEDS TO BE BUILT IN THIS | | LOT BECAUSE THE 5 BEDROOM MODEL DOESN'T MEET THE ZONING | | SETBACKS. CONTRACTOR ONLY SUBMITTED THE REVISED SURVEY | | SHOWING THE NEW PROPOSED MODEL. NEED TO SUBMIT COMPLETE | | FLOOR PLANS AND ENERGY CALCULATIONS FOR THE PROPOSED | | MODEL FOR COMPLETE REVIEW. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-19 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-19 |
Time |
09:32 |
Sent To |
|
|
Notes |
2019-12-19 09:33:43 | 12/18/19 MET WITH CHRISTOPHER BACHE (CONTRACTOR). HE | | AGREED TO PASS BUILDING REVIEWS WITH PROVISO. JG. | | | | 12/19/19 DENIED: | | THIS BUILDING CAN NOT BE APPROVED WITH PROVISO. PLANS | | SUBMITTED ARE FOR THE 5 BEDROOM MODEL. ACCORDING TO | | CONTRACTOR A DIFFERENT MODEL NEEDS TO BE BUILT IN THIS | | LOT BECAUSE THE 5 BEDROOM MODEL DOESN'T MEET THE ZONING | | SETBACKS. CONTRACTOR ONLY SUBMITTED THE REVISED SURVEY | | SHOWING THE NEW PROPOSED MODEL. NEED TO SUBMIT COMPLETE | | FLOOR PLANS AND ENERGY CALCULATIONS FOR THE PROPOSED | | MODEL. | | | | | | | | ********PREVIOUS COMMENTS: | | | | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | ISSUANCE. | | | | | | 1- ENERGY CALCULATIONS: | | A)MISSING THE ENERGY CALCULATIONS. PROVIDE ENERGY | | CALCULATIONS (2 COPIES) AS REQUIRED BY SEC. R101.5.1 | | FBC-ENERGY CONSERVATION. | | | | RESPONSE: | | REVISE ENERGY CALCULATIONS SUBMITTED: | | A) NUMBER OF BEDROOMS IS INCORRECT. REVISE ITEM #4 ON | | PAGE 1 OF 4. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | B) CONDITIONED FLOOR AREA ON ITEM #6 ON PAGE 1 OF 4 | | DOESN'T MATCH PLANS. REVISE AS REQUIRED. SEC. | | R101.5.1.1.2 FBC-RESIDENTIAL. | | | | C) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING THE BUILDER'S NAME, PERMIT OFFICE AND | | JURISDICTION SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | D) DOORS INFORMATION ON PAGE 3 OF 4 IS INCORRECT. THERE | | ARE NO DOORS N THE WEST SIDE AND THERE ARE NO WOOD | | DOORS SHOWN ON PLANS OR PRODUCT APPROVALS SUBMITTED. | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | E) WINDOWS INFORMATION ON PAGE 3 OF 4 DOESN'T MATCH | | PLANS. REVISE THE WINDOWS ORIENTATION AND AREA TO MATCH | | PLANS. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | 2- SURVEY SUBMITTED: | | HOUSE FOOTPRINT SHOWN ON THE NEW SURVEY SUBMITTED | | DOESN'T MATCH HOUSE FOOTPRINT OF PLANS SUBMITTED. PLANS | | ARE FOR A 5 BEDROOM HOUSE. NEED TO COORDINATE PLANS AND | | SURVEY. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 3- OK | | | | 4- OK | | | | 5- OK | | | | 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A)ENTRY DOOR AS SHOWN ON PLANS. | | | | RESPONSE: | | ONLY ONE PRODUCT APPROVAL WAS SUBMITTED. NEED TWO. SEC. | | 107.1 CITY AMENDMENTS. | | | | 7-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | 8- OK | | | | 9- OK | | | | 10-IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE | | DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-11 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-11 |
Time |
08:11 |
Sent To |
|
|
Notes |
2019-12-11 08:28:28 | | | 12/19/19 DENIED: | | PLANS SUBMITTED ARE FOR THE 5 BEDROOM MODEL. ACCORDING | | TO CONTRACTOR A DIFFERENT MODEL NEEDS TO BE BUILT IN | | THIS LOT BECAUSE THE 5 BEDROOM MODEL DOESN'T MEET THE | | ZONING SETBACKS. CONTRACTOR ONLY SUBMITTED THE REVISED | | SURVEY SHOWING THE NEW PROPOSED MODEL. NEED TO SUBMIT | | COMPLETE FLOOR PLANS AND ENERGY CALCULATIONS FOR THE | | PROPOSED MODEL. | | | | | | | | ***COMMENTS BELOW APPLY ONLY TO THE 5 BEDROOM MODEL | | THAT WAS ORIGINALLY SUBMITTED: | | | | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | ISSUANCE. | | | | | | 1- ENERGY CALCULATIONS: | | A)MISSING THE ENERGY CALCULATIONS. PROVIDE ENERGY | | CALCULATIONS (2 COPIES) AS REQUIRED BY SEC. R101.5.1 | | FBC-ENERGY CONSERVATION. | | | | RESPONSE: | | REVISE ENERGY CALCULATIONS SUBMITTED: | | A) NUMBER OF BEDROOMS IS INCORRECT. REVISE ITEM #4 ON | | PAGE 1 OF 4. