Plan Review Stops For Permit 19090434 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-02-18 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-02-18 |
Time |
11:43 |
Sent To |
|
|
Notes |
2022-02-18 11:44:11 | HISTORIC APPROVED WITHOUT A KITCHEN, NOT A LEGAL UNIT, | | UPDATED PERMIT. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2020-01-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-01-07 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-01-07 |
Time |
13:19 |
Sent To |
|
|
Notes |
2020-01-07 13:23:33 | NO ADDRESS TO BE CREATED AS AT THIS TIME. ZONING DOES | | NOT ALLOW FOR MORE THAN ONE UNIT, SHOULD THIS CHANGE A | | NEW ADDRESS CAN BE CREATED. CP | | | | 947 39TH COURT IS PERMITTED TO HAVE ONLY ONE DWELLING | | UNIT. IT CANNOT HAVE ITS OWN ADDRESS. | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | PLANNING DIVISION | | [email protected] | OFFICE: 561.822.1428 | TTY: | | 800.955.8771 | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | FL 33402 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-01 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-01 |
Time |
14:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-01-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-29 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-22 |
Time |
09:34 |
Sent To |
|
|
Notes |
2022-01-29 08:30:04 | BUILDING PLAN REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | 3RD REVIEW | | | | RESULTS: DENIED | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | PREVIOUS COMMENTS. | | | | | | 2ND REVIEW COMMENTS | | ADDITION AND GUEST HOUSE 19080288 AND 19090434 | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) | | 2) | | 3) | | 4) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE EXTERIOR SWING DOORS. (NOT | | SUBMITTED FOR 3RD REDVIEW) | | 5) | | 6) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-26 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-26 |
Time |
10:53 |
Sent To |
|
|
Notes |
2020-03-26 10:54:02 | ADDITION AND GUEST HOUSE 19080288 AND 19090434 | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE THE MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE ROOFING SYSTEMS TO BE USED. | | 2) PLEASE PROVIDE THE MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVAL FOR THE MULL BAR FOR THE CONNECTION OF | | THE 2 WINDOWS MARKED "W4" MASTER BEDROOM. | | 3) PLEASE SHOW THE WALL AND CEILING INSULATION "R" | | VALUE AND INSULATION TYPE TO MATCH THE ENERGY CALCS. | | (ENERGY CALCS NOT YET PROVIDED). | | 4) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE SLIDING GLASS DOORS AND | | EXTERIOR SWING DOORS ( DOCUMENTS PROVIDED FOR THE | | EXTERIOR SWING DOOR IS NOT A COMPLETE MIAMI DADE OR | | FLORIDA STATE PRODUCT APPROVAL) | | 5) DRAWING A2 - PLEASE CHECK THE WINDOW AND DOOR | | SCHEDULE - MARKS W4, W7 AND D1 DO NOT MATCH THE FLOOR | | PLAN. | | 6) GUEST HOUSE EGRESS DOOR WIDTH AT 32 INCHES IS NOT A | | WIDE ENOUGH OPENING - WIDTH NEEDS TO COMPLY WITH FBC | | R311.2 EGRESS DOOR. | | NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED FOR | | EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE | | SIDE-HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT | | LESS THAN 32 INCHES (813 MM) WHERE MEASURED BETWEEN THE | | FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 | | DEGREES. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
14:17 |
Sent To |
|
|
Notes |
2019-09-12 15:19:23 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SHUTTERS REQUIRED FOR ALL WINDOWS PER NOTE ON PLAN. | | 2. SUBMIT SHUTTER SCHEDULE. | | 3. PROVIDE PRODUCT APPROVALS FOR SHUTTERS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE SHUTTER SUBMITTALS. | | | | 4. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND EXTERIOR | | DOORS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | 5. PROVIDE ENERGY SUBMITTAL. | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | 6. R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | (MANDATORY). | | | | 7. PROVIDE SITE DRAINAGE PLAN. | | FBC R401.3 SITE DRAINAGE | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | COMPLIANCE WITH FBC R401.3 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-03-26 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-03-26 |
