Plan Review Details - Permit 19080952
Plan Review Stops For Permit 19080952 |
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-10-21 |
Time |
18:10 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-10-21 |
Time |
18:10 |
Sent To |
|
|
Notes |
2019-10-21 18:11:29 | 10/21/19 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-08-20 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-08-20 |
Time |
15:32 |
Sent To |
|
|
Notes |
2019-08-20 15:33:34 | 08/20/2018 1ST GAS REVIEW **DENIED** WITH COMMENTS | | | | NOTE: A FULL AND COMPREHENSIVE PLAN REVIEW COULD NOT BE | | ACCOMPLISHED AT THIS TIME DUE TO THE QUALITY OF THE | | SUBMITTED PLANS. ADDITIONAL COMMENTS MAY BE GENERATED | | ON THE RESUBMITTAL REVIEW. | | | | 1. THIS TANKLESS UNIT CALL FOR 10.5? WATER COLUMN AND | | THE SERVICE METER DISCHARGES IS A 12? WATER COLUMN | | REQUIRING A REGULATOR FOR THIS UNIT AS PER | | MANUFACTURE?S SPECIFICATION. SUBMIT MANUFACTURER?S | | SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS | | INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE | | APPROVED FOR OUTDOOR INSTALLATION PER THE 2017 FBC RES. | | SEC. G2421.1. | | | | 2. A SUB ELECTRICAL PERMIT IS REQUIRED FOR THE SOURCE | | OF IGNITION, WPB AMENDMENTS TO THE FBC SEC. 105.1. | | | | 3. PLEASE SHOW ON ISOMETRIC ALL REGULATORS AND UNION ON | | REGULATORS / 1? OF EITHER SIDE PER THE 2017 FBC RES | | SEC. G2421.2. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-10-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-10-21 |
Time |
18:10 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-10-21 |
Time |
18:10 |
Sent To |
|
|
Notes |
2019-10-18 11:49:24 | RESUB ROUTED TO LCRESPO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-08-20 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-08-19 |
Time |
12:51 |
Sent To |
|
|
Notes |
2019-08-20 12:51:36 | PLUMB <5K |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-08-20 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-08-20 |
Time |
15:28 |
Sent To |
|
|
Notes |
2019-10-21 18:11:15 | 10/21/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
|