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | B) CONDITIONED FLOOR AREA ON ITEM #6 ON PAGE 1 OF 4 | | DOESN'T MATCH PLANS. REVISE AS REQUIRED. SEC. | | R101.5.1.1.2 FBC-RESIDENTIAL. | | | | C) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING THE BUILDER'S NAME, PERMIT OFFICE AND | | JURISDICTION SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | D) DOORS INFORMATION ON PAGE 3 OF 4 IS INCORRECT. THERE | | ARE NO DOORS N THE WEST SIDE AND THERE ARE NO WOOD | | DOORS SHOWN ON PLANS OR PRODUCT APPROVALS SUBMITTED. | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | E) WINDOWS INFORMATION ON PAGE 3 OF 4 DOESN'T MATCH | | PLANS. REVISE THE WINDOWS ORIENTATION AND AREA TO MATCH | | PLANS. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | 2- SURVEY SUBMITTED: | | HOUSE FOOTPRINT SHOWN ON THE NEW SURVEY SUBMITTED | | DOESN'T MATCH HOUSE FOOTPRINT OF PLANS SUBMITTED. PLANS | | ARE FOR A 5 BEDROOM HOUSE. NEED TO COORDINATE PLANS AND | | SURVEY. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 3- OK | | | | 4- OK | | | | 5- OK | | | | 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A)ENTRY DOOR AS SHOWN ON PLANS. | | | | RESPONSE: | | ONLY ONE PRODUCT APPROVAL WAS SUBMITTED. NEED TWO. SEC. | | 107.1 CITY AMENDMENTS. | | | | 7-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | 8- OK | | | | 9- OK | | | | 10-IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE | | DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-17 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-17 |
Time |
15:15 |
Sent To |
|
|
Notes |
2019-10-17 15:20:42 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- ENERGY CALCULATIONS: | | A)MISSING THE ENERGY CALCULATIONS. PROVIDE ENERGY | | CALCULATIONS (2 COPIES) AS REQUIRED BY SEC. R101.5.1 | | FBC-ENERGY CONSERVATION. | | | | B) AN ENVELOPE LEAKAGE TEST REPORT PERFORMANCE METHOD | | WAS SUBMITTED WITH THE CONTRACTOR CERTIFYING THAT THE | | ENVELOPE LEAKAGE PERFORMANCE RESULTS DEMONSTRATE | | COMPLIANCE. CONTRACTOR TO CLAREIFY HOW CAN THE | | CONTRACTOR CERTIFY THAT THE ENVELOPE LEAKAGE | | PERFORMANCE RESULTS IS IN COMPLIANCE IF THE HOSE IS NOT | | BUILT YET? | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 2- SURVEY SUBMITTED: | | A) SURVEY SUBMITTED IS NOT DRAWN TO SCALE. SURVEY | | SPECIFIES 1"-10' SCALE. NEED A LARGER SHEET SIZE AS | | NOTED ON SURVEY REPORT NOTE #13 OR PROVIDE SURVEY WITH | | TRUE SCALE. SEC. | | 107.2.1.3 CITY AMENDMENTS. | | | | B) SURVEY SUBMITTED HAS A PRINTED COPY OF A DIGITAL | | SIGNATURE. DIGITAL SIGNATURES ARE FOR ELECTRONICALLY | | SUBMITTED DOCUMENTS. THIS IS NOT AN ELECTRONIC | | SUBMITTAL. SURVEY NEEDS ORIGINAL SEAL AND SIGNATURE AS | | REQUIRED BY SEC. 472.025 FLORIDA STATUES. | | | | 3- ATTIC ACCESS SIZE SPECIFIED ON PLANS (22"X54")DON'T | | SEEM TO FIT ON THE HALLWAY THE WAY IS SHOWN ON PLANS. | | IF THIS IS THE SIZE THAT IS GOING TO BE INSTALLED, THEN | | THE OPENING NEEDS TO BE ORIENTED PERPENDICULAR TO THE | | ROOF TRUSSES AND STRUCTURAL FRAMING DETAILS WILL NEED | | TO BE PROVIDED. REVISE AS REQUIRED. SEC. R301.1 | | FBC-RESIDENTIAL. SEC. 107.2.1 CITY AMENDMENTS. | | | | 4- REVISE DOOR/WINDOW BUCK NOTES ON SHEET A-1. BEVELED | | BUCKS AR NOT ALLOWED. THE BUCK NEEDS TO EXTEND BEYOND | | THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME AS | | REQUIRED BY SEC. R609.7.2.1 FBC-RESIDENTIAL. REVISE | | NOTES AS REQUIRED. | | | | 5- ROOF SHEATHING NAILING TYPE AND SIZE SPECIFIED ON | | THE TYPICAL WALL SECTION ON SHEET S-3 DOESN'T MATCH THE | | SPECIFICATIONS SHOWN ON THE ROOF SHEATHING DIAPHRAGM | | SCHEDULE ON SHEET S-2. REVISE AS REQUIRED TO MATCH. | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A)ENTRY DOOR AS SHOWN ON PLANS. | | | | B) ROOF SHINGLES. PROVIDE FLORIDA PRODUCT APPROVAL | | COVER PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. NEED | | COVER PAGE TO VERIFY CURRENT CODE AND IF THE PRODUCT IS | | APPROVED. | | | | C) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | 7-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | 8- TRUSS PACKAGE | | NOTE: | | TRUSS PACKAGE IS NOT REQUIRED TO BE SUBMITTED FOR PLAN | | REVIEW FOR ONE AND TWO FAMILY BUILDINGS. CONTRACTOR MAY | | DELIVER THE TRUSS PACKAGE TO THE BUILDING INSPECTOR AT | | THE TIME OF FRAMING INSPECTIONS AFTER CORRECTIONS | | ADDRESSING THE COMMENTS ARE ADDRESSED. | | | | A) ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | TRUSS DRAWING AND TRUSS LAYOUT AS REQUIRED BY SEC. | | 107.3.4.1 CITY AMENDMENTS. | | | | B)TRUSS PACKAGE SUBMITTED NEEDS A TITLE BLOCK WITH THE | | INFORMATION OF THE TRUSS ENGINEER ON EACH SHEET AND | | EACH SHEET NEEDS TO BE SIGNED AND SEALED BY THE TRUSS | | ENGINEER AS REQUIRED BY SEC. 61G15-23.001 FAC. | | | | C) TRUSS LAYOUT TO SHOW THE TRUSS TO TRUSS CONNECTORS | | AND LOCATION. TRUSS ENGINEER TO SIGN AND SEAL THESE | | PLANS AND PROVIDE HIS INFORMATION AS REQUIRED BY FAC | | 61G15-23.001. OR PROVIDE COMPLETE STRUCTURAL | | CONNECTIONS ON EACH INDIVIDUAL TRUSS DRAWING. | | | | 9- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW BASED ON ALL THE SCOPE OF WORK. VALUATION TO | | INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND | | PROFIT AND DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC. | | 109.3 CITY AMENDMENTS. VALUATION WAS UPDATED TO | | $201,054. THE PERMIT FEE BALANCE IS $4503.23. | | | | 10-IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE | | DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2020-05-29 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-05-29 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-05-29 |
Time |
09:07 |
Sent To |
|
|
Notes |
2020-05-28 11:35:41 | NEW SET OF PLANS SUBMITTED. JG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2020-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-03-25 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-03-25 |
Time |
12:18 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-12-19 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-12-19 |
Time |
10:32 |
Sent To |
|
|
Notes |
2019-12-19 10:32:18 | MODEL NEEDS TO BE CHANGED PER ZONING SETBACKS, SO NEW | | PLAN WILL NEED TO BE SUBMITTED AND REVIEWED FOR THAT | | MODEL. WPB FBC 105.1, 107.2.1 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-12-13 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-12-13 |
Time |
11:48 |
Sent To |
|
|
Notes |
2019-12-19 10:32:41 | SEE 3RD REVIEW NOTE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-10-16 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-10-16 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-10-16 |
Time |
10:16 |
Sent To |
|
|
Notes |
2019-10-16 11:19:01 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. RISER DIAGRAM IS NOT CODE COMPLIANT. THE SERVICE | | CONDUCTORS MUST HAVE OVERCURRENT PROTECTION WHERE THEY | | ENTER THE DWELLING UNIT. SERVICE CONDUCTORS ARE NOT | | PERMITTED TO EXTEND FURTHER THAN 8 FEET INTO A | | STRUCTURE WITHOUT OVERCURRENT PROTECTION. IF THIS | | OVERCURRENT PROTECTION IS LOCATED ON THE EXTERIOR OF | | THE DWELLING, THAN THE CONDUIT TO THE INTERIOR PANEL | | MUST INCLUDE AN EQUIPMENT GROUNDING CONDUCTOR. IF THE | | CONDUCTORS ARE RUN UNDERGROUND FROM THE METER TO THE | | INTERIOR PANEL, AND THAT PANEL HAS A MAIN BREAKER, THE | | CONDUCTORS MUST NOT EXCEED 8 FEET IN LENGTH BEFORE | | TERMINATION TO THE MAIN BREAKER. PROVIDE CLARIFICATION | | AND/OR CORRECTION. NEC 230.70, 250.122; FBC RE E3601.6, | | E3704.6, 3607.3.1 | | 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | 3. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS | | SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8(A)(9); FBC RE E3902.9 | | 4. NOTE 12 STATES THAT LIGHTING IN CLOTHES CLOSETS | | SHALL COMPLY WITH NEC 410.8, WHICH IS NOT THE CORRECT | | CODE. PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 | | 5. NOTE 18 STATES THAT RECEPTACLES SHALL BE TAMPER | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2020-05-29 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-05-29 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-05-18 |
Time |
13:47 |
Sent To |
|
|
Notes |
2020-05-21 17:02:21 | ROUTED TO JULIO GOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2020-04-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-04-06 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-04-02 |
Time |
08:45 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2020-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-03-25 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-03-05 |
Time |
13:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-02-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-12 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-01-17 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-12-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-12-23 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-12-19 |
Time |
09:31 |
Sent To |
|
|
Notes |
2019-12-19 09:31:48 | 12/18/19 MET WITH CHRISTOPHER BACHE (CONTRACTOR). HE | | AGREED TO PASS REVIEWS WITH PROVISO. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-12-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-12-13 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-12-03 |
Time |
15:04 |
Sent To |
|
|
Notes |
2019-12-13 09:55:20 | TO CT DESK | | | 2019-12-04 15:04:22 | R26 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-10-21 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-09-26 |
Time |
14:38 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
6 |
Status |
P |
Date |
2020-04-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-04-06 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-04-06 |
Time |
08:26 |
Sent To |
|
|
Notes |
2020-04-06 08:43:04 | $2,695.44 PAID. MU-2020-000972. | | | | COUNTY STAMPED PLANS ON 03/27/2020 CONFIRMING THAT FEES | | PAID ARE FOR THIS LOT. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
5 |
Status |
F |
Date |
2020-03-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-24 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-24 |
Time |
15:19 |
Sent To |
|
|
Notes |
2020-03-24 15:23:35 | IMPACT FEES MU-2020-000972 ARE FOR THE 5 BEDROOM MODEL. | | THIS MODEL IS NOT GOING TO BE BUILT IN THIS LOT BECAUSE | | IT DOESN'T MEET THE ZONING REQUIREMENTS. THE NEW | | PROPOSED MODEL NEEDS TO BE REVIEWED BY THE COUNTY FOR | | IMPACT FEES. | | THE IMPACT FEES NEED TO BE COORDINATED WITH NEW MODEL. | | PROVIDE COUNTY STAMPED PLANS WITH THE NEW MODEL. | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
F |
Date |
2020-02-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-12 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-02-12 |
Time |
11:25 |
Sent To |
|
|
Notes |
2020-02-12 11:28:52 | IMPACT FEES MU-2020-000972 ARE FOR THE 5 BEDROOM MODEL. | | THIS MODEL IS NOT GOING TO BE BUILT IN THIS LOT BECAUSE | | IT DOESN'T MEET THE ZONING REQUIREMENTS. A NEW SET OF | | PLANS FOR PROPOSED MODEL NEEDS TO BE SUBMITTED FOR | | COMPLETE REVIEW. THE IMPACT FEES NEED TO BE COORDINATED | | WITH NEW MODEL. | | | | | | | | DENIED: | | THIS BUILDING CAN NOT BE APPROVED WITH PROVISO. PLANS | | SUBMITTED ARE FOR THE 5 BEDROOM MODEL. ACCORDING TO | | CONTRACTOR A DIFFERENT MODEL NEEDS TO BE BUILT IN THIS | | LOT BECAUSE THE 5 BEDROOM MODEL DOESN'T MEET THE ZONING | | SETBACKS. CONTRACTOR ONLY SUBMITTED THE REVISED SURVEY | | SHOWING THE NEW PROPOSED MODEL. NEED TO SUBMIT COMPLETE | | FLOOR PLANS AND ENERGY CALCULATIONS FOR THE PROPOSED | | MODEL FOR COMPLETE REVIEW. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-19 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-19 |
