Plan Review Details - Permit 19090158
Plan Review Stops For Permit 19090158
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 10:18 Rev Time 0.00
Received By jwitmer Date 2019-09-30 Time 10:07 Sent To  
Notes
2019-09-30 10:18:47BUILT IN 1988.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 11:10 Rev Time 0.00
Received By jwitmer Date 2019-09-30 Time 10:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-09-23 Cont ID  
Sent By jleahy Date 2019-09-23 Time 09:05 Rev Time 0.00
Received By jleahy Date 2019-09-20 Time 11:39 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2019-09-23 Cont ID  
Sent By jleahy Date 2019-09-23 Time 09:06 Rev Time 0.00
Received By jleahy Date 2019-09-23 Time 09:06 Sent To  
Notes
2019-09-23 09:06:41PHONE AND DATA ONLY JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-10-09 Cont ID  
Sent By pleduc Date 2019-10-09 Time   Rev Time 0.00
Received By pleduc Date 2019-10-09 Time 12:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-09-11 Cont ID  
Sent By pleduc Date 2019-09-11 Time   Rev Time 0.00
Received By pleduc Date 2019-09-11 Time 11:18 Sent To  
Notes
2019-09-11 16:37:49THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET A 219 - THERE ARE SYMBOLS; CIRCLES, SQUARES
 AND OCTAGONS, WITH NUMBERS IN THEM BUT NO LEGEND
 IDENTIFYING WHAT THEY REPRESENT.
  
 PLEASE REVIEW AND CLARIFY OF PROVIDE THE APPLICABLE
 LEGEND.
  
  
  
 2) SHEET A 219 - ELEVATOR EXIT LOBBY DOOR EXIT 1971, IS
 NOT INDICATED WITH HARDWARE IN COMPLIANCE WITH NFPA
 101, CH 7 MEANS OF EGRESS.
  
 7.4.1.6 ELEVATOR LANDING AND LOBBY EXIT ACCESS.
 7.4.1.6.1 EACH ELEVATOR LANDING AND LOBBY SHALL HAVE
 ACCESS TO AT
 LEAST ONE EXIT.
 7.4.1.6.2 THE ELEVATOR LANDING AND LOBBY EXIT ACCESS
 REQUIRED BY
 7.4.1.6.1 SHALL NOT REQUIRE THE USE OF A KEY, A TOOL,
 SPECIAL
 KNOWLEDGE, OR SPECIAL EFFORT, UNLESS PERMITTED BY
 7.4.1.6.3.
 7.4.1.6.3 DOORS SEPARATING THE ELEVATOR LOBBY FROM THE
 EXIT ACCESS
 REQUIRED BY 7.4.1.6.1 SHALL BE PERMITTED TO BE
 ELECTRONICALLY LOCKED
 IN ACCORDANCE WITH 7.2.1.6.3.
  
  
 3) THERE DOES NOT APPEAR TO BE A DOOR SCHEDULE
 INDICATING EACH DOOR LOCATION, TYPE, HARDWARE GROUP,
 LOCKS & LATCHES , ETC.
  
 SHEET A 219 HAS A DOOR TYPE SCHEDULE AND HARDWARE
 GROUPS BUT NO CORRESPONDING DOOR LOCATIONS.
  
 PLEASE REIVEW AND PROVIDE.
  
  
 4) SHEET A 219 - THERE IS AN INDICATION OF DOOR
 SECURITY EQUIPMENT.
  
 ALL ACCESS CONTROL SHALL BE UNDER SEPARATE PERMIT, SHOP
 DRAWINGS, EQUIPMENT SPECS AND COMPLY WITH NFPA 101, CH
 7 , MEANS OF EGRESS, WERE APPLICABLE.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT AND
 COMPLIANCE.
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-09 Cont ID  
Sent By lmarchan Date 2019-10-09 Time 13:25 Rev Time 0.00
Received By lmarchan Date 2019-10-07 Time 07:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-07 Cont ID  
Sent By cpuell Date 2019-10-07 Time 13:30 Rev Time 0.00
Received By cpuell Date 2019-09-09 Time 06:09 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 10:17 Rev Time 0.00
Received By jwitmer Date 2019-09-30 Time 10:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-09-23 Cont ID  
Sent By ccole Date 2019-09-23 Time 16:04 Rev Time 0.00
Received By ccole Date 2019-09-23 Time 16:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-09-27 Cont ID  
Sent By shill Date 2019-09-27 Time 07:10 Rev Time 0.00
Received By shill Date 2019-09-13 Time 11:41 Sent To  
Notes
2019-09-27 07:10:38REVIEWED REMOTELY BY TIM HUNT
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 11:09 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2019-09-30 11:11:37ARCHITECTURAL SHEETS CHECKED FOR ELECTRONIC
 SIGNATURES.JW 09/30/2019

Review Stop Z ZONING
Rev No 1 Status N Date 2019-10-03 Cont ID  
Sent By aaponte Date 2019-10-03 Time 08:03 Rev Time 0.00
Received By aaponte Date 2019-10-03 Time 08:03 Sent To  
Notes
***NONE***