Plan Review Details - Permit 19081187
Plan Review Stops For Permit 19081187 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-24 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-23 |
Time |
17:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-16 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-13 |
Time |
15:04 |
Sent To |
|
|
Notes |
2019-09-16 11:09:27 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW WINDOW AND DOORS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | 2. PROVIDE SHUTTER SCHEDULE PER NOTE ON PLAN PAGE 1 OF | | 5. | | FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION OF | | OPENING PROTECTIVE DEVICES" OR PROVIDE ALL INFORMATION | | REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL SPREADSHEET): | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS?PAGE=2 | | | | WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE NOTE | | FACTORS THAT APPLY DEPENDING ON SUBSTRATE, EDGE | | DISTANCE AND FASTENER. FOR FASTENER, IF USING TAPCON, | | BE SPECIFIC AS TO WHICH TAPCON (TAPCON W/ADVANCED | | THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | | 3. PROVIDE ENERGY SUBMITTAL. | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | 4. DESIGNER TO SHOW LOCATION AND R VALUE OF INSULATION. | | R402.1 GENERAL (PRESCRIPTIVE). | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | REQUIREMENTS OF SECTIONS R402.1.1 THROUGH R402.1.4. | | | | R402.2 SPECIFIC INSULATION REQUIREMENTS (PRESCRIPTIVE). | | IN ADDITION TO THE REQUIREMENTS OF SECTION R402.1, | | INSULATION SHALL MEET THE SPECIFIC REQUIREMENTS OF | | SECTIONS R402.2.1 THROUGH R402.2.13. | | | | 5. ENGINEER OF RECORD SHALL PLACE STATEMENT ON PLAN | | THAT EXISTING RAFTERS CAN SUPPORT THE ADDITION LOAD OF | | THE NEW AHU. | | M1201.1SCOPE. | | THE PROVISIONS OF CHAPTERS 12 THROUGH 24 SHALL REGULATE | | THE DESIGN, INSTALLATION, MAINTENANCE, ALTERATION AND | | INSPECTION OF MECHANICAL SYSTEMS THAT ARE PERMANENTLY | | INSTALLED AND USED TO CONTROL ENVIRONMENTAL CONDITIONS | | WITHIN BUILDINGS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2019-11-01 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-11-01 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-11-01 |
Time |
12:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-10-21 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-10-21 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-10-21 |
Time |
08:31 |
Sent To |
|
|
Notes |
2019-10-21 09:38:09 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | (S) | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | 109.3 | | 2. CORRECTED. | | 3. CORRECTED. | | 4. CORRECTED. | | 5. CORRECTED. | | 6. CORRECTED. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-09-12 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-09-12 |
Time |
08:40 |
Sent To |
|
|
Notes |
2019-09-12 10:59:31 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | 109.3 | | 2. AFCI PROTECTION SHOWN IN NOTES IS NOT CODE | | COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | SERVICE IS ADEQUATE. LOAD CALCULATION PROVIDED IS NOT | | CODE COMPLIANT. SEE FBC RES. E3602. NEC 215.2, 220, | | 408.30; FBC RE E3602.2 | | 4. PROVIDE ACCURATE PANEL SCHEDULE INDICATING ANY NEW | | OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR | | THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | APPLICABLE TO COMPLY WITH CODE. PANEL SCHEDULE PROVIDED | | IN SOME LOCATIONS SHOWS THE INCORRECT WIRE SIZES FOR | | THE OVERCURRENT PROTECTION OF THE CIRCUIT. NEC 210.8, | | 210.12, 210.19, 210.20, 215.5, 408.4; WPB FBC 107.3.5; | | FBC RE E3706.2, E3902 | | 5. LOAD CALCULATION STATES THAT A 200 AMP SERVICE WILL | | BE PROVIDED. RISER DIAGRAM SHOWS A 150 AMP SERVICE | | BEING INSTALLED. PROVIDE CLARIFICATION AND CORRECTIONS | | AS NEEDED. NEC 215.5, 230, 250.50, 250.94, 408.30; FBC | | RE E3706.1, E3608.1, E3609.3; WPB FBC 107.2.1 | | 6. NOTE STATES THAT RECEPTACLES SHALL BE TAMPER | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-24 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-08 |