Time |
14:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
14:18 |
Sent To |
|
|
Notes |
2019-09-12 15:43:14 | COMMENTS TRANSFERRED FROM 19080288 (MAIN HOUSE | | ADDITION) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. NOTE ON RISER DIAGRAM STATES THAT LIGHTING IN | | CLOSETS TO COMPLY WITH 410-8. THIS CODE SECTION DOES | | NOT APPLY TO LIGHTING IN CLOSETS. PROVIDE CORRECTION. | | NEC 410.16; FBC RE E4003.12 | | 2. NOTE IN ELECTRICAL NOTES STATES THAT RECEPTACLES | | SHALL BE TAMPER RESISTANT PER NEC 406.11. THIS CODE | | SECTION DOES NOT APPLY TO TAMPER RESISTANT RECEPTACLES. | | NOTE ALSO QUOTES THE 2007 FBC AS CODE REFERENCE, WHICH | | IS NOT THE CURRENT CODE. PROVIDE CORRECTION. NEC | | 406.12; FBC RE E4002.14; FBC PREFACE, WPB FBC 107.2.1 | | 3. NOTE STATES THAT ALL BREAKERS SHALL HAVE AN AIC | | RATING OF 1000. PROVIDE CORRECTION. FBC RE E3606.3 | | 4. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1, | | 801.2, OR 901.2 AS APPLICABLE. | | 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | FBC EC C405.1, R404.1 | | 6. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. THE | | RECEPTACLE OUTLET SHALL BE LOCATED ON A WALL OR | | PARTITION THAT IS ADJACENT TO THE BASIN OR BASIN | | COUNTERTOP, LOCATED ON THE COUNTERTOP, OR INSTALLED ON | | THE SIDE OR FACE OF THE BASIN CABINET. PROVIDE | | CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE E3901.6 | | 7. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-04-13 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-04-13 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
15:46 |
Sent To |
|
|
Notes |
2019-09-12 15:47:13 | COMMENTS TRANSFERRED FROM 19080288 (MAIN HOUSE | | ADDITION) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | HISTORIC | | | | PROPERTY LOCATED IN HISTORIC DISTRICT. REQUIRES COA | | APPROVAL. QUESTIONS, CONTACT: FRIEDERIKE MITTNER AT | | (561) 822-1457 OR [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-02-01 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-02-01 |
Time |
14:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-01-31 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-01-31 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-01-21 |
Time |
07:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-04-13 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-03-16 |
Time |
11:46 |
Sent To |
|
|
Notes |
2020-04-04 15:44:41 | 04/04/2020 ROUTED TO R20 | 2020-03-17 11:46:22 | R20 | | | | **TRAVELLING TOGETHER 19080288 AND 19090434** |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
14:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-02-18 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-02-01 |
Time |
17:12 |
Sent To |
|
|
Notes |
2022-02-17 13:20:30 | RECEIPT MU-2022-05607 - $4199.63 PAID | 2022-02-01 17:12:48 | 2/1/22 EMAILED IMPACT FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
14:18 |
Sent To |
|
|
Notes |
2019-09-12 15:44:06 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2020-06-17 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2020-06-17 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2020-06-17 |
Time |
13:53 |
Sent To |
|
|
Notes |
2020-06-17 13:56:17 | 20060387 IS THE RE-SUB FOR 19090434 MECHANICAL ONLY HM. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2020-03-24 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-03-24 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-03-24 |
Time |
13:34 |
Sent To |
|
|
Notes |
2020-03-24 13:35:59 | PLEASE PROVIDE THE INFORMATION REQUESTED ON THE 1ST | | CYCLE REVIEW. | | | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | | | COMMENTS TRANSFERRED FROM 19080288 (MAIN HOUSE | | ADDITION) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | MECHANICAL PLAN REVIEW FAIL | | | | 1 - NEED MANUAL J OR OTHER APPROVED HEATING AND COOLING | | CALCULATION METHODOLOGIES. PER 2017 FLORIDA BUILDING | | CODE SEC RESIDENTIAL M1401.3 EQUIPMENT AND APPLIANCE | | SIZING. | | | | 2 - NEED ENERGY TO SHOW COMPLIANCE WITH 2017 FLORIDA | | BUILDING CODE PER 2017 FLORIDA BUILDING CODE - ENERGY | | CONSERVATION SEC R101.5.1 COMPLIANCE MATERIALS | | | | CHRIS MONTELLO | | 561-805-6733 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
