Plan Review Stops For Permit 19090742 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-11-18 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-11-18 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-10-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-11 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-10 |
Time |
11:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-11-14 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-11-14 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-11-14 |
Time |
08:13 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-10-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-10-09 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-10-08 |
Time |
15:48 |
Sent To |
|
|
Notes |
2019-10-09 15:43:14 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | ALARMS, OR PROVIDE A NOTE REQUIRING COMPLIANCE. IF NONE | | ARE EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. | | FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | 2. THE CIRCUIT FOR THE RECEPTACLE OUTLET LOCATED IN THE | | POWDER ROOM IS NOT DETAILED. A MINIMUM OF ONE 20 AMPERE | | BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM | | RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER | | OUTLETS. PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE | | E3703.4 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2019-09-27 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-09-27 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-09-27 |
Time |
11:13 |
Sent To |
PC |
|
Notes |
2019-09-27 11:14:43 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | CONDITIONS: | | | | A. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR | | CLEAR GLASS WITH LOW-E COATING. TINTED OR PRIVACY GLASS | | IS PROHIBITED. | | B. THE NEW WINDOWS SHALL BE INSET WITHIN THE WINDOW | | FRAME OPENING. TRY TO MATCH THE INSET OF THE ORIGINAL | | WOOD WINDOWS ELSEWHERE ON THE PROPERTY. | | C. ALL WINDOW FRAMES SHALL BE WHITE IN COLOR. | | D. THE WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE | | DIMENSIONAL MUNTINS. | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-11-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-11-18 |
Time |
08:10 |
Rev Time |
|
Received By |
cthroop |
Date |
2019-10-22 |
Time |
14:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-10-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-11 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-19 |
Time |
11:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2019-11-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-11-18 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-11-18 |
Time |
08:09 |
Sent To |
|
|
Notes |
2019-11-18 08:10:06 | PLANS STAMPERD NO FEES DUE. NO MU NUMBER. CT |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2019-10-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-11 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-10 |
Time |
11:42 |
Sent To |
|
|
Notes |
2019-10-11 07:46:47 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF. CT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-11-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-11-05 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-11-05 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-10-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-10-04 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-10-04 |
Time |
16:57 |
Sent To |
|
|
Notes |
2019-10-04 17:19:36 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #19090742 | | 10/4/19 | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE AN ENERGY COMPLIANCE REPORT FOR THE NEW | | ADDITION- SECTION R101.5 FBC EC. | | | | 2) GAS DRYER: | | | | A) SUBMIT SPECS FOR THE DRYER- SECTION G2408.1 FBC RES. | | | | B) PROVIDE A GAS PIPING ISOMETRIC DRAWING- SECTION | | G2413.1 FBC RES. | | | | C) PROVIDE COMBUSTION AIR CALCULATIONS AND INDICATE HOW | | THE AIR WILL BE PROVIDED- SECTION G2407.1 FBC RES. | | | | D) PROVIDE DRYER VENTING PLANS- SECTION G2427.1 FBC | | RES. | | | | 3) PROVIDE A TOILET EXHAUST FAN SCHEDULE AND SHOW THE | | EXHAUST DUCT RUN AND TERMINATION LOCATION- SECTION | | M1501.1 & M1507.4 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-10-24 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-10-24 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-10-24 |
Time |
15:57 |
Sent To |
|
|
Notes |
2019-10-24 15:57:14 | PLUMBING COMMENTS: APPROVED | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-09-24 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-09-24 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-09-24 |
Time |
16:45 |
Sent To |
|
|
Notes |
2019-09-24 16:46:15 | 09/24/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2019-10-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-11 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-10 |
Time |
11:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-09-27 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-09-27 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-09-27 |
Time |
11:13 |
Sent To |
|
|
Notes |
|
|