Time |
10:00 |
Sent To |
|
|
Notes |
2019-12-19 10:01:04 | IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2019-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-11 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-11 |
Time |
09:16 |
Sent To |
|
|
Notes |
2019-12-11 09:16:32 | IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-17 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-17 |
Time |
15:23 |
Sent To |
|
|
Notes |
2019-10-17 15:23:52 | IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-05-28 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-05-28 |
Time |
15:49 |
Sent To |
E |
|
Notes |
2020-05-28 15:57:33 | MECHANICAL REVIEW APPROVED WITH PROVISO: | | 1- BALANCED RETURN AIR DUCT TO BE 12" MIN. AS REQUIRED | | BY SEC. M1602.3 FBC-RESIDENTIAL EXCEPTION #3. | | 2- REVISE LOAD CALCULATIONS. ENTRY DOOR DOESN'T FACE | | WEST. SEE PLANS AND REVISE AS REQUIRED. | 2020-05-28 11:35:28 | NEW SET OF PLANS SUBMITTED. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2020-04-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-04-06 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-04-06 |
Time |
08:53 |
Sent To |
|
|
Notes |
2020-04-06 09:09:50 | MECHANICAL REVIEW APPROVED WITH PROVISO PER SAMANTHA | | HILL (04/06/2020) : | | 1- PROVIDE COPY OF PLAN SHOWING THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | SEC. 17.2.1 CITY AMENDMENTS |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2020-03-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-24 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-24 |
Time |
09:30 |
Sent To |
|
|
Notes |
2020-03-24 09:51:35 | 3RD REVIEW FBC-2017 MECHANICAL | | PERMIT #19091105 | | 3/24/20 | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | COMMENT #1 FROM THE 1ST REVIEW PRINTED BELOW STILL | | EXISTS- PLEASE COMPLY. | | | | 1) THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON THE MECHANICAL PLAN SHEET | | AC-1- SECTION 107.2.1 WPB. IF THE DESIGNER IS A FL. | | LICENSED ARCHITECT OR ENGINEER, HE/SHE SHALL ALSO | | PROVIDE AN ORIGINAL SEAL AND WET SIGNATURE PER FL. | | STATUE AND SECTIONS 61G15-16.003 AND 23.002 FAC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2019-12-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-12-23 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-12-23 |
Time |
11:02 |
Sent To |
|
|
Notes |
2019-12-23 11:55:39 | PLAN REVIEW - MECHANICAL | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 3RD REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1) THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON THE MECHANICAL PLAN SHEET | | AC-1- SECTION 107.2.1 WPB. IF THE DESIGNER IS A FL. | | LICENSED ARCHITECT OR ENGINEER, HE/SHE SHALL ALSO | | PROVIDE AN ORIGINAL SEAL AND WET SIGNATURE PER FL. | | STATUE AND SECTIONS 61G15-16.003 AND 23.002 FAC. | | (NOT ADDRESSED) | | | | 2) THE ENERGYGAUGE FORM R405 LISTS NUMBER OF BEDROOMS | | AS 4. THIS MODEL HAS 5 BEDROOMS. | | ENERGY PERFORMANCE LEVEL EPL DISPLAY CARD LISTS NUMBER | | OF BEDROOMS AS 4. THIS MODEL HAS 5 BEDROOMS. | | RE-SUBMIT CORRECTED FORM R405 AND EPL CARD. | | | | 3) CORRECTED | | | | 4) CORRECTED. | | | | 5) AC-1: THE RETURN TRANSFER DUCTS FROM BEDROOMS 3, 4, | | & 5 ARE UNDERSIZED PER SECTION M1602.3 FBC RES- THE | | RETURN DUCT DIAMETERS SHALL BE 1.5 TIMES THE DIAMETERS | | OF THE SUPPLY DUCTS. (NOT ADDRESSED) | | | | 6) AC-1 EXHAUST VENTILATION AT A RATE OF 100 CFMS | | INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED | | FOR THE KITCHEN- TABLE M1507.4 FBC RES. PLEASE SEE | | SECTION M1503.1 FOR RANGE HOOD REQUIREMENTS, AND | | M1503.4 FOR MAKEUP AIR. (NOT ADDRESSED) | | | | 7) CORRECTED - AIR HANDLER RE-LOCATED TO CLOSET. | | | | 8) CORRECTED. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2019-12-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-12-13 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-12-13 |