14:18 |
Sent To |
|
|
Notes |
2019-09-12 15:20:22 | COMMENTS TRANSFERRED FROM 19080288 (MAIN HOUSE | | ADDITION) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | MECHANICAL PLAN REVIEW FAIL | | | | 1 - NEED MANUAL J OR OTHER APPROVED HEATING AND COOLING | | CALCULATION METHODOLOGIES. PER 2017 FLORIDA BUILDING | | CODE SEC RESIDENTIAL M1401.3 EQUIPMENT AND APPLIANCE | | SIZING. | | | | 2 - NEED ENERGY TO SHOW COMPLIANCE WITH 2017 FLORIDA | | BUILDING CODE PER 2017 FLORIDA BUILDING CODE - ENERGY | | CONSERVATION SEC R101.5.1 COMPLIANCE MATERIALS | | | | CHRIS MONTELLO | | 561-805-6733 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-03-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-03-27 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-03-27 |
Time |
17:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
14:17 |
Sent To |
|
|
Notes |
2019-09-12 15:45:08 | COMMENTS TRANSFERRED FROM 19080288 (MAIN HOUSE | | ADDITION) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | 08/23/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-01 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-01 |
Time |
14:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2022-01-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-29 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-22 |
Time |
09:34 |
Sent To |
|
|
Notes |
2022-01-29 08:32:09 | BUILDING PLAN REVIEW ROOFING | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | 3RD REVIEW | | | | RESULTS: DENIED | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | PREVIOUS COMMENTS. | | | | | | 2ND REVIEW COMMENTS | | ADDITION AND GUEST HOUSE 19080288 AND 19090434 | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE THE MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE ROOFING SYSTEMS TO BE USED. | | (PROVIDE COVER SHEETS FOR FL2533-R26) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-26 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-26 |
Time |
10:54 |
Sent To |
|
|
Notes |
2020-03-26 10:54:37 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
14:18 |
Sent To |
|
|
Notes |
2019-09-12 15:46:03 | BUILDING PLAN REVIEW - ROOFING | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING SUB-PERMIT REQUIRED. | | | | 2. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | COMPONENTS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-02-01 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-02-01 |
Time |
14:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-01-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-01-29 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-01-29 |
Time |
07:14 |
Sent To |
|
|
Notes |
2022-01-29 08:32:56 | SIGNATURE REVIEW | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | INSPECTOR BN4338 | | BUILDING OFFICIAL BU1635 | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | DEVELOPMENT SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NEC2017 | | | | 1ST REVIEW | | RESULTS: DENIED | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | SIGNATURE. | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | WET SEAL AND SIGNATURE TO: | | | | BUILDING DIVISION, FIRST FLOOR | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST | | WEST PALM BEACH, FL 33401 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-02-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2022-01-31 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2022-02-02 |
Time |
09:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2021-09-09 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-04-13 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-04-13 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-12 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-12 |
Time |
14:18 |
Sent To |
|
|
Notes |
2019-09-12 15:47:59 | COMMENTS TRANSFERRED FROM 19080288 (MAIN HOUSE | | ADDITION) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | ZONING | | | | LOT COVERAGE AND FAR NOT IDENTIFIED. QUESTIONS CONTACT | | FRIEDERIKE MITTNER AT (561) 822-1457 | | |
|
|