Plan Review Stops For Permit 19091104 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2020-03-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-23 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-23 |
Time |
11:22 |
Sent To |
|
|
Notes |
2020-03-23 14:51:26 | BUILDING REVIEW APPROVED WITH PROVISO: | | (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | INSPECTIONS TO AVOID CONFLICTS/DELAYS) | | | | 1-REVISE ENERGY CALCULATIONS: | | A) REVISE # OF BEDROOMS AND CONDITIONED FLOOR AREA TO | | MATCH PLANS. | | B) PROVIDE THE BUILDER'S NAME. | | C) REVISE DOORS INFORMATION. THERE ARE NO DOORS ON THE | | WEST SIDE AND THERE ARE NO WOOD DOORS. | | D) REVISE WINDOWS ORIENTATION AND AREA TO MATCH PLANS. | | | | 2- REVISE SURVEY TO MATCH PROPOSED RESIDENCE. NO MIRROR | | IMAGE AND ALL DIMENSIONS TO MATCH PLANS. PROVIDE ACTUAL | | FOOTPRINT THAT MATCHES PLANS. | | | | 3- REVISE DRAINAGE PLAN: THE FOOTPRINT OF THE HOUSE | | DOESN'T MATCH THE PROPOSED HOUSE. NO MIRROR IMAGE. | | PROVIDE ACTUAL FOOTPRINT THAT MATCHES PLANS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2020-02-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-11 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-02-11 |
Time |
16:07 |
Sent To |
M |
|
Notes |
2020-02-11 16:10:43 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-REVISE ENERGY CALCULATIONS: | | A) REVISE # OF BEDROOMS AND CONDITIONED FLOOR AREA TO | | MATCH PLANS. | | B) PROVIDE THE BUILDER'S NAME. | | C) REVISE DOORS INFORMATION. THERE ARE NO DOORS ON THE | | WEST SIDE AND THERE ARE NO WOOD DOORS. | | D) REVISE WINDOWS ORIENTATION AND AREA TO MATCH PLANS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-02-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-19 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-19 |
Time |
15:20 |
Sent To |
|
|
Notes |
2019-12-19 15:44:47 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-REVISE ENERGY CALCULATIONS: | | A) REVISE # OF BEDROOMS AND CONDITIONED FLOOR AREA TO | | MATCH PLANS. | | B) PROVIDE THE BUILDER'S NAME. | | C) REVISE DOORS INFORMATION. THERE ARE NO DOORS ON THE | | WEST SIDE AND THERE ARE NO WOOD DOORS. | | D) REVISE WINDOWS ORIENTATION AND AREA TO MATCH PLANS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-11 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-11 |
Time |
09:46 |
Sent To |
|
|
Notes |
2019-12-11 09:50:32 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | ISSUANCE. | | | | 1- ENERGY CALCULATIONS: | | A)MISSING THE ENERGY CALCULATIONS. PROVIDE ENERGY | | CALCULATIONS (2 COPIES) AS REQUIRED BY SEC. R101.5.1 | | FBC-ENERGY CONSERVATION. | | | | RESPONSE: | | REVISE ENERGY CALCULATIONS SUBMITTED: | | A) NUMBER OF BEDROOMS IS INCORRECT. REVISE ITEM #4 ON | | PAGE 1 OF 4. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | B) CONDITIONED FLOOR AREA ON ITEM #6 ON PAGE 1 OF 4 | | DOESN'T MATCH PLANS. REVISE AS REQUIRED. SEC. | | R101.5.1.1.2 FBC-RESIDENTIAL. | | | | C) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING THE BUILDER'S NAME, PERMIT OFFICE AND | | JURISDICTION SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | D) DOORS INFORMATION ON PAGE 3 OF 4 IS INCORRECT. THERE | | ARE NO DOORS N THE WEST SIDE AND THERE ARE NO WOOD | | DOORS SHOWN ON PLANS OR PRODUCT APPROVALS SUBMITTED. | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | E) WINDOWS INFORMATION ON PAGE 3 OF 4 DOESN'T MATCH | | PLANS. REVISE THE WINDOWS ORIENTATION AND AREA TO MATCH | | PLANS. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | 2- OK | | | | 3- OK | | | | 4-OK | | | | 5- OK | | | | 6- OK | | | | 7- OK | | | | 8- OK | | | | 9-OK | | | | 10-IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE | | DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-17 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-17 |
Time |
11:36 |
Sent To |
|
|
Notes |
2019-10-17 14:17:08 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- ENERGY CALCULATIONS: | | A)MISSING THE ENERGY CALCULATIONS. PROVIDE ENERGY | | CALCULATIONS (2 COPIES) AS REQUIRED BY SEC. R101.5.1 | | FBC-ENERGY CONSERVATION. | | | | B) AN ENVELOPE LEAKAGE TEST REPORT PERFORMANCE METHOD | | WAS SUBMITTED WITH THE CONTRACTOR CERTIFYING THAT THE | | ENVELOPE LEAKAGE PERFORMANCE RESULTS DEMONSTRATE | | COMPLIANCE. CONTRACTOR TO CLAREIFY HOW CAN THE | | CONTRACTOR CERTIFY THAT THE ENVELOPE LEAKAGE | | PERFORMANCE RESULTS IS IN COMPLIANCE IF THE HOSE IS NOT | | BUILT YET? | | SEC. 107.2.1 CITY AMENDMENTS. | | | | 2- SURVEY SUBMITTED: | | A) SURVEY SUBMITTED IS NOT DRAWN TO SCALE. SURVEY | | SPECIFIES 1"-10' SCALE. NEED A LARGER SHEET SIZE AS | | NOTED ON SURVEY REPORT NOTE #13 OR PROVIDE SURVEY WITH | | TRUE SCALE. SEC. | | 107.2.1.3 CITY AMENDMENTS. | | | | B) SURVEY SUBMITTED HAS A PRINTED COPY OF A DIGITAL | | SIGNATURE. DIGITAL SIGNATURES ARE FOR ELECTRONICALLY | | SUBMITTED DOCUMENTS. THIS IS NOT AN ELECTRONIC | | SUBMITTAL. SURVEY NEEDS ORIGINAL SEAL AND SIGNATURE AS | | REQUIRED BY SEC. 472.025 FLORIDA STATUES. | | | | 3- ATTIC ACCESS SIZE SPECIFIED ON PLANS (22"X54")DON'T | | SEEM TO FIT ON THE HALLWAY THE WAY IS SHOWN ON PLANS. | | IF THIS IS THE SIZE THAT IS GOING TO BE INSTALLED, THEN | | THE OPENING NEEDS TO BE ORIENTED PERPENDICULAR TO THE | | ROOF TRUSSES AND STRUCTURAL FRAMING DETAILS WILL NEED | | TO BE PROVIDED. REVISE AS REQUIRED. SEC. R301.1 | | FBC-RESIDENTIAL. SEC. 107.2.1 CITY AMENDMENTS. | | | | 4- REVISE DOOR/WINDOW BUCK NOTES ON SHEET A-1. BEVELED | | BUCKS AR NOT ALLOWED. THE BUCK NEEDS TO EXTEND BEYOND | | THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME AS | | REQUIRED BY SEC. R609.7.2.1 FBC-RESIDENTIAL. REVISE | | NOTES AS REQUIRED. | | | | 5- ROOF SHEATHING NAILING TYPE AND SIZE SPECIFIED ON | | THE TYPICAL WALL SECTION ON SHEET S-3 DOESN'T MATCH THE | | SPECIFICATIONS SHOWN ON THE ROOF SHEATHING DIAPHRAGM | | SCHEDULE ON SHEET S-2. REVISE AS REQUIRED TO MATCH. | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A)ENTRY DOOR AS SHOWN ON PLANS. | | | | B) ROOF SHINGLES. PROVIDE FLORIDA PRODUCT APPROVAL | | COVER PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. NEED | | COVER PAGE TO VERIFY CURRENT CODE AND IF THE PRODUCT IS | | APPROVED. | | | | C) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | 7-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | 8- TRUSS PACKAGE | | NOTE: | | TRUSS PACKAGE IS NOT REQUIRED TO BE SUBMITTED FOR PLAN | | REVIEW FOR ONE AND TWO FAMILY BUILDINGS. CONTRACTOR MAY | | DELIVER THE TRUSS PACKAGE TO THE BUILDING INSPECTOR AT | | THE TIME OF FRAMING INSPECTIONS AFTER CORRECTIONS | | ADDRESSING THE COMMENTS ARE ADDRESSED. | | | | A) ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | TRUSS DRAWING AND TRUSS LAYOUT AS REQUIRED BY SEC. | | 107.3.4.1 CITY AMENDMENTS. | | | | B)TRUSS PACKAGE SUBMITTED NEEDS A TITLE BLOCK WITH THE | | INFORMATION OF THE TRUSS ENGINEER ON EACH SHEET AND | | EACH SHEET NEEDS TO BE SIGNED AND SEALED BY THE TRUSS | | ENGINEER AS REQUIRED BY SEC. 61G15-23.001 FAC. | | | | C) TRUSS LAYOUT TO SHOW THE TRUSS TO TRUSS CONNECTORS | | AND LOCATION. TRUSS ENGINEER TO SIGN AND SEAL THESE | | PLANS AND PROVIDE HIS INFORMATION AS REQUIRED BY FAC | | 61G15-23.001. OR PROVIDE COMPLETE STRUCTURAL | | CONNECTIONS ON EACH INDIVIDUAL TRUSS DRAWING. | | | | 9- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW BASED ON ALL THE SCOPE OF WORK. VALUATION TO | | INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND | | PROFIT AND DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC. | | 109.3 CITY AMENDMENTS. VALUATION WAS UPDATED TO | | $201,054. THE PERMIT FEE BALANCE IS $4503.23. | | | | 10-IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE | | DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-03-25 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-03-25 |