Time |
11:48 |
Sent To |
|
|
Notes |
2019-12-13 14:08:55 | PLAN REVIEW - MECHANICAL | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1) THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON THE MECHANICAL PLAN SHEET | | AC-1- SECTION 107.2.1 WPB. IF THE DESIGNER IS A FL. | | LICENSED ARCHITECT OR ENGINEER, HE/SHE SHALL ALSO | | PROVIDE AN ORIGINAL SEAL AND WET SIGNATURE PER FL. | | STATUE AND SECTIONS 61G15-16.003 AND 23.002 FAC. | | (NOT ADDRESSED) | | | | 2) CORRECTED | | | | 3) CORRECTED | | | | 4) AC-1: INDICATE THE SIZE OF THE DUCT FROM THE RAG TO | | THE AIR HANDLER- SECTION M1602.2 FBC RES. (PARTIAL | | CORRECTION) | | | | 5) AC-1: THE RETURN TRANSFER DUCTS FROM BEDROOMS 3, 4, | | & 5 ARE UNDERSIZED PER SECTION M1602.3 FBC RES- THE | | RETURN DUCT DIAMETERS SHALL BE 1.5 TIMES THE DIAMETERS | | OF THE SUPPLY DUCTS. (NOT ADDRESSED) | | | | 6) AC-1 EXHAUST VENTILATION AT A RATE OF 100 CFMS | | INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED | | FOR THE KITCHEN- TABLE M1507.4 FBC RES. PLEASE SEE | | SECTION M1503.1 FOR RANGE HOOD REQUIREMENTS, AND | | M1503.4 FOR MAKEUP AIR. (NOT ADDRESSED) | | | | 7) AC-1 VERIFY COMPLIANCE WITH SECTION R403.3.6 | | AIR-HANDLING UNITS IN ATTICS: (NOT ADDRESSED) | | | | AIR-HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC | | WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION | | R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR | | COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING | | CONDITIONS ARE MET: | | | | 1.THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | | 2.A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT DOWN | | THE UNIT WHEN THE CONDENSATION DRAIN IS NOT WORKING | | PROPERLY. | | | | 3.THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | REPLACE THE AIR HANDLER. | | | | 4.A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | CAPITALS, IN 16-POINT TYPE, WITH THE TITLE AND FIRST | | PARAGRAPH IN BOLD: | | | | | | 8) AC-1: PROVIDE ENGINEERING FOR INSTALLATION OF THE | | CONDENSER PAD AND MOUNTING OF THE CONDENSER- SECTIONS | | M1305.1.4.1 AND M1401.4 FBC RES. (DETAIL PROVIDED - | | PLAN PAGE MISSING SIGNATURE AND SEAL OF DESIGN | | PROFESSIONAL) | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-10-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-10-21 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-10-21 |
Time |
11:37 |
Sent To |
I |
|
Notes |
2019-10-21 11:43:04 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #19091105 | | 10/21/19 | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON THE MECHANICAL PLAN SHEET | | AC-1- SECTION 107.2.1 WPB. IF THE DESIGNER IS A FL. | | LICENSED ARCHITECT OR ENGINEER, HE/SHE SHALL ALSO | | PROVIDE AN ORIGINAL SEAL AND WET SIGNATURE PER FL. | | STATUE AND SECTIONS 61G15-16.003 AND 23.002 FAC. | | | | 2) THE ENERGYGAUGE FORM R405 IS MISSING FROM THE ENERGY | | COMPLIANCE SUBMITTAL- SECTION R405.2 FBC EC. | | | | 3) PROVIDE THE MANUAL J WORKSHEETS WITH THE AC SYSTEM | | SIZING CALCULATIONS- SECTION R403.7.1 FBC EC. | | | | 4) AC-1: INDICATE THE SIZE OF THE RETURN DUCT FROM THE | | MASTER BEDROOM TO THE 20X18 RAG, AND THE SIZE OF THE | | DUCT FROM THE RAG TO THE AIR HANDLER- SECTION M1602.2 | | FBC RES. | | | | 5) AC-1: THE RETURN TRANSFER DUCTS FROM BEDROOMS 3, 4, | | & 5 ARE UNDERSIZED PER SECTION M1602.3 FBC RES- THE | | RETURN DUCT DIAMETERS SHALL BE 1.5 TIMES