Plan Review Details - Permit 19080951
Plan Review Stops For Permit 19080951
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-09-05 Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-09-05 Cont ID  
Sent By jwitmer Date 2019-09-05 Time 17:22 Rev Time 0.00
Received By jwitmer Date 2019-09-05 Time 17:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-09-11 Cont ID  
Sent By jpearson Date 2019-09-11 Time 08:08 Rev Time 0.00
Received By jpearson Date 2019-09-11 Time 08:08 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-09-06 Cont ID  
Sent By jpearson Date 2019-09-06 Time 11:15 Rev Time 0.00
Received By jpearson Date 2019-09-06 Time 11:09 Sent To I
Notes
2019-09-06 11:15:29CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET
 OF BOTH COPIES) IS REQUIRED TO BEAR THE NAME AND BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. THIS PERSON MUST BE A LICENSED DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER.
 PROVIDE CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481
 2. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP
 CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. IF
 THESE ARE EXISTING, SHOW AS EXISTING. IF NOT EXISTING,
 PROVIDE PER CODE. THE RECEPTACLE OUTLET SHALL BE
 LOCATED ON A WALL OR PARTITION THAT IS ADJACENT TO THE
 BASIN OR BASIN COUNTERTOP, LOCATED ON THE COUNTERTOP,
 OR INSTALLED ON THE SIDE OR FACE OF THE BASIN CABINET.
 PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-08-21 Cont ID  
Sent By pleduc Date 2019-08-21 Time   Rev Time 0.00
Received By pleduc Date 2019-08-21 Time 13:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-12 Cont ID  
Sent By jesmith Date 2019-09-12 Time 10:09 Rev Time 0.00
Received By jesmith Date 2019-09-12 Time 10:09 Sent To  
Notes
2019-09-10 14:31:28RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-09-06 Time   Rev Time 0.00
Received By lmarchan Date 2019-08-19 Time 12:59 Sent To  
Notes
2019-08-20 12:59:40B03

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-09-12 Cont ID  
Sent By jesmith Date 2019-09-12 Time 10:08 Rev Time 0.00
Received By jesmith Date 2019-09-12 Time 09:24 Sent To  
Notes
2019-09-12 10:08:42PLUMBING COMMENTS: APPROVED W/PROVISO
 1. SEE ATTACHED AFFIDAVIT PROVIDED BY OWNER
 ACKNOWLEDGING DEFICIENCY IN FAIR HOUSING ACT AND
 AGREEMENT TO REVERT TO COMPLIANCE AT TIME OF SALE IF
 REQUESTED BY BUYER
 2. SHOWER CONSTRUCTION SHALL COMPLY WITH FBC PLUMBING
 CODE SECTIONS 417.5 THROUGH 417.5.2.6.
 3. ANY NEW THROUGH THE FLOOR PENETRATIONS SHALL MEET
 THE REQUIREMENTS OF FBC CHAPTER 7.
 4. PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE
 AS A DEFERRED SUBMITTAL, UL APPROVED ASSEMBLIES FORANY
 NEW THROUGH THE FLOOR PENETRATIONS FOR META OR PLASTIC
 PIPE AS APPLICABLE. THE DOCUMENTS SHALL BE SUBMITTED,
 APPROVED AND ON SITE PRIOR TO THE FIRST PLUMBING ROUGH
 INSPECTION.
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-08-22 Cont ID  
Sent By jesmith Date 2019-08-22 Time 13:40 Rev Time 0.00
Received By jesmith Date 2019-08-22 Time 13:39 Sent To  
Notes
2019-08-22 13:40:29CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
  
 PLUMBING COMMEMTS: DENIED
 1. UNIT SHALL COMPLY WITH THE FAIR HOUSING ACT. PER
 FWPB FBC 107.2.1, PROVIDE THE FOLLOWING:
 A. IDENTIFY COMPLIANT BATHROOM AS TYPE A, TYPE B, OR
 USABLE POWDER ROOM.
 B. PROVIDE CLEAR FLOOR SPACES FOR USABLE BATHROOM
 FIXTURES AND KITCHEN. REFER TO FAIR HOUSING ACT DESIGN
 MANUAL.
 2. PER WPB FBC 107.2.1, PROVIDE CROSS SECTIONAL DETAIL
 OF MODIFIED SHOWER CONSTRUCTION SHOWING COMPLIANCE WITH
 FBC PL SECTION 4176.
 3. AS THE PLANS ARE NOT SIGNED AND SEALED BY A
 PROFESSIONAL ENGINEER OR ARCHITECT, THE PLUMBING PLAN
 SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE
 DESIGNER PER WPB FBC 107.2.1.
  
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
 AS THE PLANS ARE NOT SIGNED AND SEALED BY A
 PROFESSIONAL ENGINEER OR ARCHITECT, THE PLUMBING PLAN
 SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE
 DESIGNER PER WPB FBC 107.2.1.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19080951 801 S OLIVE AVE 234
  
  
  