Time |
12:11 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-12-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-12-20 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-12-20 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-10-16 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-10-16 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-10-16 |
Time |
10:15 |
Sent To |
|
|
Notes |
2019-10-16 10:56:10 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. RISER DIAGRAM IS NOT CODE COMPLIANT. THE SERVICE | | CONDUCTORS MUST HAVE OVERCURRENT PROTECTION WHERE THEY | | ENTER THE DWELLING UNIT. SERVICE CONDUCTORS ARE NOT | | PERMITTED TO EXTEND FURTHER THAN 8 FEET INTO A | | STRUCTURE WITHOUT OVERCURRENT PROTECTION. IF THIS | | OVERCURRENT PROTECTION IS LOCATED ON THE EXTERIOR OF | | THE DWELLING, THAN THE CONDUIT TO THE INTERIOR PANEL | | MUST INCLUDE AN EQUIPMENT GROUNDING CONDUCTOR. IF THE | | CONDUCTORS ARE RUN UNDERGROUND FROM THE METER TO THE | | INTERIOR PANEL, AND THAT PANEL HAS A MAIN BREAKER, THE | | CONDUCTORS MUST NOT EXCEED 8 FEET IN LENGTH BEFORE | | TERMINATION TO THE MAIN BREAKER. PROVIDE CLARIFICATION | | AND/OR CORRECTION. NEC 230.70, 250.122; FBC RE E3601.6, | | E3704.6, 3607.3.1 | | 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | 3. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS | | SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8(A)(9); FBC RE E3902.9 | | 4. NOTE 12 STATES THAT LIGHTING IN CLOTHES CLOSETS | | SHALL COMPLY WITH NEC 410.8, WHICH IS NOT THE CORRECT | | CODE. PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 | | 5. NOTE 18 STATES THAT RECEPTACLES SHALL BE TAMPER | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-03-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-03-25 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-03-05 |
Time |
13:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-02-12 |
Time |
|
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-01-17 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-01-02 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-12-03 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2019-10-21 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-09-26 |
Time |
14:41 |
Sent To |
|
|
Notes |
2019-10-17 18:07:39 | TO HM DESK | | | 2019-09-27 14:41:36 | R35 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2020-02-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-11 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-02-11 |
Time |
16:06 |
Sent To |
|
|
Notes |
2020-02-11 16:07:02 | $9,401.07 PAID. MU-2020-000979. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-19 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-19 |
Time |
15:55 |
Sent To |
|
|
Notes |
2019-12-19 15:55:55 | IMPACT FEES - | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-17 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-17 |
Time |
14:27 |
Sent To |
|
|
Notes |
2019-10-17 14:29:17 | IMPACT FEES - PAPER SUBMITTALS | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2020-03-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-24 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-24 |
Time |
08:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2020-02-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-11 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-02-12 |