THE DIAMETERS | | OF THE SUPPLY DUCTS. | | | | 6) AC-1 EXHAUST VENTILATION AT A RATE OF 100 CFMS | | INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED | | FOR THE KITCHEN- TABLE M1507.4 FBC RES. PLEASE SEE | | SECTION M1503.1 FOR RANGE HOOD REQUIREMENTS, AND | | M1503.4 FOR MAKEUP AIR. | | | | 7) AC-1 VERIFY COMPLIANCE WITH SECTION R403.3.6 | | AIR-HANDLING UNITS IN ATTICS: | | | | AIR-HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC | | WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION | | R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR | | COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING | | CONDITIONS ARE MET: | | | | 1.THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | | 2.A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT DOWN | | THE UNIT WHEN THE CONDENSATION DRAIN IS NOT WORKING | | PROPERLY. | | | | 3.THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | REPLACE THE AIR HANDLER. | | | | 4.A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | CAPITALS, IN 16-POINT TYPE, WITH THE TITLE AND FIRST | | PARAGRAPH IN BOLD: | | | | NOTICE TO HOMEOWNER | | A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR | | HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT | | AND ECONOMIC OPERATION OF THE AIRCONDITIONING SYSTEM, | | YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED. | | YOUR AIR-CONDITIONING SYSTEM IS EQUIPPED WITH ONE OR | | BOTH OF THE FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU | | WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR | | (2) A DEVICE THAT WILL SHUT DOWN THE SYSTEM WHEN THE | | CONDENSATION DRAIN IS NOT WORKING. TO LIMIT POTENTIAL | | DAMAGE TO YOUR HOME, AND TO AVOID DISRUPTION OF | | SERVICE, IT IS RECOMMENDED THAT YOU ENSURE PROPER | | WORKING ORDER OF THESE DEVICES BEFORE EACH SEASON OF | | PEAK OPERATION. | | | | 8) AC-1: PROVIDE ENGINEERING FOR INSTALLATION OF THE | | CONDENSER PAD AND MOUNTING OF THE CONDENSER- SECTIONS | | M1305.1.4.1 AND M1401.4 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-05-28 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-05-28 |
Time |
15:28 |
Sent To |
|
|
Notes |
2020-05-28 15:29:46 | PLUMBING APPROVED WITH PROVISO: | | 1- NO MORE THAN ONE WET-VENTED FIXTURE DRAIN SHALL | | DISCHARGE UPSTREAM OF THE DRY-VENTED FIXTURE DRAIN | | CONNECTION. | | REVISE. | | SEC. P3108.2.1 FBC-RESIDENTIAL. | 2020-05-28 11:35:15 | NEW SET OF PLANS SUBMITTED. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2020-03-19 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
jbaker |
Date |
2020-03-19 |
Time |
13:21 |
Sent To |
|
|
Notes |
2020-03-25 13:48:59 | RISER DIAGRAM HAS 3 BATHROOM GROUPS AND PLANS SHOW ONLY | | 2 BATHROOMS. | 2020-03-19 13:23:44 | PERMIT 19091105 | | 1. SHOW LAVATORY ON SANITARY RISER DIAGRAM THAT IS | | LOCATED IN BATHROOM THAT HAS A TUB. THERE ARE TWO | | LAVATORIES AND ONLY ONE IS SHOWN. 2017 FBC 107.2.1 AND | | P3005.4 IN 2017 FRC. | | 2. SHOW RELIEF VALVE PIPING FOR HOT WATER HEATER ON | | PLANS TO ITS TERMINATION POINT. 2017 FPC 504.6 | | 3. PROVIDE A HOT WATER HEATER DRAIN PAN AND SHOW | | DISCHARGE PIPING TO ITS TERMINATION POINT ON THE PLANS | | PER 2017 FPC 504.7 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2020-02-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-12 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-02-12 |
Time |
11:22 |
Sent To |
|
|
Notes |
2020-02-12 11:23:17 | | | | | DENIED: | | THIS BUILDING CAN NOT BE APPROVED WITH PROVISO. PLANS | | SUBMITTED ARE FOR THE 5 BEDROOM MODEL. ACCORDING TO | | CONTRACTOR A DIFFERENT MODEL NEEDS TO BE BUILT IN THIS | | LOT BECAUSE THE 5 BEDROOM MODEL DOESN'T MEET THE ZONING | | SETBACKS. CONTRACTOR ONLY SUBMITTED THE REVISED SURVEY | | SHOWING THE NEW PROPOSED MODEL. NEED TO SUBMIT COMPLETE | | FLOOR PLANS AND ENERGY CALCULATIONS FOR THE PROPOSED | | MODEL FOR COMPLETE REVIEW. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-19 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-19 |