Time |
14:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-09-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-16 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-23 |
Time |
12:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-24 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-23 |
Time |
17:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-16 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-13 |
Time |
15:04 |
Sent To |
|
|
Notes |
2019-09-16 11:12:12 | MECHANICAL PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE ENERGY SUBMITTAL. INCLUDE MANUAL J | | CALCULATIONS. | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | 2. DESIGNER TO SHOW LOCATION AND R VALUE OF INSULATION. | | R402.1 GENERAL (PRESCRIPTIVE). | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | REQUIREMENTS OF SECTIONS R402.1.1 THROUGH R402.1.4. | | | | R402.2 SPECIFIC INSULATION REQUIREMENTS (PRESCRIPTIVE). | | IN ADDITION TO THE REQUIREMENTS OF SECTION R402.1, | | INSULATION SHALL MEET THE SPECIFIC REQUIREMENTS OF | | SECTIONS R402.2.1 THROUGH R402.2.13. | | | | 3. ENGINEER OF RECORD SHALL PLACE STATEMENT ON PLAN | | THAT EXISTING RAFTERS CAN SUPPORT THE ADDITION LOAD OF | | THE NEW AHU. | | M1201.1SCOPE. | | THE PROVISIONS OF CHAPTERS 12 THROUGH 24 SHALL REGULATE | | THE DESIGN, INSTALLATION, MAINTENANCE, ALTERATION AND | | INSPECTION OF MECHANICAL SYSTEMS THAT ARE PERMANENTLY | | INSTALLED AND USED TO CONTROL ENVIRONMENTAL CONDITIONS | | WITHIN BUILDINGS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-11-05 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-11-05 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-11-05 |
Time |
10:37 |
Sent To |
|
|
Notes |
2019-11-05 10:39:42 | APPROVED FOR PLUMBING FIXTURES ONLY ANY PIPING WORK | | WILL REQUIRE A REVISION TO INCLUDE A FLOOR PLAN AND | | SANITARY ISOMETRIC DRAWING. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-10-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-10-11 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-10-11 |
Time |
15:31 |
Sent To |
|
|
Notes |
2019-10-11 16:53:14 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIALL, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. IT APPEARS THE SCOPE OF THE PLUMBING HAS BEEN | | ENLARGED SHT. 4OF 5 STATES THE SCOPE IS REPLACEMENT OF | | THE FIXTURE BUT IN THE SUBMITTAL PACKAGE I FOUND A 7 X | | 11 SHEET OF PAPER THAT APPEARS TO BE FROM A PLUMBING | | CONTRACTOR STATING THE SCOPE OF THE WORK WAS REPLACING | | THE SEWER AND PIPING TO THE TOILET AND ALSO AL | | UNDERGROUND PIPING SHALL BE CPVC IT IS UNCLEAR EXACTLY | | WHAT IS BEING DONE PLEASE PROVIDE ON THE MAIN PLAN A | | CLEAR AND COMPLETE SCOPE OF PLUMBING WORK, IF THE | | UNDERGROUND SANITARY IS BEING REPLACED PLEASE PROVIDE A | | SANITARY ISOMETRIC. PER WPB AMEND TO FBC ACC | | 107.3.5.3(12) | | | | 2. HOW WILL THE JOB BE COMPLETED WILL THE CONCRETE BE | | CHANNELED OUT IF SO PROVIDE A REPAIR DETAIL IF IT IS A | | TUNNEL JOB PROVIDE A REPORT OF HOW THE HOLE WILL BE | | BACK FILLED TO PROVIDE STRUCTURAL STABILITY FOR THE | | HOUSE. PER WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-08-30 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-08-30 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-08-30 |
Time |
14:33 |
Sent To |
|
|
Notes |
2019-08-30 15:11:59 | 08/30/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
|