Time |
11:41 |
Sent To |
I |
|
Notes |
2020-02-12 13:07:51 | 3RD REVIEW FBC-2017 MECHANICAL | | PERMIT #19091104 | | 2/12/20 | | | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | SHEET AC-1: THE AC PLANS HAVE BEEN RESUBMITTED WITHOUT | | THE SIGNATURE OF THE CONTRACTOR, OR THE SIGNATURE AND | | SEAL AND TITLE BLOCK OF THE FL. LICENSED DESIGN | | PROFESSIONAL WHO PREPARED THE DRAWING. SEE COMMENT #1 | | FROM THE 1ST & 2ND REVIEWS PRINTED BELOW. | | | | 1) THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON THE MECHANICAL PLAN SHEET | | AC-1- SECTION 107.2.1 WPB. IF THE DESIGNER IS A FL. | | LICENSED ARCHITECT OR ENGINEER, HE/SHE SHALL ALSO | | PROVIDE AN ORIGINAL SEAL AND WET SIGNATURE PER FL. | | STATUE AND SECTIONS 61G15-16.003 AND 23.002 FAC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | 2020-02-11 16:12:00 | ENTERED THIS REVIEW STOP BY MISTAKE. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2020-01-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-01-02 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-01-02 |
Time |
09:33 |
Sent To |
I |
|
Notes |
2020-01-02 09:33:40 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #19091104 | | 1/2/20 | | | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | SHEET AC-1: THE AC PLANS HAVE BEEN RESUBMITTED WITHOUT | | THE SIGNATURE OF THE CONTRACTOR, OR THE SIGNATURE AND | | SEAL AND TITLE BLOCK OF THE FL. LICENSED DESIGN | | PROFESSIONAL WHO PREPARED THE DRAWING. SEE COMMENT #1 | | FROM THE 1ST REVIEW PRINTED BELOW. | | | | 1) THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON THE MECHANICAL PLAN SHEET | | AC-1- SECTION 107.2.1 WPB. IF THE DESIGNER IS A FL. | | LICENSED ARCHITECT OR ENGINEER, HE/SHE SHALL ALSO | | PROVIDE AN ORIGINAL SEAL AND WET SIGNATURE PER FL. | | STATUE AND SECTIONS 61G15-16.003 AND 23.002 FAC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-10-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-10-21 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-10-21 |
Time |
11:13 |
Sent To |
|
|
Notes |
2019-10-21 11:15:36 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #19091104 | | 10/21/19 | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON THE MECHANICAL PLAN SHEET | | AC-1- SECTION 107.2.1 WPB. IF THE DESIGNER IS A FL. | | LICENSED ARCHITECT OR ENGINEER, HE/SHE SHALL ALSO | | PROVIDE AN ORIGINAL SEAL AND WET SIGNATURE PER FL. | | STATUE AND SECTIONS 61G15-16.003 AND 23.002 FAC. | | | | 2) THE ENERGYGAUGE FORM R405 IS MISSING FROM THE ENERGY | | COMPLIANCE SUBMITTAL- SECTION R405.2 FBC EC. | | | | 3) PROVIDE THE MANUAL J WORKSHEETS WITH THE AC SYSTEM | | SIZING CALCULATIONS- SECTION R403.7.1 FBC EC. | | | | 4) AC-1: INDICATE THE SIZE OF THE RETURN DUCT FROM THE | | MASTER BEDROOM TO THE 20X18 RAG, AND THE SIZE OF THE | | DUCT FROM THE RAG TO THE AIR HANDLER- SECTION M1602.2 | | FBC RES. | | | | 5) AC-1: THE RETURN TRANSFER DUCTS FROM BEDROOMS 3, 4, | | & 5 ARE UNDERSIZED PER SECTION M1602.3 FBC RES- THE | | RETURN DUCT DIAMETERS SHALL BE 1.5 TIMES THE DIAMETERS | | OF THE SUPPLY DUCTS. | | | | 6) AC-1 EXHAUST VENTILATION AT A RATE OF 100 CFMS | | INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED | | FOR THE KITCHEN- TABLE M1507.4 FBC RES. PLEASE SEE | | SECTION M1503.1 FOR RANGE HOOD REQUIREMENTS, AND | | M1503.4 FOR MAKEUP AIR. | | | | 7) AC-1 VERIFY COMPLIANCE WITH SECTION R403.3.6 | | AIR-HANDLING UNITS IN ATTICS: | | | | AIR-HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC | | WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION | | R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR | | COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING | | CONDITIONS ARE MET: | | | | 1.THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | | 2.A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT DOWN | | THE UNIT WHEN THE CONDENSATION DRAIN IS NOT WORKING | | PROPERLY. | | | | 3.THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | REPLACE THE AIR HANDLER. | | | | 4.A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | CAPITALS, IN 16-POINT TYPE, WITH THE TITLE AND FIRST | | PARAGRAPH IN BOLD: | | | | NOTICE TO HOMEOWNER | | A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR | | HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT | | AND ECONOMIC OPERATION OF THE AIRCONDITIONING SYSTEM, | | YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED. | | YOUR AIR-CONDITIONING SYSTEM IS EQUIPPED WITH ONE OR | | BOTH OF THE FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU | | WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR | | (2) A DEVICE THAT WILL SHUT DOWN THE SYSTEM WHEN THE | | CONDENSATION DRAIN IS NOT WORKING. TO LIMIT POTENTIAL | | DAMAGE TO YOUR HOME, AND TO AVOID DISRUPTION OF | | SERVICE, IT IS RECOMMENDED THAT YOU ENSURE PROPER | | WORKING ORDER OF THESE DEVICES BEFORE EACH SEASON OF | | PEAK OPERATION. | | | | 8) AC-1: PROVIDE ENGINEERING FOR INSTALLATION OF THE | | CONDENSER PAD AND MOUNTING OF THE CONDENSER- SECTIONS | | M1305.1.4.1 AND M1401.4 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2020-03-20 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2020-03-20 |
Time |
07:02 |
Rev Time |
0.00 |
Received By |
jbaker |
Date |
2020-03-20 |
Time |
07:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2020-02-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-02-11 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-02-11 |
Time |
16:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-12-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-19 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-19 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-11 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-11 |
Time |
10:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-17 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-17 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-12-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-12-11 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-12-11 |
Time |
10:45 |
Sent To |
|
|
Notes |
2019-12-11 10:45:37 | SHINGLES FL10124-R22 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-10-17 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-10-17 |
Time |
14:26 |
Sent To |
|
|
Notes |
2019-10-17 14:27:29 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL): | | | | A) ROOF SHINGLES. PROVIDE FLORIDA PRODUCT APPROVAL | | COVER PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. NEED | | COVER PAGE TO VERIFY CURRENT CODE AND IF THE PRODUCT IS | | APPROVED. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2020-03-16 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-03-16 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-03-16 |
Time |
16:11 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-12-13 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2019-12-13 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2019-12-13 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2019-10-07 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2019-10-04 |
Time |
09:12 |
Sent To |
I |
|
Notes |
2019-10-04 09:46:36 | 10/4/19 | | | | I SPOKE WITH THE APPLICANT REGARDING LANDSCAPING. HE | | WILL BE SUBMITTING A CONDITIONAL PERMIT FOR | | LANDSCAPING. ONCE I RECIEVE THE CONDITIONAL PERMIT I | | WILL CONTINUE TO ROUTE THE PERMIT. |
|
|