Time |
09:32 |
Sent To |
|
|
Notes |
2019-12-19 09:59:39 | 12/18/19 MET WITH CHRISTOPHER BACHE (CONTRACTOR). HE | | AGREED TO PASS REVIEWS WITH PROVISO. JG. | | | | 12/19/19 DENIED: | | THIS BUILDING CAN NOT BE APPROVED WITH PROVISO. PLANS | | SUBMITTED ARE FOR THE 5 BEDROOM MODEL. ACCORDING TO | | CONTRACTOR A DIFFERENT MODEL NEEDS TO BE BUILT IN THIS | | LOT BECAUSE THE 5 BEDROOM MODEL DOESN'T MEET THE ZONING | | SETBACKS. CONTRACTOR ONLY SUBMITTED THE REVISED SURVEY | | SHOWING THE NEW PROPOSED MODEL. NEED TO SUBMIT COMPLETE | | FLOOR PLANS AND ENERGY CALCULATIONS FOR THE PROPOSED | | MODEL. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-11 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-11 |
Time |
09:22 |
Sent To |
|
|
Notes |
2019-12-19 10:00:23 | 12/19/19 DENIED: | | PLANS SUBMITTED ARE FOR THE 5 BEDROOM MODEL. ACCORDING | | TO CONTRACTOR A DIFFERENT MODEL NEEDS TO BE BUILT IN | | THIS LOT BECAUSE THE 5 BEDROOM MODEL DOESN'T MEET THE | | ZONING SETBACKS. CONTRACTOR ONLY SUBMITTED THE REVISED | | SURVEY SHOWING THE NEW PROPOSED MODEL. NEED TO SUBMIT | | COMPLETE FLOOR PLANS AND ENERGY CALCULATIONS FOR THE | | PROPOSED MODEL. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-10-04 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-10-04 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-11 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-11 |
Time |
09:16 |
Sent To |
|
|
Notes |
2019-12-11 09:17:31 | SHINGLES FL10124-R22 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-17 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-17 |
Time |
15:23 |
Sent To |
|
|
Notes |
2019-10-17 15:25:11 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A) ROOF SHINGLES. PROVIDE FLORIDA PRODUCT APPROVAL | | COVER PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. NEED | | COVER PAGE TO VERIFY CURRENT CODE AND IF THE PRODUCT IS | | APPROVED. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2020-03-16 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-03-16 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-03-16 |
Time |
16:07 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2019-12-09 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2019-12-09 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2019-12-09 |
Time |
14:12 |
Sent To |
I |
|
Notes |
2019-12-09 14:12:24 | 12/09/19 FAILED. | | | | PURUSANT ZLDR SEC. 94-72(A)(2)(B), MINIUMUM CORNER | | SETBACK FOR PRINCIPAL BUILDING IS 12.5 FEET. THE | | SETBACK PROVIDED ON THE PLANS IS 7 FEET ALONG 10TH | | STREET. PLEASE REVISE THE PLANS TO MEET THE CORNER | | SETBACK REQUIREMENTS. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT WEBSITE AT HTTPS://WPB. | | ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/OVERVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: (561) 822-1442 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-10-07 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2019-10-07 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2019-10-07 |
Time |
14:10 |
Sent To |
I |
|
Notes |
2019-10-07 14:15:32 | 10/07/19 FAILED. | | | | PURUSANT ZLDR SEC. 94-72(A)(2)(B), MINIUMUM CORNER | | SETBACK FOR PRINCIPAL BUILDING IS 12.5 FEET. THE | | SETBACK PROVIDED ON THE PLANS IS 7 FEET ALONG 10TH | | STREET. PLEASE REVISE THE PLANS TO MEET THE CORNER | | SETBACK REQUIREMENTS. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT WEBSITE AT HTTPS://WPB. | | ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/OVERVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: (561) 822-1442 | | E-MAIL: [email protected] | | |
|
|