Plan Review Details - Permit 19090440
Plan Review Stops For Permit 19090440
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-07 Cont ID  
Sent By jgomez Date 2019-10-07 Time 10:47 Rev Time 0.00
Received By cthroop Date 2019-10-03 Time 16:12 Sent To  
Notes
2019-10-07 10:49:22BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE TWO COPIES OF FLORIDA PRODUCT APPROVAL
 FL29622 FOR ENGINEERED FLOOD VENTS, REVIEWED AND
 APPROVED BY DESIGNER.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-09-26 Cont ID  
Sent By fmittner Date 2019-09-26 Time 10:56 Rev Time 0.00
Received By fmittner Date 2019-09-26 Time 10:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-07 Cont ID  
Sent By cthroop Date 2019-10-07 Time 11:31 Rev Time 0.00
Received By cthroop Date 2019-09-18 Time 15:22 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2019-10-07 Cont ID  
Sent By cthroop Date 2019-10-07 Time 10:49 Rev Time 0.00
Received By cthroop Date 2019-10-07 Time 10:49 Sent To  
Notes
2019-10-07 10:56:48NFIP REVIEW - ELEVATION CERTIFICATE
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. EC FOR ACCESSORY STRUCTURE.
  
 1A. COMPLETE SECTION C2 (E) LOWEST ELEVATION OF
 MACHINERY OR EQUIPMENT.
 1B. ELEVATION CERTIFICATE IS BASED ON A FIRM. DESIGN
 FLOOD ELEVATION (DFE) OF C2 (E) SHALL BE 8.4 FEET NAVD.
 YOU MAY WISH TO UTILIZE THE FLOOD INSURANCE STUDY. THIS
 DFE WOULD BE 8.3 FEET NAVD BASED ON TRANSECT LINE 11 OF
 THE FIS.
  
 2. EC FOR NEW SINGLE FAMILY RESIDENCE.
  
 2A. THE BASE FLOOD ELEVATION (BFE) WAS ESTABLISHED BY A
 FLOOD INSURANCE RATE MAP. THIS ELVATION IS STATED AS 6
 & 7 FEET NAVD IN SECTION B9 OF THE ELVATION CERTIFICATE
 (EC). THIS ELEVATION SHALL BE SET AT 7.4 FEET UNLESS A
 FLOOD INSURANCE STUDY (FIS) IS USED TO ESTABLISH THE
 BFE.
 2B. THE BFE BASED ON THE FIS SHALL BE SET AT 7.3 FEET
 NAVD BASED ON THE PARCEL'S LOCATION TO TRANSECT LINE
 #11 OF THE FIS DATED OCT. 5, 2017.
 2C. DUE TO THE CITY'S REQUIREMENT OF A TWO FOOT
 FREEBOARD THE DFE SHALL BE 9.3 FEET NAVD.
 2S. TOP OF SLAB IS SHOWN AS 8.83 FEET NAVD WITH A 2
 INCH ALLOWANCE FOR FLOORING.
 2D. THE FINISHED FLOOR ELEVATION IS 9.0 FEET NAVD AS
 STATED ON THE CONSTRUCTION DRAWINGS.
  
 3. SECTION C2(E) IS REQUIRED.
  
  
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-10-07 Cont ID  
Sent By cthroop Date 2019-10-07 Time 10:39 Rev Time 0.00
Received By cthroop Date 2019-10-03 Time 16:12 Sent To  
Notes
2019-10-07 10:47:29SIGNATURE AND SEAL REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE FOLLOWING PLAN PAGES HAVE NO SIGNATURE AND SEAL.
 A-102.0, A-201 & A-601.0
  
 DIGITAL REVIEW
  
 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH
 FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY
 DIGITAL SIGATURES AND SEALS PER FS 668.003.
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2019-09-26 Cont ID  
Sent By fmittner Date 2019-09-26 Time 10:56 Rev Time 0.00
Received By fmittner Date 2019-09-26 Time 10:56 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved