Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-26 Cont ID  
Sent By jgomez Date 2019-09-26 Time 13:02 Rev Time 0.00
Received By jgomez Date 2019-09-26 Time 12:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-09-18 Cont ID  
Sent By jgomez Date 2019-09-18 Time 15:35 Rev Time 0.00
Received By jgomez Date 2019-09-18 Time 15:13 Sent To  
Notes
2019-09-18 15:40:44RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1-- FLAT ROOF NOA 1--0622.21 SUBMITTED: SELECTED
 ASSEMBLY ON PAGE 12 OF 19 DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED AND SEALED
 RAS 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER
 AND CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7
 ON LAST PAGE OF NOA. NEED THE CALCULATIONS TO MEET THE
 DESIGN PRESSURES REQUIRED BY SEC. R301.2.1
 FBC-RESIDENTIAL.
  
  
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-26 Cont ID  
Sent By jgomez Date 2019-09-26 Time 13:02 Rev Time 0.00
Received By jgomez Date 2019-09-26 Time 12:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-18 Cont ID  
Sent By jgomez Date 2019-09-18 Time 15:41 Rev Time 0.00
Received By jgomez Date 2019-09-17 Time 12:55 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved