2019-09-18 18:52:54 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL10497-R6 | | SUBMITTED: | | SELECTED ASSEMBLY W-41 DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES. THE DESIGN PRESSURES OF | | BONDED ROOF ASSEMBLIES NEED TO MEET OR EXCEED THE | | DESIGN PRESSURES FOR ALL ROOF ZONES. ASSEMBLY W-41 | | DOESN'T MEET HE DESIGN PRESSURES FOR ALL ROOF ZONES. | | THEREFORE, ANOTHER ASSEMBLY NEEDS TO BE SELECTED. SEE | | LIMITATION #5.8 ON PAGE 4 OF 5 OF PRODUCT APPROVAL | | SUBMITTED. NOTE: ACCORDING TO SEC. R301.2.1.4 | | FBC-RESIDENTIAL, THIS BUILDING IS LOCATED IN EXPOSURE | | "D". TAKE THIS INTO CONSIDERATION WHEN SELECTING | | ANOTHER BONDED ASSEMBLY. THE DESIGN PRESSURES FOR | | BUILDINGS LOCATED IN EXPOSURE "D" ARE HIGHER. | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-09-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-09-19 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-09-19 |
Time |
08:14 |
Sent To |
|
|
Notes |
2019-09-19 08:18:27 | CALLED CONTRACTOR. TALKED TO AARON. HE SAID THEY WILL | | USE ASSEMBLY W-42 SINCE IT WILL MEET THE DESIGN | | PRESSURE FOR ALL ROOF ZONES. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-09-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-09-18 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-09-17 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |