Plan Review Details - Permit 19081526
Plan Review Stops For Permit 19081526
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-10-28 Cont ID  
Sent By cthroop Date 2019-10-28 Time 07:15 Rev Time 0.00
Received By cthroop Date 2019-10-25 Time 15:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-09-23 Cont ID  
Sent By cthroop Date 2019-09-23 Time 10:37 Rev Time 0.00
Received By cthroop Date 2019-09-20 Time 16:17 Sent To  
Notes
2019-09-23 10:59:59BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PLAN PAGE D1 SHOWS WINDOW IN NEW M-BATH TO BE
 REPLACED WITH A 6068 SGD. PLAN PAGE S1 SHOWS SAME
 WINDOW BEING REPLACED BY A DOUBLE FRENCH DOOR. PLEASE
 CLARIFY.
  
 2. DOOR #2 ON DRAWING DOEWS NOT MATCH DOOR #2 ON DOOR
 SCHEDULE. PLEASE CLARIFY.
  
 3. INTERIOR DOOR #5 ON PLAN INDICATES A 3'0" 6'8" SGD.
  
 PLEASE REVIEW PLANS AND REMOVE ANY PRODUCTS THAT DO NOT
 PERTAIN TO THIS SCOPE OF WORK.
  
 4. PROVIDE ENERGY SUBMITTAL.
 FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3
 STORIES.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-10-21 Cont ID  
Sent By ppetty Date 2019-10-21 Time 11:40 Rev Time 0.00
Received By ppetty Date 2019-10-21 Time 11:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-09-19 Cont ID  
Sent By jpearson Date 2019-09-19 Time 08:40 Rev Time 0.00
Received By jpearson Date 2019-09-19 Time 08:07 Sent To  
Notes
2019-09-19 08:40:54CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. MATH IN PROVIDED CALCULATION IS NOT CORRECT. NEC
 220; FBC RE E3602.2
 2. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM
 BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET
 FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE
 R314.3(4), NFPA 72:29.8.3.4
 3. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS
 SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8(A)(9); FBC RE E3902.9
 4. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB
 FBC 107.2.1
 5. NOTE 3 STATES THAT RECEPTACLES SHALL BE TAMPER
 RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT
 APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE
 CORRECTION. NEC 406.12; FBC RE E4002.14
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2019-11-06 Cont ID  
Sent By fmittner Date 2019-11-06 Time 14:10 Rev Time 0.00
Received By fmittner Date 2019-11-06 Time 14:10 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2019-10-23 Cont ID  
Sent By fmittner Date 2019-10-23 Time 16:23 Rev Time 0.00
Received By fmittner Date 2019-10-23 Time 16:22 Sent To  
Notes
2019-10-23 16:24:04WINDOW SPEC SUPPLIED AND CIRCLED FOR SERIES 605 DOES
 NOT OFFER EXTERIOR OGEE GRID, ANOTHER SERIES IN CATALOG
 (2500) OFFERS HISTORIC REQUIREMENT. PLEASE REVISE TO
 CORRECT PRODUCT.

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-09-09 Cont ID  
Sent By fmittner Date 2019-09-09 Time 12:25 Rev Time 0.00
Received By fmittner Date 2019-09-09 Time 12:25 Sent To  
Notes
2019-09-09 12:28:03PROPERTY LOCATED WITHIN NORTHBORO PARK HISTORIC
 DISTRICT. NEED WINDOW CLARIFFICATION.....FRAME COLOR,
 GLASS COLOR. ELEVATIONS NEED TO MATCH EXISITNG GRIDS
 (6/6) WITH DIMENSIONAL OGEE MUNTINS.
  
 QUESTIONS, CONTACT: FRIEDERIKE MITTNER AT (561)
 822-1457

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-11-06 Cont ID  
Sent By cpuell Date 2019-11-06 Time 14:35 Rev Time 0.00
Received By cpuell Date 2019-11-04 Time 11:16 Sent To  
Notes
2019-11-05 11:17:07RESUB ROUTED TO HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-28 Cont ID  
Sent By cthroop Date 2019-10-28 Time 08:22 Rev Time 0.00
Received By cthroop Date 2019-10-10 Time 14:37 Sent To  
Notes
2019-10-10 14:37:58R11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-23 Cont ID  
Sent By cthroop Date 2019-09-23 Time 11:00 Rev Time 0.00
Received By cthroop Date 2019-08-30 Time 13:59 Sent To  
Notes
2019-08-30 14:00:03R16

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-10-28 Cont ID  
Sent By cthroop Date 2019-10-28 Time 08:22 Rev Time 0.00
Received By cthroop Date 2019-10-25 Time 15:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-09-23 Cont ID  
Sent By cthroop Date 2019-09-23 Time 10:31 Rev Time 0.00
Received By cthroop Date 2019-09-20 Time 16:17 Sent To  
Notes
2019-09-23 10:37:26MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE MECHANICAL PLAN.
 . PROVIDE COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE
 OF MECHANICAL WORK TO BE DONE. WPB AMEND. TO FBC
 SEC.107.2.1.
  
 2. PROVIDE ENERGY SUBMITTAL.
 FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3
 STORIES.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
 (MANDATORY).
 THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY
 PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND
 CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT
 BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY.
 FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)]
 REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN
 ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND
 NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD
 CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE
 LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A
 DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT
 THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE
 BUILDER ACCURATELY REFLECTS THE PLANS AND
 SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE
 FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE
 FOUND IN APPENDIX C.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-10-21 Cont ID  
Sent By gjohnson Date 2019-10-21 Time 15:13 Rev Time 0.00
Received By gjohnson Date 2019-10-21 Time 15:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-09-12 Cont ID  
Sent By lcrespo Date 2019-09-12 Time 17:07 Rev Time 0.00
Received By lcrespo Date 2019-09-12 Time 17:07 Sent To  
Notes
2019-09-12 17:09:0909/11/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  